Test Procedures - Loads<br />

Water Pump<br />

1. Test using the controller’s indicator lights. Check the indicator light during the freeze cycle.<br />

The light will be On for all but the 30 second anti-slush period, so observe the light for one<br />

minute. When it is On, check the water pump, it should be operating. If not, check voltage to<br />

the pump. If low check the voltage from the controller to ground. The water pump pin is<br />

number 6. If there is voltage at that pin to ground, but very low voltage at the pump motor,<br />

there must be a broken wire in the harness. If the voltage is low at pin 6, the controller should<br />

be replaced.<br />

2. Test using an ohmmeter. Disconnect electrical power. Unplug the water pump motor leads<br />

from the harness. Measure the resistance of the motor windings. If open, replace the pump.<br />

Measure resistance to ground. If there is any, replace the pump.<br />

Water pump light is ON when<br />

pump is in operation.<br />