HUWILIFT E-VERSO – FAQ & TECHNICAL DATA<br />
FAQ<br />
Frequently asked questions<br />
What s<strong>up</strong>ply voltage do the E-fittings need?<br />
With input voltage between 100-240 V, the E-fittings can be used anywhere in the world.<br />
Note: The device adapts to voltage peaks.<br />
What happens if the power s<strong>up</strong>ply is interr<strong>up</strong>ted?<br />
If this happens, the doors can be opened by h<strong>and</strong>. When power is restored, system operation is resumed by simply<br />
pressing the remote control. The first opening <strong>and</strong> closing movements will again be learning movements to reprogram<br />
the final open <strong>and</strong> shut positions respectively.<br />
Must the remote control always be attached to the c<strong>up</strong>board with electric operation?<br />
No, it must merely be close to the c<strong>up</strong>board.<br />
Is there any risk of injury when the doors are operated electrically?<br />
No, because the motor switches off immediately if an obstacle is encountered during an opening or closing movement.<br />
Does the system need regular adjusting or oiling?<br />
No, E-fittings are maintenance free.<br />
What should I do if there’s an operating problem?<br />
First consult the troubleshooting section of the operating instructions to check whether you can identify the cause of the<br />
problem <strong>and</strong> fix it. Only if you can’t get the system operating again should you contact your furniture s<strong>up</strong>plier or manufacturer<br />
who will take all the necessary steps.<br />
Technical data<br />
Device name, control unit<br />
Device name, remote control<br />
S<strong>up</strong>ply voltage<br />
Input power<br />
Output power<br />
Ambient operating temperature<br />
Overvoltage category<br />
Protection class<br />
Contamination level<br />
Radio frequency<br />
Transmitter power<br />
Battery<br />
St<strong>and</strong>by power<br />
Operating note<br />
DSB 899 A<br />
DSB 899 C<br />
100-240 V~/ 50-60 Hz<br />
≤ 50 W<br />
≤ 50 W<br />
0-40°C / 32-104°F<br />
II<br />
2<br />
IP 2<br />
EU 869.00 MHz / US 915.00 MHz<br />
40 μW<br />
Lithium button cell CR2032<br />
0.6 W<br />
After 2 minutes continuous operation – 8 minutes non-operational<br />