Torque transducer Data sheet
Torque transducer Data sheet
Torque transducer Data sheet
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Specifications (continued)<br />
Nominal (rated) torque M nom N⋅m 5 10 20 50 100 200 500<br />
kN⋅m 1<br />
General data<br />
EMC 2)<br />
Immunity from interference<br />
(DIN EN 61326−1 / EN 61000−6)<br />
Enclosure<br />
HF line interference<br />
150 kHZ − 80 MHz (AM)<br />
ESD (electrostatic discharge)<br />
Enclosure<br />
Electromagnetic field<br />
80 MHz − 1000 MHz (AM)<br />
1400 MHz − 2700 MHz (AM)<br />
V<br />
kV<br />
kV<br />
V/m<br />
V/m<br />
10 / A<br />
Air 8 / A<br />
Contact 4 / A<br />
10 / A<br />
3 / A<br />
Lines − Connecting cable<br />
Burst (fast transients) kV 2 / A<br />
Emission (EME) (EN 61326-1 / EN 55011)<br />
RFI voltage<br />
(interference voltage at DC mains connection)<br />
RFI field strength<br />
−<br />
−<br />
Class B (150 kHz − 30 MHz)<br />
Class B (30 MHz − 1000 MHz)<br />
(Electromagnetic RFI field strength)<br />
Degree of protection per EN 60529 IP 40<br />
Nominal (rated) temperature range °C [°F] +5...+45 [+41...+113]<br />
Operating temperature range °C [°F] 0...+60 [+32...+140]<br />
Storage temperature range °C [°F] −5...+70 [+23...+158]<br />
Impact resistance, test severity level per<br />
DIN IEC 68; Part 2-27; IEC 68-2-29-1987<br />
number n 1000<br />
duration ms 3<br />
acceleration (halfsine) m/s 2 650<br />
Vibration resistance, test severity level<br />
per DIN IEC 68, Part 2-6: IEC 68-2-6-1982<br />
frequency range Hz 5 ... 65<br />
duration h 1.5<br />
acceleration (amplitude) m/s 2 50<br />
Nominal (rated) rotational speed n nom min -1 16 000 12 000 9 000<br />
Load limits 3)<br />
Limit torque, related to M nom % 200 5)<br />
Breaking torque, related to M nom % > 280<br />
Longitudinal limit force kN 0.9 0.9 0.9 1.6 1.6 1.6 4 4<br />
Lateral limit force N 25 45 90 210 420 850 1400 2800<br />
Bending limit moment N⋅m 0.5 0.9 1.9 5.5 11 22 54 109<br />
Oscillation width per DIN 50100 (peak-topeak)<br />
4) %<br />
80<br />
2) Test severity / criterion: Industrial environment, cable length 30 m. Application not outside buildings.<br />
3) Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal (rated) torque) can only be permitted up to its<br />
specified static load limit provided none of the others can occur at the same time. If this condition is not met, the limit values must be<br />
reduced. If 30% of the bending limit moment and lateral limit force occur at the same time, only 40% of the longitudinal limit force is<br />
permissible and the nominal (rated) torque must not be exceeded. The permissible bending moments, longitudinal forces and lateral forces<br />
can affect the measurement result by approx. 1 % of the nominal (rated) torque.<br />
4) The nominal (rated) torque must not be exceeded.<br />
5) Please adhere to the maximum torque (T max ) of the couplings.<br />
B2318-2.0 en<br />
3<br />
HBM