Protection classes · Safety classes<br />

Our statements concerning the resistance <strong>of</strong> our luminaires against the penetration <strong>of</strong> dust,<br />

solid foreign bodies and water are made according to EN 60598/ VDE 0711.<br />

The respective degree <strong>of</strong> protection IP (International Protection) is marked by an IP<br />

number system according to IEC 529.<br />

Please see the table on this page for classification <strong>of</strong> the degree <strong>of</strong> protection according to<br />

EN 60598.<br />

Protection classes<br />

1st digit: foreign body protection<br />

5<br />

6<br />

7<br />

8<br />

4<br />

44<br />

IP 1X against foreign bodies ≥ 50 mm<br />

IP 2X against foreign bodies ≥ 12 mm<br />

IP 3X against foreign bodies ≥ 2.5 mm<br />

IP 4X against foreign bodies ≥ 1mm<br />

IP 5X against dust<br />

IP 6X dustpro<strong>of</strong><br />

2nd digit: water protection<br />

IP X1 against vertical drops <strong>of</strong> water<br />

IP X2 against sloping drops <strong>of</strong> water up to an angle <strong>of</strong> 15°<br />

IP X3 against spray water up to an angle <strong>of</strong> 60°<br />

IP X4<br />

IP X5<br />

against splash water<br />

against jet water<br />

Safety classes<br />

1<br />

2<br />

3<br />

Safety class I distinguishes luminaires with an earth connection. Under<br />

faulty conditions, the power supply is cut <strong>of</strong>f by an overload device.<br />

Safety class II distinguishes luminaires that, apart from functional<br />

insulation, are provided with additional protective insulation.<br />

Under faulty conditions, no dangerous voltage can reach metal parts<br />

which can be touched. Many luminaires are available in Safety<br />

class I and also in Safety class II. Please enquire accordingly.<br />

Safety class III distinguishes luminaires operating on extra-low safety<br />

voltage. They can only be connected to safety transformers<br />

according to EN 61558/VDE 0<strong>57</strong>0, EN 61347/VDE 712 or VDE 0100<br />

Part 410. Transformers must be approved for the type <strong>of</strong> installation.<br />