<strong>Kitsap</strong> <strong>Public</strong> <strong>Health</strong> <strong>District</strong><br />

Pollution Source Identification and Correction: <strong>Protocol</strong> <strong>Manual</strong><br />

• Retrieve optical brightener pads after one week of placement, briefly rinse in water flow,<br />

• squeeze out excess water (do not wring), and place in new re-sealable plastic bag. Label bag<br />

with sampling station, date and time sampler was placed and recovered. Do not put any label or<br />

used anchoring wire inside the bag. Use a permanent black pen to label the bag.<br />

• Refrigerate or freeze the optical brightener pads until shipment.<br />

The pads do not need to shipped overnight, but it is advisable to ship them so that arrive within a few<br />

business days. Include the chain of custody form from OUL along with a letter requesting sample<br />

analysis.<br />

FLUOROMETER<br />

The fluorometer is used for both optical brighteners and fluorescein dye. Instructions for the calibration<br />

and use of the fluorometer are found in the lab with the unit.<br />