Pollution Source Identification and Correction: <strong>Protocol</strong> <strong>Manual</strong><br />
• Retrieve optical brightener pads after one week of placement, briefly rinse in water flow,<br />
• squeeze out excess water (do not wring), and place in new re-sealable plastic bag. Label bag<br />
with sampling station, date and time sampler was placed and recovered. Do not put any label or<br />
used anchoring wire inside the bag. Use a permanent black pen to label the bag.<br />
• Refrigerate or freeze the optical brightener pads until shipment.<br />
The pads do not need to shipped overnight, but it is advisable to ship them so that arrive within a few<br />
business days. Include the chain of custody form from OUL along with a letter requesting sample<br />
analysis.<br />
FLUOROMETER<br />
The fluorometer is used for both optical brighteners and fluorescein dye. Instructions for the calibration<br />
and use of the fluorometer are found in the lab with the unit.<br />