Bi-flow filter drier with flare and cu-plated solder connectors, type DMB/DCB<br />
<strong>Co</strong>nstruction /<br />
flow direction<br />
Capacities<br />
SI units<br />
Liquid capacity (DMB/DCB)<br />
Type<br />
Liquid capacity in kW at pressure drop<br />
∆p = 0.07 bar 1 )<br />
R 134a R 404A / R 507 R 22 / R 407C / R 410A<br />
DMB/DCB 082 / 082s 3.9 2.8 4.3<br />
DMB/DCB 083 / 083s 7.4 5.3 8.2<br />
DMB/DCB 084 / 084s 8.3 6.0 9.2<br />
DMB/DCB 162 7.6 5.3 8.8<br />
DMB/DCB 163 / 163s 18 13 20<br />
DMB/DCB 164 / 164s 28 20 32<br />
DMB/DCB 165 / 165s 37 29 40<br />
DMB/DCB 303 / 303s 19 15 21<br />
DMB/DCB 304 / 304s 28 20 31<br />
DMB/DCB 305 / 305s 38 28 42<br />
DMB/DCB 307s 43 32 47<br />
1 ) Capacity given in accordance with ARI 710-86<br />
(t e = −15°C, t c = +30°C)<br />
US units<br />
Liquid capacity (DMB/DCB)<br />
Type<br />
Liquid capacity in Tons at pressure drop<br />
∆p = 1.02 psig 1 )<br />
R 134a R 404A / R 507 R 22 / R 407C / R 410A<br />
DMB/DCB 082 / 082s 1.1 0.8 1.2<br />
DMB/DCB 083 / 083s 2.1 1.5 2.3<br />
DMB/DCB 084 / 084s 2.4 1.7 2.6<br />
DMB/DCB 162 2.2 1.5 2.5<br />
DMB/DCB 163 / 163s 5.1 3.7 5.7<br />
DMB/DCB 164 / 164s 8.0 5.7 9.1<br />
DMB/DCB 165 / 165s 10.6 8.3 11.4<br />
DMB/DCB 303 / 303s 5.4 4.3 6.0<br />
DMB/DCB 304 / 304s 8.0 5.7 8.9<br />
DMB/DCB 305 / 305s 10.9 8.0 12.0<br />
DMB/DCB 307s 12.3 9.1 13.4<br />
1 ) Capacity given in accordance with ARI 710-86<br />
(t e = +5°F, t c = +86°F)<br />
20 Technical leaflet - RD6AP102 © Danfoss A/S (RC-CM / MWA), 06 - 2002