23.03.2014 Views

Line components Contents Page - Erawan Refrigeration Co., Ltd.

Line components Contents Page - Erawan Refrigeration Co., Ltd.

Line components Contents Page - Erawan Refrigeration Co., Ltd.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Bi-flow filter drier with flare and cu-plated solder connectors, type DMB/DCB<br />

Selection example<br />

Select the appropriate type (DMB or DCB) based<br />

on refrigerant and oil type. Then select the drier<br />

size based on the adsorption and liquid capacity<br />

required.<br />

a. Amount of charge: 15 kg R 134a at t L = 24°C<br />

To dry 15 kg R 134a at 24°C from 1050 to<br />

60 ppm moisture, a DMB 16 is necessary.<br />

b. <strong>Co</strong>oling capacity: Q e = 25 kW<br />

To obtain a mass flow corresponding to 25 kW<br />

cooling capacity with a DMB 16 filter drier, a<br />

1<br />

/ 2 inch connection must be chosen.<br />

Larger connections can be chosen in<br />

accordance with the liquid line dimension.<br />

c. Result<br />

DMB 164 or DMB 165 can be used.<br />

If the initial moisture content is very small or a<br />

planned change of the filter drier is considered, a<br />

smaller filter drier size can be chosen.<br />

Drying capacity (DMB)<br />

Type<br />

Drying capacity in kg of refrigerant<br />

R 134 a R 404A R 407C R 22<br />

R 507<br />

R 410A<br />

24°C 52°C 24°C 52°C 24°C 52°C 24°C 52°C<br />

DMB 082 / 082s<br />

DMB 083 / 083s 9.2 8.5 8.7 8.1 8.0 7.3 8.7 8.0<br />

DMB 084 / 084s<br />

DMB 162<br />

DMB 163 / 163s<br />

DMB 164 / 164s 17.8 16.5 16.8 15.7 15.4 14.1 16.8 15.6<br />

DMB 165 / 165s<br />

DMB 303 / 303s<br />

DMB 304 / 304s<br />

DMB 305 / 305s<br />

43.5 40.4 41.0 38.4 37.8 34.6 41.2 38.1<br />

DMB 307s<br />

Liquid capacity (DMB/DCB)<br />

Type<br />

Liquid capacity in kW at pressure drop<br />

∆p = 0.07 bar 1 )<br />

R 134a R 404A / R 507 R 22 / R 407C / R 410A<br />

DMB/DCB 162 7.6 5.3 8.8<br />

DMB/DCB 163 / 163s 18 13 20<br />

DMB/DCB 164 / 164s 28 20 32<br />

DMB/DCB 165 / 165s 37 29 40<br />

DMB/DCB 303 / 303s 19 15 21<br />

DMB/DCB 304 / 304s 28 20 31<br />

DMB/DCB 305 / 305s 38 28 42<br />

DMB/DCB 307s 43 32 47<br />

22 Technical leaflet - RD6AP102 © Danfoss A/S (RC-CM / MWA), 06 - 2002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!