Ordering data Probes tes<strong>to</strong> 6610<br />

0555 6610 Lxx Mxx<br />

Nxx<br />

Pxx<br />

L11<br />

L12<br />

L13<br />

L14<br />

L15<br />

L17<br />

Probe 6611 (wall version)<br />

Probe 6612 (duct version <strong>to</strong> 150 °C)<br />

Probe 6613 (cable version <strong>to</strong> 180 °C)<br />

Probe 6614 (heated cable version)<br />

Probe 6615 (trace humidity cable version)<br />

Probe 6617 (self-moni<strong>to</strong>red cable version)<br />

Order example for tes<strong>to</strong> 6613 probe<br />

Cable probe, -40 <strong>to</strong> +180 °C<br />

Sintered stainless steel filter<br />

Cable l<strong>en</strong>gth 2 m<br />

Probe l<strong>en</strong>gth 300 mm<br />

M01<br />

M02<br />

M03<br />

M04<br />

M06<br />

M07<br />

M08<br />

Sintered stainless steel filter<br />

Wire mesh protective cap<br />

Sintered Teflon filter<br />

Metal protective cap, op<strong>en</strong><br />

Teflon filter with drip hole<br />

Teflon filter w. drip hole a. cond<strong>en</strong>sation protection<br />

Filter for H 2<br />

O 2<br />

<strong>en</strong>vironm<strong>en</strong>ts**<br />

0555 6610 L13 / M01 / N02 / P30<br />

specially for high humidity<br />

N00<br />

N01<br />

N02<br />

N05<br />

N10<br />

N23<br />

Without cable<br />

Cable l<strong>en</strong>gth 1 m<br />

Cable l<strong>en</strong>gth 2 m<br />

Cable l<strong>en</strong>gth 5 m<br />

Cable l<strong>en</strong>gth 10 m<br />

Cable l<strong>en</strong>gth, specially for duct versions<br />

L11 L12 L13 L14 L15 L17<br />

X – – – – –<br />

– – X X X X<br />

– – X X X X<br />

– – X X X X<br />

– – X X X X<br />

– X – – – –<br />

P07<br />

P14<br />

P20<br />

P30<br />

P50<br />

P80<br />

Probe l<strong>en</strong>gth 70 mm<br />

Probe l<strong>en</strong>gth 120 mm<br />

Probe l<strong>en</strong>gth 200 mm<br />

Probe l<strong>en</strong>gth 300 mm<br />

Probe l<strong>en</strong>gth 500 mm<br />

Probe l<strong>en</strong>gth 800 mm<br />

L11 L12 L13 L14 L15 L17<br />

X – – – –<br />

– – X – – –<br />

X X X X X X<br />

– X X – – –<br />

– X X X X X<br />

– X X – – –<br />

Ordering procedure:<br />

Transmitters and probes can be ordered indep<strong>en</strong>d<strong>en</strong>tly of each o<strong>the</strong>r, (on account of <strong>the</strong> digital probe interface), cf. order examples above.<br />

If <strong>the</strong> transmitter and probe order are <strong>to</strong> be assembled <strong>to</strong>ge<strong>the</strong>r, <strong>the</strong>ir order codes are combined in <strong>the</strong> distribution set 0563 6651<br />

**H2O2 processes:<br />

With tes<strong>to</strong> 6681, Tes<strong>to</strong> offers a transmitter which can also be used in hydrog<strong>en</strong> peroxide processes (H2O2) – for example in sterilization. The<br />

s<strong>en</strong>sor is protected with <strong>the</strong> help of a special probe (Code M08). The so-called “mixture dewpoint” °Ctm/°Ftm is also displayed.<br />