<strong>Committing</strong> <strong>to</strong> <strong>the</strong> <strong>future</strong><br />
tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681 with E<strong>the</strong>rnet module<br />
Connect your humidity transmitter over E<strong>the</strong>rnet:<br />
Measurem<strong>en</strong>t data moni<strong>to</strong>ring parallel <strong>to</strong> control<br />
Start Edit Options Template<br />
Number field<br />
Copy Op<strong>en</strong><br />
Paste<br />
R<strong>en</strong>ame<br />
Close<br />
Clipboard<br />
Organizing<br />
Delete<br />
Online<br />
Offline<br />
Online start<br />
Data<br />
Data<br />
Edit<br />
Group 0<br />
Online s<strong>to</strong>p<br />
Control measurem<strong>en</strong>t<br />
Operating mode Online<br />
Day<br />
Month<br />
Diagram<br />
His<strong>to</strong>gram<br />
Graphic<br />
Group 0<br />
°C<br />
°C<br />
°C<br />
Group 1<br />
Evaluation<br />
Number field<br />
View<br />
Table<br />
Alarms<br />
°C<br />
°C<br />
21 °C<br />
48 %RH<br />
M T W T F S S<br />
41 °C<br />
22 %RH<br />
Data<br />
M T W T F S S<br />
Alarms<br />
26 °C<br />
38 %RH<br />
December 2007<br />
M T W T F S S<br />
Today
Humidity transmitter with E<strong>the</strong>rnet – Your b<strong>en</strong>efits at a glance<br />
E<strong>the</strong>rnet finally also for humidity transmitters<br />
Tes<strong>to</strong>, as <strong>the</strong> first supplier worldwide of humidity measurem<strong>en</strong>t<br />
technology, offers an E<strong>the</strong>rnet interface for humidity transmitters.<br />
Now, parallel <strong>to</strong> <strong>the</strong> use of analog outputs for regulation purposes,<br />
integrated measurem<strong>en</strong>t data moni<strong>to</strong>ring from <strong>the</strong> <strong>the</strong> field <strong>to</strong><br />
managem<strong>en</strong>t level (e.g. data from production available in <strong>the</strong> office) is<br />
made possible easily, effici<strong>en</strong>tly and at a competitive price.<br />
E<strong>the</strong>rnet is preval<strong>en</strong>t in almost all office networks so that installation<br />
work is kept <strong>to</strong> a minimum wh<strong>en</strong> <strong>the</strong> humidity transmitter is<br />
connected <strong>to</strong> <strong>the</strong> network structures already in exist<strong>en</strong>ce.<br />
The new tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681 humidity transmitter g<strong>en</strong>eration is<br />
designed for process moni<strong>to</strong>ring in HVAC, process and compressed<br />
air technology. With solutions for highest accuracy as well as for<br />
special applications (high humidity, H 2<br />
O 2<br />
sterilisation processes, trace<br />
humidity applications, etc.) unrivalled cutting edge technology is<br />
available for measuring humidity.<br />
Developed for practical use<br />
The E<strong>the</strong>rnet module is an “intermediate layer” (sandwich design)<br />
which is already built in<strong>to</strong> <strong>the</strong> tes<strong>to</strong> 6651 and 6681 transmitters in <strong>the</strong><br />
fac<strong>to</strong>ry. It can also be subsequ<strong>en</strong>tly easily and quickly retrofitted on<br />
site.<br />
Two LEDs signal <strong>the</strong> status of <strong>the</strong> power and LAN connection <strong>to</strong> <strong>the</strong><br />
system opera<strong>to</strong>r responsible.<br />
By using an E<strong>the</strong>rnet plug suitable for industry, IP65 housing<br />
protection can be guaranteed so that <strong>the</strong> transmitter withstands <strong>the</strong><br />
sometimes <strong>to</strong>ugh and demanding conditions of industrial processes.<br />
E<strong>the</strong>rnet module<br />
(intermediate layer)<br />
Process reliability and time saved by measurem<strong>en</strong>t data moni<strong>to</strong>ring<br />
Networking transmitters using E<strong>the</strong>rnet provides considerable b<strong>en</strong>efits in a number of applications such as for moni<strong>to</strong>ring labora<strong>to</strong>ries,<br />
warehouses, production rooms, cleanrooms or drying systems. In addition <strong>to</strong> transmitting <strong>the</strong> readings signals by analog outputs <strong>to</strong> a control<br />
system, measurem<strong>en</strong>t data can also be simultaneously recorded, docum<strong>en</strong>ted and visualised using E<strong>the</strong>rnet. If necessary, it is also possible <strong>to</strong><br />
alert <strong>the</strong> person responsible for <strong>the</strong> process.<br />
Easy <strong>to</strong> install<br />
High transmission speed<br />
Consist<strong>en</strong>cy of data<br />
=> High accuracy level since<br />
no signal conversion is<br />
needed<br />
E<strong>the</strong>rnet<br />
Preval<strong>en</strong>t in almost all office<br />
networks<br />
⇒ Integration of transmitters in<br />
network structures available means<br />
lower installation costs<br />
⇒ Continuous data flow from field<br />
<strong>to</strong> managem<strong>en</strong>t level,<br />
e.g. data from production available<br />
in office<br />
Online moni<strong>to</strong>ring parallel <strong>to</strong><br />
control/regulation<br />
2<br />
Data transmission over wide distances<br />
makes remote inquiries possible<br />
Networks with a large number of<br />
networking participants
Measurem<strong>en</strong>t data moni<strong>to</strong>ring using E<strong>the</strong>rnet<br />
Overview of tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681 product line<br />
Process requirem<strong>en</strong>t<br />
The tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681 humidity transmitter<br />
g<strong>en</strong>eration stands out on account of a number of world<br />
innovations which provide for a reliable and servicefri<strong>en</strong>dly<br />
application which in turn means highest effici<strong>en</strong>cy<br />
levels and process reliability:<br />
– Replaceable, digital probes<br />
– Early warning system and self-moni<strong>to</strong>ring (prev<strong>en</strong>tive<br />
maint<strong>en</strong>ance)<br />
– Versatile adjustm<strong>en</strong>t options<br />
– Integrated log <strong>to</strong> save parameterization, adjustm<strong>en</strong>t and<br />
message his<strong>to</strong>ry<br />
– Optional relay outputs<br />
You will find more detailed information about <strong>the</strong>se<br />
products in <strong>the</strong> Catalogue: “Stationary Measurem<strong>en</strong>t<br />
Solutions for HVAC and Process”.<br />
Application areas<br />
tes<strong>to</strong> 6651 + E<strong>the</strong>rnet module<br />
HVAC and industry:<br />
Critical climate, cleanrooms<br />
tes<strong>to</strong> 6681 + E<strong>the</strong>rnet module<br />
Industry:<br />
Critical climate, cleanrooms, drying<br />
processes, high humidity, trace<br />
humidity, humidity in H 2<br />
O 2<br />
<strong>en</strong>vironm<strong>en</strong>t etc.<br />
tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681 transmitters as well as digital tes<strong>to</strong> 6600 and tes<strong>to</strong> 6610 probes<br />
Deciding on tes<strong>to</strong> 6651 or tes<strong>to</strong> 6681 dep<strong>en</strong>ds mainly on <strong>the</strong> probe options in addition <strong>to</strong> <strong>the</strong> question about housing material (tes<strong>to</strong> 6681:<br />
metal housing) and <strong>the</strong> humidity parameters <strong>to</strong> be used. In <strong>the</strong> case of both transmitters, an E<strong>the</strong>rnet module is available as an option.<br />
Wall Duct Cable<br />
Standard<br />
±1 %RH ±1.7 %RH ±1 %RH ±1.7 %RH ±1 %RH ±1.7 %RH<br />
For<br />
high<br />
humidity<br />
–> heated<br />
For<br />
trace<br />
humidity<br />
–> with<br />
au<strong>to</strong>adjust<br />
Security<br />
–> au<strong>to</strong>diagnosis<br />
at <strong>the</strong><br />
s<strong>en</strong>sor<br />
-20 <strong>to</strong> +70 °C<br />
-4 <strong>to</strong> +158 °F<br />
-20 <strong>to</strong> +70 °C<br />
-4 <strong>to</strong> +158 °F<br />
-20 <strong>to</strong> +120 °C<br />
-4 <strong>to</strong> +248 °F<br />
-40 <strong>to</strong> +180 °C<br />
-40 <strong>to</strong> +356 °F<br />
-20 <strong>to</strong> +70 °C<br />
-4 <strong>to</strong> +158 °F<br />
-20 <strong>to</strong> +120 °C<br />
-4 <strong>to</strong> +248 °F<br />
6601 6602 6603 6604 6605<br />
-60 <strong>to</strong> +30<br />
°C tpd<br />
Probes for tes<strong>to</strong> 6651 (tes<strong>to</strong> 6600)<br />
±1.2 %RH<br />
-20 <strong>to</strong> +70 °C<br />
-4 <strong>to</strong> +158 °F<br />
-30 <strong>to</strong> +150 °C<br />
-22 <strong>to</strong> +302 °F<br />
-40 <strong>to</strong> +180 °C<br />
-40 <strong>to</strong> +356 °F<br />
-40 <strong>to</strong> +180 °C<br />
-40 <strong>to</strong> +356 °F<br />
6611 6612<br />
6613 6614 6615 6617<br />
Probes for tes<strong>to</strong> 6681 (tes<strong>to</strong> 6610)<br />
3
1. Measurem<strong>en</strong>t data moni<strong>to</strong>ring using tes<strong>to</strong> Saveris TM and humidity transmitter<br />
The E<strong>the</strong>rnet module with tes<strong>to</strong> 6651and<br />
tes<strong>to</strong> 6681 transmitters can be operated in<br />
two modes:<br />
1. Integration of transmitter in <strong>the</strong> tes<strong>to</strong><br />
Saveris measurem<strong>en</strong>t data moni<strong>to</strong>ring<br />
system<br />
2. Integration of transmitter in cus<strong>to</strong>mer’s<br />
moni<strong>to</strong>ring system (op<strong>en</strong> log)<br />
1. tes<strong>to</strong> Saveris now fit for all humidity<br />
applications<br />
If <strong>the</strong> E<strong>the</strong>rnet module is operated in <strong>the</strong> tes<strong>to</strong><br />
Saveris mode, tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681<br />
transmitters can be easily implem<strong>en</strong>ted in <strong>the</strong><br />
tes<strong>to</strong> Saveris measurem<strong>en</strong>t data moni<strong>to</strong>ring<br />
system. In addition <strong>to</strong> actual measurem<strong>en</strong>t<br />
data docum<strong>en</strong>tation and visualisation using<br />
tes<strong>to</strong> Saveris software, <strong>the</strong>re is also <strong>the</strong><br />
option of notifying <strong>the</strong> person responsible for<br />
<strong>the</strong> system if limits are exceeded.<br />
In this operating mode, <strong>the</strong> transmitter has an<br />
internal data s<strong>to</strong>re which prev<strong>en</strong>ts data from<br />
getting lost if <strong>the</strong> LAN connection breaks<br />
down. All of <strong>the</strong> humidity parameters (e.g.<br />
%RH, g/m³, g/kg, ppm, etc.) can be<br />
transmitted. The transmitter is parameterised<br />
using P2A software or <strong>the</strong> transmitter’s<br />
operating m<strong>en</strong>u.<br />
While moni<strong>to</strong>ring using tes<strong>to</strong> Saveris, PLC<br />
control (if required) is possible with <strong>the</strong><br />
transmitters.<br />
In addition <strong>to</strong> <strong>the</strong> tes<strong>to</strong> 6681 transmitter<br />
humidity probes, <strong>the</strong>re are now also probes<br />
available for special applications such as high<br />
humidity, trace humidity, corrosive<br />
substances or H 2<br />
O 2<br />
atmospheres. The probe<br />
options also facilitate direct installation on<br />
ducts as well as <strong>the</strong> moni<strong>to</strong>ring of processes<br />
<strong>to</strong> 180 °C using cable probes.<br />
Transmitter<br />
Memory for s<strong>to</strong>ring<br />
data,<br />
24 VDC/AC power<br />
PLC<br />
Control/Regulation<br />
In addition <strong>to</strong> operating<br />
in <strong>the</strong> Saveris system,<br />
analog outputs can be<br />
used simultaneously for<br />
control<br />
tes<strong>to</strong> 6681/tes<strong>to</strong> 6651 +<br />
E<strong>the</strong>rnet module<br />
Analog signals,<br />
e.g. 4 <strong>to</strong> 20 mA<br />
E<strong>the</strong>rnet<br />
Up <strong>to</strong> 127<br />
transmitters can be<br />
integrated in a<br />
Saveris system (2<br />
channels per<br />
transmitter)<br />
tes<strong>to</strong> 6681/tes<strong>to</strong> 6651:<br />
Measurem<strong>en</strong>t data is logged and transmitted <strong>to</strong> tes<strong>to</strong> Saveris/PLC<br />
4
Measurem<strong>en</strong>t data moni<strong>to</strong>ring using tes<strong>to</strong> Saveris TM and humidity transmitter<br />
tes<strong>to</strong> Saveris base<br />
The base is <strong>the</strong> heart of <strong>the</strong> tes<strong>to</strong> Saveris measurem<strong>en</strong>t<br />
data moni<strong>to</strong>ring system and can save 40,000 readings<br />
per measurem<strong>en</strong>t channel indep<strong>en</strong>d<strong>en</strong>tly of your PC.<br />
Readings, system data and alarms can be called up on<br />
<strong>the</strong> Saveris base display.<br />
tes<strong>to</strong> Saveris software<br />
tes<strong>to</strong> Saveris software is easy <strong>to</strong> use and has an intuitive<br />
user interface. Saveris software is available in two differ<strong>en</strong>t<br />
versions: SBE (Small Business Edition) or PROF<br />
(Professional) software version with diverse additional<br />
options. If external access <strong>to</strong> <strong>the</strong> measurem<strong>en</strong>t data is<br />
required from outside, Internet access can be set up <strong>to</strong><br />
display all measurem<strong>en</strong>t data.<br />
Probes<br />
Registration<br />
Router<br />
Converter<br />
tes<strong>to</strong> Saveris software<br />
Docum<strong>en</strong>tation of values =<br />
“Database”<br />
Visualisation<br />
Notification by email<br />
tes<strong>to</strong> Saveris base<br />
E<strong>the</strong>rnet<br />
Data acquisition and<br />
transmission <strong>to</strong> PC<br />
Alarm options (text<br />
message, relay, LED)<br />
Emerg<strong>en</strong>cy battery for<br />
power outage<br />
E<strong>the</strong>rnet<br />
tes<strong>to</strong> Saveris wireless<br />
probe<br />
Memory for s<strong>to</strong>ring data<br />
tes<strong>to</strong> Saveris E<strong>the</strong>rnet probes for far away<br />
sites<br />
Memory for s<strong>to</strong>ring data<br />
In addition <strong>to</strong> transmitters probes are used for<br />
moni<strong>to</strong>ring jobs and are connected <strong>to</strong> <strong>the</strong><br />
E<strong>the</strong>rnet module but do not have analog<br />
outputs available for regulation/control over<br />
PLC.<br />
Probes with wireless transmission, internal as<br />
well as external temperature s<strong>en</strong>sors and<br />
humidity s<strong>en</strong>sors can be easily implem<strong>en</strong>ted<br />
for moni<strong>to</strong>ring jobs (without control).<br />
tes<strong>to</strong> Saveris:<br />
Measurem<strong>en</strong>t data moni<strong>to</strong>ring<br />
More information at www.tes<strong>to</strong>-international.com/saveris or in <strong>the</strong> “Measurem<strong>en</strong>t, Docum<strong>en</strong>tation, Alarm” Catalogue<br />
5
2. Humidity transmitter in cus<strong>to</strong>mer’s system<br />
2. Integration of transmitter in cus<strong>to</strong>mer’s system<br />
If <strong>the</strong> “Supplied by cus<strong>to</strong>mer” operating mode is selected in <strong>the</strong> transmitter’s E<strong>the</strong>rnet module, <strong>the</strong> intermediate layer functions as<br />
an XML server. Data is transmitted as an XML data set. Simple integration in<strong>to</strong> <strong>the</strong> user’s system is possible on account of <strong>the</strong><br />
disclosed log.<br />
Parameterizations, analyses/tests and queries about <strong>the</strong> his<strong>to</strong>ry data in <strong>the</strong> transmitter can be carried out or called up using<br />
E<strong>the</strong>rnet (data sets) “from above” (using your PC).<br />
e.g. test stand software<br />
Online logging<br />
Docum<strong>en</strong>tation<br />
Visualisation<br />
Alarm<br />
– Readings (2–3 channels)<br />
– Serial number<br />
– SEPARATE warning, error and status messages<br />
– Transmitter his<strong>to</strong>ries<br />
E<strong>the</strong>rnet<br />
Complete parameter set “from above”, i.e. all<br />
functions of P2A software<br />
– Parameterization<br />
– Test/Analysis: Query about operating hours<br />
counter, test relay etc.<br />
tes<strong>to</strong> 6651/tes<strong>to</strong> 6681<br />
with E<strong>the</strong>rnet<br />
e.g. 4 <strong>to</strong> 20 mA<br />
Data transmission as XML data set<br />
Disclosed log<br />
Control<br />
Regulation<br />
– Easy integration in cus<strong>to</strong>mer’s systems<br />
– No password, no coding<br />
Technical data / Ordering data E<strong>the</strong>rnet module<br />
Upgrade module Optional E<strong>the</strong>rnet module for Optional E<strong>the</strong>rnet module for<br />
E<strong>the</strong>rnet intermediate layer tes<strong>to</strong> 6651 tes<strong>to</strong> 6681<br />
Interface<br />
Oper. temp.<br />
RJ45 (E<strong>the</strong>rnet 10BatesT / 100 Base TX)<br />
-20 <strong>to</strong> +70 °C<br />
Oper. humidity<br />
0 <strong>to</strong> 100 %RH<br />
S<strong>to</strong>rage temp. -40 <strong>to</strong> +80 °C<br />
Status LEDs (gre<strong>en</strong>)<br />
Power LED / LAN connection status<br />
Housing colour<br />
Metallic<br />
Grey<br />
Metallic<br />
Material/Housing Metal<br />
Plastic<br />
Metal<br />
Part no.<br />
0554 6656<br />
Order code E01 c.f. P. 7 Order code E01 c.f. P. 9<br />
6
Ordering data for tes<strong>to</strong> 6651 humidity transmitter and tes<strong>to</strong> 6600 humidity probes<br />
0555 6651 A01 Bxx<br />
Cxx Dxx Exx Fxx Gxx Hxx Ixx Jxx Kxx<br />
B02<br />
B03<br />
B04<br />
B05<br />
B06<br />
0 <strong>to</strong> 1 V (4-wire, 24 VAC/DC)<br />
0 <strong>to</strong> 5 V (4-wire, 24 VAC/DC)<br />
0 <strong>to</strong> 10 V (4-wire, 24 VAC/DC)<br />
0 <strong>to</strong> 20 mA (4-wire, 24 VAC/DC)<br />
4 <strong>to</strong> 20 mA (4-wire, 24 VAC/DC)<br />
F01<br />
F02<br />
F03<br />
F04<br />
F05<br />
%RH / min / max<br />
°C / min / max<br />
°F / min / max<br />
°C td<br />
/ min / max<br />
°F td<br />
/ min / max<br />
Channel 1*<br />
C00<br />
C02<br />
C03<br />
C04<br />
C05<br />
C06<br />
C07<br />
D01<br />
D02<br />
D03<br />
E00<br />
E01<br />
Without display<br />
With display / English<br />
With display / German<br />
With display / Fr<strong>en</strong>ch<br />
With display / Spanish<br />
With display / Italian<br />
With display / Japanese<br />
Clear-text language.<br />
Operating m<strong>en</strong>u<br />
available only with<br />
display.<br />
Cable input M16 (relay: M20)<br />
Cable input NPT ½”<br />
Cable contact via via M plug connection<br />
for signal and supply (for optional relays: M20 cable<br />
input)<br />
without E<strong>the</strong>rnet module<br />
with E<strong>the</strong>rnet module<br />
* Standard scaling is delivered if “min” and “max” are not specified.<br />
** not with code “B01”<br />
Relay parameterization wh<strong>en</strong> commissioning via operating m<strong>en</strong>u<br />
(display) or P2A software<br />
G01<br />
G02<br />
G03<br />
G04<br />
G05<br />
H00<br />
H01<br />
H02<br />
K01<br />
K02<br />
K03<br />
K04<br />
K05<br />
K06<br />
K07<br />
%RH / min / max<br />
°C / min / max<br />
°F / min / max<br />
°C td<br />
/ min / max<br />
°F td<br />
/ min / max<br />
Without relay<br />
4 relay outputs, limit value moni<strong>to</strong>ring<br />
4 relay outputs, limit values channel 1 + collective alarm<br />
IM German-English<br />
IM Fr<strong>en</strong>ch-English<br />
IM Spanish-English<br />
IM Italian-English<br />
IM Dutch-English<br />
IM Japanese-English<br />
IM Chinese-English<br />
Order example for tes<strong>to</strong> 6651 transmitter<br />
Housing with display with m<strong>en</strong>u in English<br />
4 <strong>to</strong> 20 mA (2-wire)<br />
Cable input M16/M20<br />
with E<strong>the</strong>rnet module<br />
Fac<strong>to</strong>ry setting channel 1:<br />
%RH with scaling min 0 %, max 100 %*<br />
Fac<strong>to</strong>ry setting channel 2:<br />
°C with scaling min -10 °C/-14 °F,<br />
max +70 °C/+158 °F*<br />
without relay<br />
Instruction manual in German and English<br />
Channel 2*<br />
0555 6651 A01 / B01 / C03 / D01 / E01 / F01 /<br />
G02 / -10 / +70 / H00 / K01<br />
**<br />
0555 6600 Lxx Mxx<br />
Nxx<br />
Pxx<br />
L01<br />
L02<br />
L03<br />
L04<br />
L05<br />
M01<br />
M02<br />
M03<br />
M04<br />
M05<br />
Probe 6601 (wall version)<br />
Probe 6602 (duct version -20 <strong>to</strong> 70 °C)<br />
Probe 6603 (duct version -30 <strong>to</strong> 120 °C)<br />
Probe 6604 (cable version -20 <strong>to</strong> 70 °C)<br />
Probe 6605 (cable version -30 <strong>to</strong> 120 °C)<br />
Sintered stainless steel filter<br />
Wire mesh protective cap<br />
Sintered Teflon filter<br />
Metal protective cap, op<strong>en</strong><br />
Plastic cap ABS, op<strong>en</strong><br />
N00<br />
N01<br />
N02<br />
N05<br />
N23<br />
P07<br />
P14<br />
P20<br />
P28<br />
P50<br />
Without cable (for probe 6601)<br />
Cable l<strong>en</strong>gth 1 m (for probes 6604/6605)<br />
Cable l<strong>en</strong>gth 2 m (for probes 6604/6605)<br />
Cable l<strong>en</strong>gth 5 m (for probe 6605 only)<br />
Cable l<strong>en</strong>gth, specially for duct versions<br />
(for probes 6602/6603)<br />
Probe l<strong>en</strong>gth 70 mm<br />
Probe l<strong>en</strong>gth 140 mm<br />
Probe l<strong>en</strong>gth 200 mm<br />
Probe l<strong>en</strong>gth 280 mm<br />
Probe l<strong>en</strong>gth 500 mm<br />
L01 L02 L03 L04 L05<br />
X – – – –<br />
– – – X –<br />
X – – – X<br />
– X X X –<br />
– – – – X<br />
Ordering procedure:<br />
Transmitters and probes can be ordered indep<strong>en</strong>d<strong>en</strong>tly of<br />
each o<strong>the</strong>r, (on account of <strong>the</strong> digital probe interface), cf.<br />
order examples above.<br />
If <strong>the</strong> transmitter and probe order are <strong>to</strong> be assembled<br />
<strong>to</strong>ge<strong>the</strong>r, <strong>the</strong>ir order codes are combined in <strong>the</strong> distribution<br />
set 0563 6651<br />
Order example for 6602 probe<br />
Duct probe ( (-20 <strong>to</strong> +70 °C/-4 <strong>to</strong> 158 °F are suffici<strong>en</strong>t)<br />
Sintered stainless steel filter<br />
Probe l<strong>en</strong>gth 280 mm<br />
<br />
0555 6600 L02 / M01 / N23 / P28<br />
7
Technical data for tes<strong>to</strong> 6651 transmitter and tes<strong>to</strong> 6600 probes<br />
GENERAL<br />
Housing<br />
Dim<strong>en</strong>sions<br />
Weight<br />
Display<br />
Resolution display<br />
ANALOG OUTPUT (uniform for all channels, specify wh<strong>en</strong> ordering)<br />
ADDITIONAL OUTPUTS<br />
Plastic<br />
122 x 162 x 77 mm (without probe)<br />
0.62 kg (without probe)<br />
2-line LCD with clear-text line (optional) and relay status display. Four operating but<strong>to</strong>ns for operating m<strong>en</strong>u.<br />
0.1 %RH and 0.1 °C / °F / °C td<br />
/ °F td<br />
/ °C tw<br />
/ °F tw<br />
and 1g / kg / g/m 3 /<br />
ppm<br />
Cable screw fitting M 16 x 1.5 (2x) with inner diameter 4-8 mm for signal/supply cable (for option D01)<br />
M 20 x 1.5 (2x) with inner diameter 6-12 mm for relay cable (for options D01 or D03)<br />
Power supply<br />
4-wire: 20 <strong>to</strong> 30 VAC/DC, 300 mA max. curr<strong>en</strong>t consumption<br />
Protection class IP 65<br />
EMC<br />
2004/108/EU<br />
Operating temperature housing -40 <strong>to</strong> +70 °C/-40 <strong>to</strong> +158°F, with display 0 <strong>to</strong> +50 °C/32 <strong>to</strong> +122 °F, optimum at +15 <strong>to</strong> 35 °C/+59 <strong>to</strong> 95 °F<br />
S<strong>to</strong>rage temperature -40 <strong>to</strong> +80 °C/-40 <strong>to</strong> +176 °F<br />
Measurem<strong>en</strong>t parameters<br />
Temperature in °C / °F; Relative humidity %rF / %RH / %HR; Dewpoint in °C td<br />
/ °F td<br />
Quantity<br />
2 channels (type: analog signal uniform for both channels, specify wh<strong>en</strong> ordering)<br />
Curr<strong>en</strong>t/accuracy<br />
0 <strong>to</strong> 20 mA ±0.03 mA (4-wire) / 4 <strong>to</strong> 20 mA ±0.03 mA (4-wire) for heated s<strong>en</strong>sor technology<br />
Voltage/accuracy<br />
0 <strong>to</strong> 1 V ±1.5 mV (4-wire) / 0 <strong>to</strong> 5 V ±7.5 mV (4-wire) / 0 <strong>to</strong> 10 V ±15 mV (4-wire)<br />
Galvanic isolation<br />
Galvanic isolation of output channels (2-wire and 4-wire), isolation of supply <strong>to</strong> outputs (4-wire)<br />
Resolution<br />
12 bit<br />
Maximum load 4-wire 500 Ohm<br />
Relays (optional)<br />
4 relays (free allocation <strong>to</strong> measurem<strong>en</strong>t channels or as collective alarm with operating m<strong>en</strong>u/P2A software), up <strong>to</strong><br />
250 VAC / 3 A, (NC/C/NO)<br />
Digital output Mini DIN for Tes<strong>to</strong> P2A parameterization software and Tes<strong>to</strong> portable instrum<strong>en</strong>ts 400/650<br />
Model tes<strong>to</strong> 6601 tes<strong>to</strong> 6602 tes<strong>to</strong> 6603 tes<strong>to</strong> 6604 tes<strong>to</strong> 6605<br />
Type<br />
Application<br />
Measurem<strong>en</strong>t parameters<br />
Measuring range<br />
Material<br />
Measurem<strong>en</strong>t<br />
inaccuracy*<br />
Reproduceablility<br />
Probes<br />
Pressure tightness<br />
Humidity<br />
Temperature<br />
Probe shaft<br />
Cable<br />
Plug<br />
Humidity: (+25 °C)**<br />
Humidity: for deviations from <strong>the</strong><br />
media temperature ±25 °C<br />
Temperature: at +25 °C / +77 °F<br />
Humidity<br />
Diameter<br />
Wall<br />
Room climate probe<br />
wall mounting<br />
Duct<br />
-20 <strong>to</strong> +70 °C/-4 <strong>to</strong> +158 °F<br />
without<br />
Climate probe duct<br />
mounting<br />
Duct<br />
Process climate<br />
probe duct mounting<br />
for higher process<br />
temperatures<br />
%rF/%RH, °C td<br />
/°F td<br />
, °C/°F<br />
0 <strong>to</strong> 100 %RH<br />
Cable<br />
-30 <strong>to</strong> +120 °C/-22 <strong>to</strong> +248 °F -20 <strong>to</strong> +70 °C/-4 <strong>to</strong> +158 °F -30 <strong>to</strong> +120 °C/-22 <strong>to</strong> +248 °F<br />
Plastic ABS<br />
FEP coated<br />
Plastic ABS<br />
±1.7 %RH (0 <strong>to</strong> 90%) / ±1.9 %RH (90 <strong>to</strong> 100%)<br />
+0.02 %RH/K<br />
±0.2 °C / 0.38 °F (PT1000 Class A)<br />
better than ±0.5 %RH<br />
12 mm<br />
PN 1 (probe tip)<br />
Climate probe with<br />
cable<br />
Cable<br />
Stainless steel process<br />
probe with cable for<br />
higher process<br />
temperatures<br />
Stainless steel<br />
Pt1000 1/3 Class B<br />
PN 10 (probe tip)<br />
PN 3 (probe <strong>en</strong>d)<br />
* O<strong>the</strong>r accuracies apply for wall probes, 70 mm long, in combination with a curr<strong>en</strong>t output: humidity ±2.5 %RH; temperature ±1 °C<br />
** Determination of measurem<strong>en</strong>t uncertainty <strong>to</strong> GUM results in an additional uncertainty share of ±0.007 x MW (in %RH)<br />
8
Ordering data for tes<strong>to</strong> 6681 humidity transmitter<br />
0555 6681 A01 Bxx<br />
Cxx Dxx Exx Fxx Gxx Hxx Ixx Jxx Kxx<br />
B02<br />
B03<br />
B04<br />
B05<br />
B06<br />
C00<br />
C02<br />
C03<br />
C04<br />
C05<br />
C06<br />
C07<br />
D01<br />
D02<br />
D03<br />
E00<br />
E01<br />
F01<br />
F02<br />
F03<br />
F04<br />
F05<br />
F06<br />
F07<br />
F08<br />
F09<br />
F10<br />
F11<br />
F12<br />
F13<br />
F14<br />
F15<br />
G01<br />
G02<br />
G03<br />
G04<br />
G05<br />
G06<br />
G07<br />
G08<br />
G09<br />
G10<br />
G11<br />
G12<br />
G13<br />
G14<br />
G15<br />
0 <strong>to</strong> 1 V (4-wire, 24 VAC/DC)<br />
0 <strong>to</strong> 5 V (4-wire, 24 VAC/DC)<br />
0 <strong>to</strong> 10 V (4-wire, 24 VAC/DC)<br />
0 <strong>to</strong> 20 mA (4-wire, 24 VAC/DC)<br />
4 <strong>to</strong> 20 mA (4-wire, 24 VAC/DC)<br />
Without display<br />
With display / English<br />
With display / German<br />
With display / Fr<strong>en</strong>ch<br />
With display / Spanish<br />
With display / Italian<br />
With display / Japanese<br />
Cable input M16 (relay: M20)<br />
Cable input NPT ½”<br />
Cable contact via via M plug connection<br />
for signal and supply (for optional relays: M20<br />
cable input)<br />
without E<strong>the</strong>rnet module<br />
with E<strong>the</strong>rnet module<br />
%RH / min / max<br />
°C / min / max<br />
°F / min / max<br />
°C td<br />
/ min / max<br />
°F td<br />
/ min / max<br />
g/kg / min / max<br />
gr/lb / min / max<br />
g/m 3 / min / max<br />
gr/ft 3 / min / max<br />
ppmV / min / max<br />
°Cwb / min / max (Wet Bulb)<br />
°Fwb / min / max (Wet Bulb)<br />
kJ/kg / min / max (<strong>en</strong>thalpy)<br />
hPa / max (water vapour partial pressure)<br />
inch H 2<br />
O / min / max (water vapour partial<br />
pressure)<br />
%RH / min / max<br />
°C / min / max<br />
°F / min / max<br />
°C td<br />
/ min / max<br />
°F td<br />
/ min / max<br />
g/kg / min / max<br />
gr/lb / min / max<br />
g/m 3 / min / max<br />
gr/ft 3 / min / max<br />
ppmV / min / max<br />
°Cwb / min / max (Wet Bulb)<br />
°Fwb / min / max (Wet Bulb)<br />
kJ/kg / min / max (<strong>en</strong>thalpy)<br />
hPa / max (water vapour partial pressure)<br />
inch H 2<br />
O / min / max (water vapour partial<br />
pressure)<br />
Clear-text language.<br />
Operating m<strong>en</strong>u<br />
available only with<br />
display.<br />
Channel 1*<br />
Channel 2*<br />
H00<br />
H01<br />
H02<br />
I00<br />
I01<br />
I02<br />
I03<br />
I04<br />
I05<br />
I06<br />
I07<br />
I08<br />
I09<br />
I10<br />
I11<br />
I12<br />
I13<br />
I14<br />
I15<br />
I16<br />
I17<br />
K01<br />
K02<br />
K03<br />
K04<br />
K05<br />
K06<br />
K07<br />
Without relay<br />
4 relay outputs, limit value moni<strong>to</strong>ring<br />
4 relay outputs, limit values channel 1 + collective<br />
alarm<br />
no optional 3rd analog output<br />
%RH / min / max<br />
°C / min / max<br />
°F / min / max<br />
°C td<br />
/ min / max<br />
°F td<br />
/ min / max<br />
g/kg / min / max<br />
gr/lb / min / max<br />
g/m 3 / min / max<br />
gr/ft 3 / min / max<br />
ppmV / min / max<br />
°Cwb / min / max (Wet Bulb)<br />
°Fwb / min / max (Wet Bulb)<br />
kJ/kg / min / max (<strong>en</strong>thalpy)<br />
hPa / min / max (water vapour partial pressure)<br />
inch H 2<br />
O / min / max (water vapour partial pressure)<br />
°Ctm / mixture dewpoint for H 2<br />
O 2<br />
°Ftm / mixture dewpoint for H 2<br />
O 2<br />
IM German-English<br />
IM Fr<strong>en</strong>ch-English<br />
IM Spanish-English<br />
IM Italian-English<br />
IM Dutch-English<br />
IM Japanese-English<br />
IM Chinese-English<br />
Order example for tes<strong>to</strong> 6681 transmitter<br />
Housing with display with m<strong>en</strong>u in English<br />
4 <strong>to</strong> 20 mA (4-wire)<br />
Cable input M16/M20<br />
E<strong>the</strong>rnet module<br />
Fac<strong>to</strong>ry setting channel 1:<br />
°C tpd<br />
with scaling min 0 °C td<br />
, max 100 °C td<br />
*<br />
Fac<strong>to</strong>ry setting channel 2:<br />
°C with scaling min -10 °C/-14 °F,<br />
max +70 °C/+158 °F*<br />
with relay<br />
without 3rd channel<br />
Instruction manual in Spanish + English<br />
0555 6681 A01 / B06 / C02 / D01 / E01 / F04 / 0 /<br />
100 / G02 / -10 / +70 / H01 / I00 / K03<br />
* Standard scaling is delivered if “min” and “max” are not specified.<br />
not<br />
with<br />
B01<br />
Channel 3*<br />
9
Ordering data Probes tes<strong>to</strong> 6610<br />
0555 6610 Lxx Mxx<br />
Nxx<br />
Pxx<br />
L11<br />
L12<br />
L13<br />
L14<br />
L15<br />
L17<br />
Probe 6611 (wall version)<br />
Probe 6612 (duct version <strong>to</strong> 150 °C)<br />
Probe 6613 (cable version <strong>to</strong> 180 °C)<br />
Probe 6614 (heated cable version)<br />
Probe 6615 (trace humidity cable version)<br />
Probe 6617 (self-moni<strong>to</strong>red cable version)<br />
Order example for tes<strong>to</strong> 6613 probe<br />
Cable probe, -40 <strong>to</strong> +180 °C<br />
Sintered stainless steel filter<br />
Cable l<strong>en</strong>gth 2 m<br />
Probe l<strong>en</strong>gth 300 mm<br />
M01<br />
M02<br />
M03<br />
M04<br />
M06<br />
M07<br />
M08<br />
Sintered stainless steel filter<br />
Wire mesh protective cap<br />
Sintered Teflon filter<br />
Metal protective cap, op<strong>en</strong><br />
Teflon filter with drip hole<br />
Teflon filter w. drip hole a. cond<strong>en</strong>sation protection<br />
Filter for H 2<br />
O 2<br />
<strong>en</strong>vironm<strong>en</strong>ts**<br />
0555 6610 L13 / M01 / N02 / P30<br />
specially for high humidity<br />
N00<br />
N01<br />
N02<br />
N05<br />
N10<br />
N23<br />
Without cable<br />
Cable l<strong>en</strong>gth 1 m<br />
Cable l<strong>en</strong>gth 2 m<br />
Cable l<strong>en</strong>gth 5 m<br />
Cable l<strong>en</strong>gth 10 m<br />
Cable l<strong>en</strong>gth, specially for duct versions<br />
L11 L12 L13 L14 L15 L17<br />
X – – – – –<br />
– – X X X X<br />
– – X X X X<br />
– – X X X X<br />
– – X X X X<br />
– X – – – –<br />
P07<br />
P14<br />
P20<br />
P30<br />
P50<br />
P80<br />
Probe l<strong>en</strong>gth 70 mm<br />
Probe l<strong>en</strong>gth 120 mm<br />
Probe l<strong>en</strong>gth 200 mm<br />
Probe l<strong>en</strong>gth 300 mm<br />
Probe l<strong>en</strong>gth 500 mm<br />
Probe l<strong>en</strong>gth 800 mm<br />
L11 L12 L13 L14 L15 L17<br />
X – – – –<br />
– – X – – –<br />
X X X X X X<br />
– X X – – –<br />
– X X X X X<br />
– X X – – –<br />
Ordering procedure:<br />
Transmitters and probes can be ordered indep<strong>en</strong>d<strong>en</strong>tly of each o<strong>the</strong>r, (on account of <strong>the</strong> digital probe interface), cf. order examples above.<br />
If <strong>the</strong> transmitter and probe order are <strong>to</strong> be assembled <strong>to</strong>ge<strong>the</strong>r, <strong>the</strong>ir order codes are combined in <strong>the</strong> distribution set 0563 6651<br />
**H2O2 processes:<br />
With tes<strong>to</strong> 6681, Tes<strong>to</strong> offers a transmitter which can also be used in hydrog<strong>en</strong> peroxide processes (H2O2) – for example in sterilization. The<br />
s<strong>en</strong>sor is protected with <strong>the</strong> help of a special probe (Code M08). The so-called “mixture dewpoint” °Ctm/°Ftm is also displayed.<br />
10
Technical data for <strong>the</strong> tes<strong>to</strong> 6681 transmitter and tes<strong>to</strong> 6610 probes<br />
GENERAL<br />
Housing<br />
Dim<strong>en</strong>sions<br />
Weight<br />
Display<br />
Resolution display<br />
Metal<br />
122 x 162 x 77 mm (without probe)<br />
1.5 kg (without probe, without E<strong>the</strong>rnet module)<br />
ANALOG OUTPUT (uniform for all channels, specify wh<strong>en</strong> ordering)<br />
2-line LCD with clear-text line (optional) and relay status display. Four operating but<strong>to</strong>ns for operating m<strong>en</strong>u.<br />
0.1 %RH and 0.1 °C / °F / °C td / °F td / °C tw / °F tw and 1g / kg / g/m 3 / ppm<br />
Cable screw fitting M 16 x 1.5 (2x) with inner diameter 4-8 mm for signal/supply cable (for option D01)<br />
M 20 x 1.5 (2x) with inner diameter 6-12 mm for relay cable (for options D01 or D03)<br />
Power supply<br />
Protection class IP 65<br />
EMC<br />
4-wire: 20 <strong>to</strong> 30 VAC/DC, 300 mA max. curr<strong>en</strong>t consumption<br />
2004/108/EU<br />
Operating temperature housing -40 <strong>to</strong> +70 °C/-40 <strong>to</strong> +158°F, with display 0 <strong>to</strong> +50 °C/32 <strong>to</strong> +122 °F, optimum at +15 <strong>to</strong> 35 °C/+59 <strong>to</strong> 95 °F<br />
S<strong>to</strong>rage temperature -40 <strong>to</strong> +80 °C/-40 <strong>to</strong> +176 °F<br />
Measurem<strong>en</strong>t parameters<br />
Quantity<br />
Curr<strong>en</strong>t/accuracy<br />
Voltage/accuracy<br />
Galvanic isolation<br />
Resolution<br />
Maximum load<br />
Dep<strong>en</strong>ding on probe, <strong>the</strong> following is available:<br />
Temperature in °C / °F; relative humidity %rF (%RH); dewpoint in °C td (°F td ); pressure dewpoint in °C tpd (°F tpd ); absolute humidity<br />
in g/m 3 (gr/ft 3 ); degree of humidity in g/kg (gr/lb); <strong>en</strong>thalpy in kJ/kg (BTU/lb); psychrometer temperature in °Ctw (°Ftw); water<br />
vapour partial pressure in hPa / H 2 O; water cont<strong>en</strong>t in ppm vol / % Vol; mixture dewpoint H 2 O 2 / in °Ctm / °Ftm<br />
2 channels (type: analog signal uniform for both channels, specify wh<strong>en</strong> ordering)<br />
additional 3rd channel (optional)<br />
0 <strong>to</strong> 20 mA ±0.03 mA (4-wire) / 4 <strong>to</strong> 20 mA ±0.03 mA (4-wire)<br />
0 <strong>to</strong> 1 V ±1.5 mV (4-wire) / 0 <strong>to</strong> 5 V ±7.5 mV (4-wire) / 0 <strong>to</strong> 10 V ±15 mV (4-wire)<br />
Galvanic isolation of output channels (2-wire and 4-wire), isolation of supply <strong>to</strong> outputs (4-wire)<br />
12 bit<br />
4-wire 500 Ohm<br />
ADDITIONAL OUTPUTS<br />
Relays (optional) 4 relays (free allocation <strong>to</strong> measurem<strong>en</strong>t channels or as collective alarm with operating m<strong>en</strong>u/P2A software), up <strong>to</strong> 250 VAC /<br />
3 A, (NC/C/NO)<br />
Digital output Mini DIN for Tes<strong>to</strong> P2A parameterization software and Tes<strong>to</strong> portable instrum<strong>en</strong>ts 400/650<br />
Pro bus-DP (optional as an integratable intermediate layer, cannot be combined with E<strong>the</strong>rnet module)<br />
Model tes<strong>to</strong> 6611 tes<strong>to</strong> 6612 tes<strong>to</strong> 6613 tes<strong>to</strong> 6614 tes<strong>to</strong> 6615 tes<strong>to</strong> 6617<br />
Type<br />
Wall<br />
Duct<br />
Cable<br />
Heated cable<br />
Cable trace humidity<br />
(self-adjustm<strong>en</strong>t)<br />
Cable with cover<br />
electrode moni<strong>to</strong>ring<br />
Application<br />
Measurem<strong>en</strong>t parameters<br />
Measuring range<br />
Material<br />
Measurem<strong>en</strong>t<br />
inaccuracy*<br />
Reproduceablility<br />
Probes<br />
Pressure tightness<br />
Humidity<br />
Temperature<br />
Probe shaft<br />
Cable<br />
Plug<br />
Humidity: (+25 °C)**<br />
Humidity: for deviations from <strong>the</strong><br />
media temperature ±25 °C<br />
Pressure dewpopint<br />
Temperature: at +25 °C / +77 °F<br />
Humidity<br />
Diameter<br />
Room climate<br />
probe wall<br />
mounting<br />
°C/°F, %rF/%RH, °C td /°F td , °C tpd /°F tpd , g/m 3 /gr/ft 3 , g/kg/gr/lb, kJ/kg, BTU/lb, °Ctw/°Ftw, hPa, inch H 2 O, ppm vol %, %vol, °Ctm<br />
(H 2 O 2 )/°Ftm (H 2 O 2 )<br />
0 <strong>to</strong> 100 %RH<br />
-60 <strong>to</strong> +30 °C tpd 0 <strong>to</strong> 100 %RH<br />
-20 <strong>to</strong> +70 °C/-4 <strong>to</strong><br />
+158 °F<br />
Process humidity<br />
probe duct<br />
mounting<br />
-30 <strong>to</strong> +150 °C/-22 <strong>to</strong><br />
+302 °F<br />
Process humidity<br />
probe flexible<br />
with cable<br />
±0.2 °C / 0.38 °F (Pt1000 1/3 Class B)<br />
-40 <strong>to</strong> +180 °C/-40 <strong>to</strong> +356 °F -40 <strong>to</strong> +120 °C/-22 <strong>to</strong><br />
+302 °F<br />
Stainless steel<br />
FEP coated<br />
Plastic ABS<br />
+0.02 %RH/K<br />
better than ±0.5 %RH<br />
PN 10 (probe tip)<br />
PN 3 (probe <strong>en</strong>d)<br />
Humidity probe for<br />
high humidity<br />
applications / wh<strong>en</strong><br />
risk of cond<strong>en</strong>sation<br />
Humiditiy probe for<br />
trace humidity /<br />
pressure dewpoint<br />
(with selfadjustm<strong>en</strong>t)<br />
±1.0 %RH (0 <strong>to</strong> 90%) (tes<strong>to</strong> 6614 only: 0 <strong>to</strong> 100%)/ ±1.4 %RH (90 <strong>to</strong> 100%) for tes<strong>to</strong> 6611/12/13<br />
±1.2 %RH (0 <strong>to</strong> 90%)/ ±1.6 %RH (90 <strong>to</strong> 100%) for tes<strong>to</strong> 6617<br />
1 bar positive pressure (probe tip)<br />
12 mm<br />
* O<strong>the</strong>r accuracies apply for wall probes, 70 mm long, in combination with a curr<strong>en</strong>t output: humidity ±2.5 %RH; temperature ±1 °C<br />
** Determination of measurem<strong>en</strong>t uncertainty <strong>to</strong> GUM results in an additional uncertainty share of ±0.007 x MW (in %RH)<br />
±1 K at 0° C tpd<br />
±2 K at -40° C tpd<br />
±4 K at -50° C tpd<br />
(Pt1000 1/3 Class B)<br />
PN 16 (probe tip)<br />
Humidity probe with<br />
self-moni<strong>to</strong>ring for<br />
s<strong>en</strong>sor-damaging<br />
media<br />
-40 <strong>to</strong> +180 °C/-40 <strong>to</strong><br />
+356 °F<br />
1 bar positive<br />
pressure (probe tip)<br />
11