25.03.2014 Views

Committing to the future - RCC Koude en Luchtbehandeling

Committing to the future - RCC Koude en Luchtbehandeling

Committing to the future - RCC Koude en Luchtbehandeling

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1. Measurem<strong>en</strong>t data moni<strong>to</strong>ring using tes<strong>to</strong> Saveris TM and humidity transmitter<br />

The E<strong>the</strong>rnet module with tes<strong>to</strong> 6651and<br />

tes<strong>to</strong> 6681 transmitters can be operated in<br />

two modes:<br />

1. Integration of transmitter in <strong>the</strong> tes<strong>to</strong><br />

Saveris measurem<strong>en</strong>t data moni<strong>to</strong>ring<br />

system<br />

2. Integration of transmitter in cus<strong>to</strong>mer’s<br />

moni<strong>to</strong>ring system (op<strong>en</strong> log)<br />

1. tes<strong>to</strong> Saveris now fit for all humidity<br />

applications<br />

If <strong>the</strong> E<strong>the</strong>rnet module is operated in <strong>the</strong> tes<strong>to</strong><br />

Saveris mode, tes<strong>to</strong> 6651 and tes<strong>to</strong> 6681<br />

transmitters can be easily implem<strong>en</strong>ted in <strong>the</strong><br />

tes<strong>to</strong> Saveris measurem<strong>en</strong>t data moni<strong>to</strong>ring<br />

system. In addition <strong>to</strong> actual measurem<strong>en</strong>t<br />

data docum<strong>en</strong>tation and visualisation using<br />

tes<strong>to</strong> Saveris software, <strong>the</strong>re is also <strong>the</strong><br />

option of notifying <strong>the</strong> person responsible for<br />

<strong>the</strong> system if limits are exceeded.<br />

In this operating mode, <strong>the</strong> transmitter has an<br />

internal data s<strong>to</strong>re which prev<strong>en</strong>ts data from<br />

getting lost if <strong>the</strong> LAN connection breaks<br />

down. All of <strong>the</strong> humidity parameters (e.g.<br />

%RH, g/m³, g/kg, ppm, etc.) can be<br />

transmitted. The transmitter is parameterised<br />

using P2A software or <strong>the</strong> transmitter’s<br />

operating m<strong>en</strong>u.<br />

While moni<strong>to</strong>ring using tes<strong>to</strong> Saveris, PLC<br />

control (if required) is possible with <strong>the</strong><br />

transmitters.<br />

In addition <strong>to</strong> <strong>the</strong> tes<strong>to</strong> 6681 transmitter<br />

humidity probes, <strong>the</strong>re are now also probes<br />

available for special applications such as high<br />

humidity, trace humidity, corrosive<br />

substances or H 2<br />

O 2<br />

atmospheres. The probe<br />

options also facilitate direct installation on<br />

ducts as well as <strong>the</strong> moni<strong>to</strong>ring of processes<br />

<strong>to</strong> 180 °C using cable probes.<br />

Transmitter<br />

Memory for s<strong>to</strong>ring<br />

data,<br />

24 VDC/AC power<br />

PLC<br />

Control/Regulation<br />

In addition <strong>to</strong> operating<br />

in <strong>the</strong> Saveris system,<br />

analog outputs can be<br />

used simultaneously for<br />

control<br />

tes<strong>to</strong> 6681/tes<strong>to</strong> 6651 +<br />

E<strong>the</strong>rnet module<br />

Analog signals,<br />

e.g. 4 <strong>to</strong> 20 mA<br />

E<strong>the</strong>rnet<br />

Up <strong>to</strong> 127<br />

transmitters can be<br />

integrated in a<br />

Saveris system (2<br />

channels per<br />

transmitter)<br />

tes<strong>to</strong> 6681/tes<strong>to</strong> 6651:<br />

Measurem<strong>en</strong>t data is logged and transmitted <strong>to</strong> tes<strong>to</strong> Saveris/PLC<br />

4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!