Product overview<br />
<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, <strong>CR</strong>E, <strong>CR</strong>IE, <strong>CR</strong>NE<br />
Terminal box positions<br />
As standard the terminal box is mounted on the suction<br />
side of the pump.<br />
Stellung 6 Position 6 Position Stellung 9 9 Position Stellung 12 12 Stellung 3 Position 3<br />
Standard<br />
TM02 18 05 2001<br />
Fig. 4 Terminal box positions<br />
Ambient temperature<br />
Ambient temperature: Maximum +104 °F.<br />
If the ambient temperature exceeds +104 °F or if the<br />
motor is located 3280 feet above sea level or higher,<br />
the motor output (P2) must be reduced due to the low<br />
cooling effect of the air. In such cases, it may be<br />
necessary to use a motor with a higher output.<br />
2<br />
100<br />
90<br />
70<br />
1 = Baldor motors<br />
2 = <strong>Grundfos</strong> ML motors<br />
1<br />
80<br />
60<br />
50<br />
TM03 4272<br />
3280 7382 11483 15584 ft<br />
Fig. 5 Relationship between motor output (P2) and<br />
ambient temperature<br />
Viscosity<br />
The pumping of liquids with densities or kinematic<br />
viscosities higher than those of water will cause a<br />
considerable pressure drop, a drop in the hydraulic<br />
performance and a rise in the power consumption.<br />
In such situations the pump should be equipped with a<br />
larger motor. If in doubt, contact <strong>Grundfos</strong>.<br />
10