Operating and inlet<br />

pressure<br />

<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, <strong>CR</strong>E, <strong>CR</strong>IE, <strong>CR</strong>NE<br />

Operating range of the shaft seal<br />

The operating range of the shaft seal depends on<br />

operating pressure, pump type, type of shaft seal and<br />

liquid temperature. The following curves apply to clean<br />

water and water with anti-freeze liquids. For selecting<br />

the right shaft seal, see List of pumped liquids on<br />

page 74.<br />

<strong>CR</strong> 1s - <strong>CR</strong> 20<br />

p<br />

[bar]<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

p<br />

[psi]<br />

400<br />

300<br />

200<br />

100<br />

HQQE<br />

0<br />

-40 0 40 80 120 160 200 240 t [°F]<br />

Fig. 14 Operating range of standard shaft seals for<br />

<strong>CR</strong> 1s - <strong>CR</strong> 20<br />

<strong>CR</strong> 32 - <strong>CR</strong> 150 (3.0-60 Hp)<br />

p<br />

[bar]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

HQQE<br />

HQQV<br />

HQQE<br />

p<br />

[psi]<br />

500<br />

HUBE / HUBV HUBE<br />

400<br />

300<br />

KUHE / KUHV<br />

200<br />

KUBE / KUBV KUBE<br />

KUUE / KUUV<br />

100<br />

0<br />

-40 0 40 80 120 160 200 240 t [°F]<br />

KUUE<br />

KUUE<br />

KUUV<br />

-40 -20 0 20 40 60 80 100 t [°C]<br />

TM02 7537 3703<br />

TM02 7873 0604<br />

Shaft<br />

seal<br />

Description<br />

HQQE<br />

O-ring (cartridge) (balanced seal),<br />

SiC/SiC, EPDM<br />

HBQE<br />

O-ring (cartridge) (balanced seal),<br />

Carbon/SiC, EPDM<br />

HQQV<br />

O-ring (cartridge) (balanced seal),<br />

SiC/SiC, FKM<br />

HUBE<br />

O-ring (cartridge) (balanced seal),<br />

TC/carbon, EPDM<br />

HUBV<br />

O-ring (cartridge) (balanced seal),<br />

TC/carbon, FKM<br />

KUBE<br />

Bellows, metal (cartridge),<br />

TC/carbon, EPDM<br />

KUBV<br />

Bellows, metal (cartridge),<br />

TC/carbon, FKM<br />

Bellows, metal (cartridge),<br />

KUHE TC/Carbon with embedded TC,<br />

EPDM<br />

Bellows, metal (cartridge),<br />

KUHV TC/Carbon with embedded TC,<br />

FKM<br />

KUUE<br />

Bellows, metal (cartridge), TC/TC,<br />

EPDM<br />

KUUV<br />

Bellows, metal (cartridge), TC/TC,<br />

FKM<br />

Note: TC= tungsten carbide<br />

See section Lists of variants - on request on page 83,<br />

in case of extreme temperatures:<br />

• low temperatures down to –40 °F or<br />

• high temperatures up to +356 °F.<br />

Max. temp.<br />

range [ °F]<br />

–22 °F to +248 °F<br />

+32 °F to +248 °F<br />

–4 °F to +194 °F<br />

+32 °F to +248 °F<br />

+32 °F to +194 °F<br />

+32 °F to +248 °F<br />

+32 °F to +194 °F<br />

+32 °F to +194 °F<br />

+32 °F to +194 °F<br />

–22 °F to +194 °F<br />

–4 °F to +194 °F<br />

Fig. 15 Operating range of standard shaft seals for<br />

<strong>CR</strong> 32 - <strong>CR</strong> 150 (3.0-60 Hp)<br />

<strong>CR</strong> 120 - <strong>CR</strong> 150 (75-100 Hp)<br />

p<br />

[psi]<br />

400<br />

300<br />

200<br />

100<br />

HQQE<br />

HQQV<br />

HQQE<br />

HQQE/V<br />

HBQE/V<br />

HQQE<br />

HBQE<br />

0<br />

-80 -40 0 40 80 120 160 200 240 t [°F]<br />

TM04 4415<br />

Fig. 16 Operating range of standard shaft seals for<br />

<strong>CR</strong> 120 - <strong>CR</strong> 150 (75-100 Hp)<br />

19