MT-4E Analog and P25 Digital Radio Systems - Daniels Electronics
MT-4E Analog and P25 Digital Radio Systems - Daniels Electronics
MT-4E Analog and P25 Digital Radio Systems - Daniels Electronics
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
52<br />
Chapter 5: <strong>Daniels</strong> <strong>Radio</strong> System Testing<br />
Ensure that the receiver <strong>and</strong> transmitter are connected to the repeater controller via the RJ45 cables<br />
on the front panel. In some systems, the receiver <strong>and</strong> transmitter may be connected directly together<br />
using the RJ45 cables.<br />
Figure 5-40: System <strong>Analog</strong> Duplex Measurement<br />
Demodulated Audio Frequency:<br />
Check the COUNT meter on the meter panel. The demodulated audio should read the same as the<br />
modulated input. The low <strong>and</strong> high alarms are set for 995 Hz <strong>and</strong> 1005 Hz.<br />
Distortion:<br />
The distortion meter will read demodulated audio <strong>and</strong> give you a complete repeater system distortion<br />
reading. The High Alarm is set to 4.0 %.<br />
Enter the System Distortion reading on the <strong>MT</strong>-<strong>4E</strong> Test Sheet.<br />
Maintenance<br />
Guide<br />
MG-001 <strong>Daniels</strong> <strong>MT</strong>-<strong>4E</strong> <strong>Radio</strong> <strong>Systems</strong><br />
www.danelec.com