6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF225-CWU<br />

<strong>Series</strong><br />

Group<br />

Frame size<br />

Type name<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

C series<br />

<strong>WS</strong>S G3<br />

225<br />

NF225-CWU<br />

125 150 175<br />

200 225<br />

Type NF225-CWU<br />

Number of poles 3<br />

Rated short-circuit braking<br />

capacities (kA)<br />

UL489<br />

IEC60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Standard attached parts<br />

Rated voltage (AC V)<br />

AC<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

500V<br />

440V<br />

400V<br />

230V<br />

250V<br />

240<br />

35<br />

600<br />

10/5<br />

15/8<br />

18/9<br />

35/18<br />

10/5 (*1)<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (4pcs),<br />

Terminal cover: (1 set), (*2)<br />

Insulation board: (1pc)<br />

Notes: (*1) Use either two poles. When wired as shown at the bottom of page 13, the models can<br />

be used for up to 400 V DC.<br />

(*2) The standard configuration contains a protection cover and adopts the IP20 (finger<br />

protection) structure.<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

NF225-CWU<br />

6min<br />

4min<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

Min.<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.35<br />

Time-delay trip<br />

Instantaneous trip<br />

2 3 4 5 6 7 10 15 20 30 40<br />

100 of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

<br />

<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

80<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

40<br />

50<br />

60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

<br />

<br />

<br />

<br />

Type name<br />

<br />

<br />

<br />

<br />

Accessories<br />

Mechanical interlock<br />

Terminal<br />

cover<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

<br />

Type name<br />

<br />

<br />

59