Product design which pursues greater use ease by wide variations<br />
Interchangeable Relay Unit<br />
To enhance flexibility, the Mitsubishi<br />
<strong>WS</strong> <strong>Series</strong> is equipped with<br />
interchangeable relay units (available<br />
in thermal or electronic types).<br />
The move has been made to<br />
AC/DC common use, while the<br />
expanded adjustment range enables<br />
reduction in the number of 250AF<br />
relays from 10 to 7 types.<br />
A magnetic adjustable function has<br />
been added to the thermal type,<br />
while 4P neutral protection has also<br />
been enhanced.<br />
(Note: Only authorized members<br />
available to replace)<br />
Thermal type unit<br />
4 10<br />
Electronic type unit<br />
Thermal Adjustable Relay<br />
6 8<br />
Ii(DC)=1.3XIi(AC) 4 10<br />
Ii(X250A AC)<br />
T<br />
Ir<br />
Ii<br />
MODEL<br />
RT<br />
250<br />
In 250 A<br />
50/60Hz<br />
40 3P3E<br />
160<br />
200<br />
Ir(A)<br />
250<br />
MADE IN JAPAN<br />
LN326N433-1<br />
Rating<br />
Type<br />
In (A)<br />
NF250-SGW / HGW<br />
NF160-SGW / HGW<br />
NF125-SGW / HGW<br />
Tripping threshold Ir (A)<br />
(note 1)<br />
Neutral protection<br />
4P 3E<br />
4P 4E<br />
25 40 63 100 125 160 250<br />
● ●<br />
●<br />
● ● ● ● ●<br />
Overload Protection (Thermal)<br />
Adjustable<br />
16-25 25-40 40-63 63-100 80-125 125-160<br />
No Protection<br />
1 × Ir<br />
160-250 (160-225)<br />
Tripping threshold Ii<br />
Short-Circuit Protection (Magnetic)<br />
Fixed<br />
10 × In<br />
Adjustable<br />
4 to 10 × In<br />
Note: (1) The type 4P 3E is standard. If the type 4P 4E is required, specify the type 4P 4E separately and explicitly.<br />
Ir Ii I<br />
Electronic Relay<br />
LN326N429-11<br />
MODEL<br />
T<br />
Ir<br />
MADE IN JAPAN<br />
Ip<br />
TL<br />
RE250 In<br />
250<br />
A<br />
Is<br />
AC only<br />
50/60Hz<br />
Ii 70% PAL<br />
Ts<br />
Ir (A) TEST T L(s) Is (XIr) Ts (s)<br />
Ip (XIr)<br />
200<br />
80<br />
4 5<br />
160<br />
60<br />
3.5<br />
6<br />
2 Ii (X250A) 8<br />
85<br />
1<br />
10<br />
8<br />
9<br />
3<br />
7<br />
6<br />
12<br />
95<br />
2.5<br />
8<br />
75<br />
125<br />
250 12 100 2 10 06<br />
3 4 14 7<br />
1.0<br />
OVER<br />
I pN<br />
4P3E 4P4E<br />
Rating In (A) (40°C)<br />
NF250-SGW / HGW<br />
Type NF160-SGW / HGW<br />
NF125-SGW / HGW<br />
LTD<br />
Tripping threshold Ir (A)<br />
Tripping time<br />
TL(s)<br />
Neutral protection (Slectable)<br />
32 63 100 125 160 250<br />
●<br />
●<br />
● ● ● ●<br />
Overload Protection<br />
Adjustable<br />
16-32 32-63 63-100 75-125 80-160 125-250<br />
12-60-80-100 step adjustable (at 2 × Ir)<br />
0-1 × Ir (Step adjustable)<br />
T<br />
Ip<br />
TL<br />
Ir<br />
Is<br />
Ts<br />
Ii<br />
I<br />
STD<br />
INST<br />
PAL<br />
Pickup current Is<br />
Tripping time Ts(s)<br />
Tripping threshold Ii<br />
Pickup current Ip<br />
Operating time Tp<br />
70%-LED (green)<br />
PAL-LED (orange)<br />
Over -LED (red)<br />
Short-Circuit Protection<br />
2-2.5-3-3.5-4-5-6-7-8-10 × Ir step adjustable<br />
0.06-0.1-0.2-0.3 step adjustable (at 1.5 × Is)<br />
4 to 14 × In continuous adjustable<br />
Pre-Alarm<br />
0.7-0.75-0.8-0.85-0.9-0.95-1.0 × Ir step adjustable<br />
TL/2<br />
Indicator (LED)<br />
Lit at 0.7 × Ir<br />
Flashing at lp and lit at Tp<br />
Lit at 1.15 × Ir<br />