25.04.2014 Views

WS Series - autocentrated

WS Series - autocentrated

WS Series - autocentrated

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7. Ordering Information<br />

Molded-Case Circuit Breakers<br />

Earth-Leakage Circuit Breakers<br />

Type name<br />

NF250-SW<br />

C<br />

S<br />

NF<br />

H<br />

U<br />

MB<br />

Economy type<br />

Standard type<br />

High-performance type<br />

Ultra current-limiting type<br />

Motor braker<br />

Type name<br />

NV250-SW<br />

NV<br />

C<br />

S<br />

H<br />

U<br />

Economy type<br />

Standard type<br />

High-performance type<br />

Ultra current-limiting type<br />

Number of poles<br />

Number of poles<br />

2P<br />

NV<br />

1ø2W<br />

3P<br />

NF<br />

MB<br />

2P, 3P<br />

3P<br />

3P<br />

3P<br />

NV<br />

1ø2W<br />

1ø3W<br />

3ø3W<br />

Rated current<br />

200A<br />

Even for adjustable rated current<br />

models, the working current should be<br />

specified.<br />

Rated current<br />

200A<br />

4P<br />

NV<br />

3ø4W<br />

Even for adjustable rated current<br />

models, the working current should be<br />

specified.<br />

Rated voltage<br />

Secify DC voltage when for use in<br />

DC circuit<br />

Rated voltage<br />

AC230-400-440V<br />

AC230-400-440V<br />

<br />

Specify the applicable marine<br />

standards<br />

∗ “CE” is standard.<br />

Rated sensitivity<br />

current<br />

100 • 300 • 500mA<br />

30 • 100 • 500mA<br />

100 • 300 • 500mA<br />

Connection<br />

method<br />

B<br />

F<br />

SL<br />

B<br />

PM<br />

Front connection<br />

Solderless (box) terminal<br />

Rear connection<br />

Pulg-in<br />

Connection<br />

method<br />

B<br />

F<br />

SL<br />

B<br />

PM<br />

Front connection<br />

Solderless (box) terminal<br />

Rear connection<br />

Pulg-in<br />

Internal<br />

accessories<br />

AL, SHT (AC110V)<br />

External<br />

accessories<br />

Quantity<br />

10<br />

AL<br />

AX<br />

SHT<br />

UVT<br />

PAL<br />

SLT<br />

INT<br />

MD<br />

F • S • V<br />

S • I • W<br />

MI<br />

TC<br />

LC • HL<br />

HL-S<br />

CH<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

(Specify rated coil voltage.)<br />

Under voltage trip<br />

(Specify rated coil voltage.)<br />

Pre-alarm module<br />

Lead-wire terminal block<br />

Internal terminal type<br />

Electrical operation device<br />

Operating handle<br />

Enclosure box<br />

Mechanical interlock<br />

Terminal cover<br />

(TC-L, TC-S, TTC, BTC)<br />

Handle lock device<br />

Card holder<br />

Type of residual<br />

carrent protection<br />

Internal<br />

accessories<br />

AX, SLT, TBM<br />

External<br />

accessories<br />

Quantity<br />

10<br />

Blank<br />

Specify<br />

AL<br />

AX<br />

UVT<br />

MG<br />

EAL<br />

TBM<br />

PAL<br />

SLT<br />

MD<br />

F • S • V<br />

S • I • W<br />

MI<br />

TC<br />

High-speed type<br />

Time-delay type<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

Insulation switch<br />

Earth-leakage circuit alarm switch<br />

Test button module<br />

Pre-alarm module<br />

Lead-wire terminal block<br />

Electrical operation device<br />

Operating handle<br />

Enclosure box<br />

Mechanical interlock<br />

Terminal cover<br />

(TC-L, TC-S, TTC, BTC)<br />

LC • HL<br />

HL-S<br />

Handle lock device<br />

CH<br />

Card holder<br />

62

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!