WS Series - autocentrated
WS Series - autocentrated
WS Series - autocentrated
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
7. Ordering Information<br />
Molded-Case Circuit Breakers<br />
Earth-Leakage Circuit Breakers<br />
Type name<br />
NF250-SW<br />
C<br />
S<br />
NF<br />
H<br />
U<br />
MB<br />
Economy type<br />
Standard type<br />
High-performance type<br />
Ultra current-limiting type<br />
Motor braker<br />
Type name<br />
NV250-SW<br />
NV<br />
C<br />
S<br />
H<br />
U<br />
Economy type<br />
Standard type<br />
High-performance type<br />
Ultra current-limiting type<br />
Number of poles<br />
Number of poles<br />
2P<br />
NV<br />
1ø2W<br />
3P<br />
NF<br />
MB<br />
2P, 3P<br />
3P<br />
3P<br />
3P<br />
NV<br />
1ø2W<br />
1ø3W<br />
3ø3W<br />
Rated current<br />
200A<br />
Even for adjustable rated current<br />
models, the working current should be<br />
specified.<br />
Rated current<br />
200A<br />
4P<br />
NV<br />
3ø4W<br />
Even for adjustable rated current<br />
models, the working current should be<br />
specified.<br />
Rated voltage<br />
Secify DC voltage when for use in<br />
DC circuit<br />
Rated voltage<br />
AC230-400-440V<br />
AC230-400-440V<br />
<br />
Specify the applicable marine<br />
standards<br />
∗ “CE” is standard.<br />
Rated sensitivity<br />
current<br />
100 • 300 • 500mA<br />
30 • 100 • 500mA<br />
100 • 300 • 500mA<br />
Connection<br />
method<br />
B<br />
F<br />
SL<br />
B<br />
PM<br />
Front connection<br />
Solderless (box) terminal<br />
Rear connection<br />
Pulg-in<br />
Connection<br />
method<br />
B<br />
F<br />
SL<br />
B<br />
PM<br />
Front connection<br />
Solderless (box) terminal<br />
Rear connection<br />
Pulg-in<br />
Internal<br />
accessories<br />
AL, SHT (AC110V)<br />
External<br />
accessories<br />
Quantity<br />
10<br />
AL<br />
AX<br />
SHT<br />
UVT<br />
PAL<br />
SLT<br />
INT<br />
MD<br />
F • S • V<br />
S • I • W<br />
MI<br />
TC<br />
LC • HL<br />
HL-S<br />
CH<br />
Alarm switch<br />
Auxiliary switch<br />
Shunt trip<br />
(Specify rated coil voltage.)<br />
Under voltage trip<br />
(Specify rated coil voltage.)<br />
Pre-alarm module<br />
Lead-wire terminal block<br />
Internal terminal type<br />
Electrical operation device<br />
Operating handle<br />
Enclosure box<br />
Mechanical interlock<br />
Terminal cover<br />
(TC-L, TC-S, TTC, BTC)<br />
Handle lock device<br />
Card holder<br />
Type of residual<br />
carrent protection<br />
Internal<br />
accessories<br />
AX, SLT, TBM<br />
External<br />
accessories<br />
Quantity<br />
10<br />
Blank<br />
Specify<br />
AL<br />
AX<br />
UVT<br />
MG<br />
EAL<br />
TBM<br />
PAL<br />
SLT<br />
MD<br />
F • S • V<br />
S • I • W<br />
MI<br />
TC<br />
High-speed type<br />
Time-delay type<br />
Alarm switch<br />
Auxiliary switch<br />
Shunt trip<br />
Insulation switch<br />
Earth-leakage circuit alarm switch<br />
Test button module<br />
Pre-alarm module<br />
Lead-wire terminal block<br />
Electrical operation device<br />
Operating handle<br />
Enclosure box<br />
Mechanical interlock<br />
Terminal cover<br />
(TC-L, TC-S, TTC, BTC)<br />
LC • HL<br />
HL-S<br />
Handle lock device<br />
CH<br />
Card holder<br />
62