3B Scientific - Biology Catalog
3Bscientific.com
3Bscientific.com
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>3B</strong> NETlog<br />
9982-1000578<br />
Relative Pressure Sensor, ±100 hPa<br />
(not shown)<br />
Measurement range: 0 – ±100 hPa<br />
Accuracy: ± 1%<br />
Sensor type: Semiconductor sensor<br />
Hose nipple: 4 mm dia.<br />
Silicone tube: 1 m<br />
9982-1000547<br />
Absolute Pressure Sensor, 2500 hPa<br />
(not shown)<br />
Measurement range: 0 – 2500 hPa<br />
Accuracy: ±1%<br />
Resolution: 1 hPa<br />
Sensor type: Semiconductor sensor<br />
Hose nipple: 4 mm dia.<br />
Plastic syringe: 20 ml<br />
Silicone tube: 1 m<br />
9982-1000546<br />
Blood Pressure Sensor<br />
Sensor box for measuring blood pressure of a<br />
test subject using the oscillometric method with<br />
the aid of a cuff to fit around the extremities. It<br />
is possible to determine the highest systolic and<br />
lowest diastolic pressures, evaluate of pulse rate<br />
by means of an acoustic sensor and illustrate the<br />
Korotkov sound.<br />
Pressure range: 0 mm Hg to 300 mm Hg<br />
(0 to 400 hPa)<br />
Overload-proof: Up to 1500 hPa<br />
Sensor type: Precision pressure sensor,<br />
calibrated and temperature<br />
compensated<br />
9982-1000578<br />
Relative Pressure Sensor, ±1000 hPa<br />
(not shown)<br />
Measurement range: 0 – ±1000 hPa<br />
Accuracy: ± 1%<br />
Sensor type: Semiconductor sensor<br />
Hose nipple: 4 mm dia.<br />
Silicone tube: 1 m<br />
9982-1000548<br />
Microphone (not shown)<br />
Frequency range: 50 Hz – 20 kHz<br />
Microphone cable: 2 m<br />
9982-1000565<br />
pH Sensor (not shown)<br />
Measurement range: pH 0 – 14<br />
Sensor type: Ag-AgCl combination<br />
electrode, gel filled,<br />
not refillable<br />
Accuracy:<br />
pH 0.05 in range from<br />
20°C – 25°C<br />
Resolution: pH 0.01<br />
Response time: ≤ 1 s to reach 95% of final<br />
value<br />
9982-1000556<br />
Additionally recommended:<br />
9982-1002753 Buffer Solution<br />
Buffer Solution (not shown)<br />
Set of buffer solutions in three flasks with pH<br />
values of 4.00, 7.00 and 9.00.<br />
Volume:<br />
250 ml each<br />
9982-1002753<br />
9982-1000577<br />
Computer Aided Experimentation<br />
Light Sensor (not shown)<br />
Measurement ranges: 0 − 600 lux, 0 − 6000 lux,<br />
0 − 150,000 lux<br />
Resolution: 0.8 lux, 8 lux, 200 lux<br />
9982-1000562<br />
Temperature Sensor, Pt100 (not shown)<br />
Measurement<br />
range: -50°C – 150°C<br />
Resolution: 0.1 °C<br />
Accuracy:<br />
0.1% of measured value<br />
plus 0.25°C<br />
Sensor cable: 1 m, with silicone<br />
insulation<br />
Sensor type: Pt100 thermocouple<br />
9982-1000550<br />
Humidity Sensor (not shown)<br />
Measurement range: 0 – 95% (non condensing)<br />
Sensor type: Capacitive sensor<br />
Accuracy:<br />
3% of RH plus 1% in the<br />
range from 0% –95%<br />
5% of RH plus 1% in the<br />
range from 0% –5%<br />
Resolution: 0.1%<br />
Response time: 15 s<br />
9982-1000554<br />
Conductivity Sensor (not shown)<br />
Measurement ranges: 0 – 200 µS, 0 – 2 mS,<br />
0 – 20 mS<br />
Resolution: 1 µS, 10 µS, 100 µS<br />
Sensor type: Measurement electrode<br />
using four wire tech nology,<br />
with graphite cells and<br />
integrated Pt100 temperature<br />
sensor<br />
Accuracy:<br />
5% without calibration,<br />
0.5% with calibration<br />
Sensor cable: 1.5 m<br />
9982-1000553<br />
Human Pulse Sensor Box (not shown)<br />
Measurement range: Pulse rates from 40 − 160<br />
beats/min<br />
Safety category: Safety class II,<br />
classification BF<br />
9982-1000575<br />
Barometer (not shown)<br />
Measurement range: 700 hPa – 1200 hPa<br />
Resolution: 0.1 hPa<br />
Accuracy:<br />
1.5% of the maximum<br />
value of the measuring<br />
range<br />
Sensor type: Semiconductor sensor<br />
9982-1000549<br />
Skin Resistance Box (not shown)<br />
Measurement range: 1 MΩ – 10 MΩ<br />
Input resistance: >100 kΩ<br />
Safety category: Safety class II,<br />
classification BF<br />
9982-1000576<br />
9982-1000579<br />
Response Box<br />
Microprocessor-controlled box with a foot switch<br />
and three coloured finger-operated buttons<br />
(blue, green and red) and a combined LED, which<br />
can light up in the same colours as the hand<br />
buttons or in white to indicate use of the foot<br />
switch. Once the LED has lit up in some arbitrary<br />
colour, the response time before the appropriate<br />
switch has been activated is measured. For use<br />
in conjunction with <strong>3B</strong> NETlog unit (9982-<br />
1000540/9982-1000539) for manual measurements<br />
or measurement acquisition via computer.<br />
Includes connector lead with 8-pin miniDIN<br />
plugs.<br />
Duration of measurement: max. 9.2 s<br />
Display resolution: 1/100 s<br />
Footswitch connector: 3.5 mm jack plug<br />
9982-1000577<br />
ECG/EMG Box<br />
Sensor box for reading electrocardiograms (ECGs)<br />
and electromyograms (EMGs) on skeletal musculature<br />
in three standard leads as defined by<br />
Einthoven. Feeds can be selected at the press of<br />
a button and are indicated by LEDs.<br />
Input resistance:<br />
> 10 MΩ<br />
Output voltage:<br />
max. ± 1 V<br />
Blocked frequency: 50 – 60 Hz<br />
9982-1000579<br />
122<br />
<strong>3B</strong> <strong>Scientific</strong>® <strong>Biology</strong>