Hydrostatic Test Plug<br />
Hydrostatic Test Plugs<br />
For buttweld inlet valves shipped, hydrostatic test plugs are normally installed to increase “set point”<br />
approximately 1.5 times the valve set pressure for hydrostatic testing. It is strongly recommended that<br />
hydrostatic test plugs be used, in conjunction with proper gag and gagging procedure, during hydrostatic<br />
testing to avoid valve component damage.<br />
For flanged inlet valves shipped, hydrostatic test plugs are not normally installed. It is suggested that<br />
the valve not be installed until after the unit hydrostatic test has been performed utilizing “blind”<br />
flanges to blank-off the unit nozzles.<br />
Note 1: Hydrostatic plugs may be added or deleted upon specific request.<br />
Note 2: Consult maintenance manual for hydrostatic test and gag procedures.<br />
<strong>1700</strong><br />
Inlet Type<br />
Flanged<br />
Inlet<br />
Buttweld<br />
Inlet<br />
Hydrostatic Test Plugs (Note 1)<br />
Installed Before Shipping<br />
No<br />
Yes<br />
<strong>1700</strong><br />
Valves shipped with hydroplug are<br />
identified by a Red on White Caution Tag<br />
which is attached to the valve by wires<br />
extending through the drain hole in the<br />
valve body.<br />
<strong>1700</strong>.67