Operation Section 3<br />

<strong>MDH</strong>-<strong>302</strong> Cold Carbonation System<br />

020003743<br />

PLAIN WATER<br />

TO MANIFOLD<br />

(NON-INSULATED)<br />

NON-CARBONATED WATER<br />

TO WATER INLETS ON UNIT<br />

(NON-INSULATED) FROM<br />

CARBONATOR PUMP<br />

NOTES:<br />

- COLD CARBONATION DECK MUST<br />

BE WITHIN 10 FEET OF UNIT TO<br />

FUNCTION PROPERLY.<br />

- COLD CARBONATION DECK MUST<br />

BE PLACED ON A LEVEL SURFACE.<br />

CARBONATED<br />

WATER<br />

TO MANIFOLD<br />

(INSULATED)<br />

- COLD CARBONATION DECK REQUIRES<br />

BOOSTER SYSTEM IF SUPPLY DYNAMIC WATER<br />

PRESSURE IS BELOW 40 PSI, OR, IF TWO<br />

UNITS ARE INSTALLED ON THE SAME<br />

WATER LINE.<br />

- FILTRATION SYSTEM SHOULD BE PLACED<br />

AFTER BOOSTER PUMP.<br />

(PER CUSTOMER SPECIFICATIONS)<br />

- ITEMS HAVE BEEN REMOVED FOR CLARITY<br />

-12 VALVE UNIT IS SHOWN<br />

<strong>MDH</strong>-<strong>302</strong><br />

COLD WATER TO<br />

CARBONATOR TANK<br />

(INSULATED)<br />

COLD WATER TO<br />

CARBONATOR TANK<br />

(INSULATED)<br />

NON-CARBONATED WATER<br />

TO WATER INLETS ON UNIT<br />

(NON-INSULATED) FROM<br />

CARBONATOR PUMP<br />

CO2 REGULATOR<br />

FIXED AT 75 PSI<br />

PLAIN WATER TO<br />

MANIFOLD<br />

(NON-INSULATED)<br />

CARBONATED<br />

WATER<br />

TO MANIFOLD<br />

(INSULATED)<br />

FOR SERIALS PRIOR TO 610115880<br />

NON-CARBONATED WATER<br />

TO WATER INLETS ON UNIT<br />

(NON-INSULATED) FROM<br />

CARBONATOR PUMP<br />

FITTING NOT USED<br />

INSTALL 3/8 CAP NUT<br />

PART # 3094 AND<br />

WASHER 1701115<br />

FOR TANK PRESSURES<br />

REFER TO MANUAL<br />

FOR SPECIFICATIONS<br />

WATER FROM BOOSTER<br />

TO PUMP INLET<br />

COLD CARBONATION DECK<br />

CO2 SUPPLY<br />

100 PSI MIN.<br />

REGULATOR<br />

50-55 PSI<br />

Typical <strong>MDH</strong>-<strong>302</strong> Cold Carbonation Beverage Dispensing System<br />

CUT-IN 70 PSI<br />

CUT-OUT 100 PSI<br />

MUNICIPAL WATER SUPPLY<br />

BOOSTER SYSTEM<br />

3-2 Part Number 020003999 4/12<br />

FILTRATION<br />

SYSTEM