WELDING MACHINES<br />

Plasma cutting Inverters<br />

Most metals and their alloys can be cut with a plasma cutting system This is a polarized air flow under high pressure, comprising compressed<br />

air, polarized by a powerful source of polarization (with 70% nitrogen) and directed <strong>to</strong> the work piece through a calibrated nozzle. A strong yet<br />

slim jet of polarized air in the form a cutting arc with the temperature of 20.000°C melts the surface and penetrates deep in<strong>to</strong> the material<br />

and blows out the melt. All that is left is a clean cut, a small amount of melt and the overheated surface reduced <strong>to</strong> minimum. For easier arc<br />

ignition plasma cutting inverters are equipped with high frequency or mains electric arc (depending on the model).<br />

Rheinland Elektro <strong>Maschinen</strong> Plasma cutting Inverters with their modern technology enable simple, fast and low cost metal cutting. Due <strong>to</strong><br />

small dimensions they are indispensable in metalworking shops and other workshops, outdoor work and high altitude cutting. All plasma<br />

cutting Inverters are equipped with <strong>to</strong>rches, pressure regula<strong>to</strong>rs, condensation reservoir and au<strong>to</strong>matic air switch.<br />

STANDARD EQUIPMENT:<br />

• Torch<br />

• Pressure regula<strong>to</strong>r<br />

• Condensate reservoir<br />

• Au<strong>to</strong>matic air switch<br />

Technical specification<br />

MODEL<br />

Plasma<br />

312<br />

ORDER NUMBER 303550312 304040412 2304040412 309140930<br />

MAIN VOLTAGE (V/%) 230 ± 10 230 ± 10 400 ± 10 400 ± 10<br />

OUTPUT RANGE (A) 270 280 250 250<br />

MAIN FUSE (A) 15 16 20 20<br />

DUTY CYCLE (A-%) 35-35 40-40 70-60 90-40<br />

NOMINAL POWER (kW) 4,1 4,8 11,2 15,3<br />

POWER FACTOR (COS φ) 0,85 0,85 0,85 0,85<br />

ELECTRIC ARC IGNITION Pilot Arc without HF Pilot Arc with HF Pilot Arc without HF Pilot Arc with HF<br />

PROTECTION CLASS IP 21 S IP 21 S IP 21 S IP 21 S<br />

ISOLATION CLASS F F F F<br />

PLASMA OUTPUT RANGE (A) 15 - 35 15 - 40 1 - 70 26 - 90<br />

OPERATING TEMPERATURE RANGE (°C) - 10 <strong>to</strong> + 40 - 10 <strong>to</strong> + 40 - 10 <strong>to</strong> + 40 - 10 <strong>to</strong> + 40<br />

FREQUENCY (Hz) 50/60 50/60 50/60 50/60<br />

QUALITY CUT (mm) 10 12 20 25<br />

SEVERANCE (mm) 12 14 25 30<br />

DIMENSIONS (mm) 150×480×225 180×460×230 180×470×250 180×485×285<br />

WEIGHT (kg) 10 14,7 14,7 15,5<br />