- 16 -<br />

through a heat exchanger, where a subcooling takes place.<br />

The secondary cooling fl.w through the heat exchanger is<br />

measured by one <strong>of</strong> two flowmeters. The primary flow, the total<br />

suction rate, is measured by one <strong>of</strong> three flowmeters (venturi<br />

or orifice) <strong>and</strong> one <strong>of</strong> -hree dp-cells. The measuring range is<br />

from 10 g/s to 350 g/s with an accuracy <strong>of</strong> • 1.5%.<br />

After the total suction rate is measured, the primary flow<br />

is returned to the regenerator, where it is reheated. Finally,<br />

it is returned to the main system through the ejector pump at<br />

VI on fig. 3.1.<br />

From the measured flow rates <strong>and</strong> temperatures T 2 to T,_,<br />

the film flow rate can be determined as described in sect.<br />

3.2.2.<br />

When the film flow rates on the rod <strong>and</strong> tube wall in the<br />

annular test section are determined, two heat balance units are<br />

used. However, the measurements were not carried out simultaneously<br />

because the opposite film might be disturbed.<br />

3.1.3. Test Sections<br />

The following test sections were used during the experimental<br />

periods (cf. table 3.2):<br />

where<br />

Period 1: <strong>An</strong>nular test section 17/26S<br />

dj = 0.017 m, d 2 = 0.026 m, 1 = 3.5 m<br />

Periods 2-4: Tubular test .section 10<br />

d_ = 0.010 m, 1 = 9.0 m<br />

Period 5: <strong>An</strong>nular test section 17/26L<br />

d. = 0.017 m, d_ = 0.026 m, 1 = 8.0 m<br />

Period 6: Tubular test section 20<br />

d_ = 0.020 m, 1 = 9.0 m<br />

d, (m) is the outer diameter <strong>of</strong> the rod<br />

d- (ni) is the inner diameter <strong>of</strong> the tube<br />

1 (in) is the length <strong>of</strong> the test section<br />

In the adiabatic experiments (periods 2, 5 <strong>and</strong> 6) the experimental<br />

set-up consisted in addition to the test section, <strong>of</strong> a<br />

steam generator placed between the flowmeter <strong>and</strong> the inlet<br />

flange at the test section.<br />

The steam generator is electrically heated as a resistance<br />

element. It consists <strong>of</strong> nine tubes (d 2 = 0.0063 m, 1 = 4.0 m)