- 18 -<br />

3.1..j. ~ > . Tabular Test Sections 10 <strong>and</strong> 20. The tubular<br />

test section 20, with an inner diameter <strong>of</strong> 20 mm, is shown in<br />

fig. 3.5.<br />

The siK-1ion area is made in the same manner as in the annular<br />

test section. Both the upper <strong>and</strong> the lower power clamps are<br />

movable for the whole length <strong>of</strong> the tube. The wall is provided<br />

with holes for needle contact probes <strong>and</strong> tubes for pressure-drop<br />

measurements.<br />

The tubular test section 10 is constructed in the same way<br />

as test section 20.<br />

3.1.4. Power Supplies<br />

The electrical power to the test sections <strong>and</strong> steam generator<br />

is delivered from two 250 kW thyristor-controlled dc power<br />

supplies <strong>and</strong> one 165 kW vario transformer.<br />

The dc power supplies are ASEA type YNVD, giving 100 V,<br />

2500 A each. Because <strong>of</strong> severe problems with electric noise in<br />

the measuring channels, it was necessary to install two filterinductances<br />

to reduce the superimposed ac-components from these<br />

supplies. (Cf. Cortzen (1976)). Each <strong>of</strong> the filters has an inductance<br />

<strong>of</strong> 150 ull at 250 A <strong>and</strong> 34 utt at 2500 A.<br />

3.1.5. Pressure-Drop Measurement Equipment<br />

The axial pressure gradient in the test sections was determined<br />

by means <strong>of</strong> electric differential pressure transducers<br />

(dp-cells), type Rosemount model 1151 DP.<br />

The pressure range is -10 kPa to + 190 kPa with an accuracy<br />

<strong>of</strong> ± C.5 kPa.<br />

In the annular test sections, there are 8 pressure taps<br />

placed 0.5 m apart. The upper pressure tap is placed immediately<br />

below the outlet, the lowest 3.5 m below. The partial pressure<br />

drops between the taps <strong>and</strong> the total pressure drop were measured<br />

by means <strong>of</strong> 8 dp-cells.<br />

In the tubular test sections, the pressure taps located from<br />

the outlet <strong>and</strong> down to 1.0 m below are placec 0.25 m apart. From<br />

1.0 m to 4.0 m below, the distance between the taps is 0.5 m.<br />

Thus, in the tubular test section, 1 total <strong>and</strong> 10 partial pressure<br />

drops were measured.