29.06.2014 Views

SCOTSMAN EUROPE SERVICE DEPARTMENT

SCOTSMAN EUROPE SERVICE DEPARTMENT

SCOTSMAN EUROPE SERVICE DEPARTMENT

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SCOTSMAN</strong> <strong>EUROPE</strong> <strong>SERVICE</strong> <strong>DEPARTMENT</strong><br />

SP-09.08 – APRIL ‘09<br />

MV 456-606-806-1006<br />

WATER LEVEL SENSOR<br />

HARNESS<br />

We would like to inform you that under some very rare circumstances, the Water Level<br />

Sensor of the new MV ..6 series can switch off the water inlet valve with a very low<br />

level of water into the water reservoir (water level corresponding to the longer water<br />

sensor finger).<br />

This can happen when the Water Level Sensor Harness have the two wires connected on<br />

reverse and water is dripping onto the Ice Thickness Sensor at the beginning of the<br />

freezing cycle.<br />

If so, the signal transmitted to the PC Board through<br />

the Ice Thickness Sensor is equivalent to have the<br />

water reservoir full of water tripping OFF the water<br />

inlet solenoid valve.<br />

In this condition the machine operates into the freezing<br />

cycle with a very low level of water tripping OFF 40<br />

minutes later with the Red Alarm Led of the Too Long<br />

Harvest cycle ON.<br />

To overcome the problem the Water Level Sensor<br />

Harness must be replace with the correct one (see<br />

beside drawing and below photo) available under Part<br />

Nbr CM 81455102.