Page 4 — CATALOG 410A<br />
Thermostatic Expansion Valves<br />
410A<br />
Type RCZE<br />
Knife Edge Joint<br />
Standard Cap Tube Length 30 in. (76 cm)<br />
1.94”<br />
49 mm<br />
Cap Tube<br />
30”<br />
76 cm<br />
The RCZE valve is an externally adjustable<br />
balance ported TEV with an internal<br />
check valve for heat pump applications. This<br />
makes the RCZE valve an excellent replacement<br />
for all OEM CBI and CBBI valves as<br />
Type<br />
RCZE<br />
well as other applications requiring a R-410A expansion valve on heat<br />
pumps. The RCZE valve may also be used on air conditioning (cooling<br />
only) applications. This allows you to reduce inventory to also<br />
replace the I, RI, BI and BBI valves. The RCZE valves utilize the<br />
KT-45 element design for the higher pressures of R-410A systems.<br />
3.66”<br />
93 mm<br />
2.30”<br />
58 mm<br />
1.81”<br />
46 mm<br />
D<br />
Dimensions<br />
Connections<br />
VALVE<br />
TYPE<br />
RCZE-<br />
1, 1-1/2 & 2<br />
RCZE-<br />
3, 4, 5 & 6<br />
FITTING SIZE<br />
Inches<br />
Inches<br />
mm<br />
A B A B<br />
3/8 ODF 1.92 1.45 48.8 36.8<br />
1/2 ODF 1.98* 1.45 50.3 36.8<br />
5/8 ODF – 1.53 – 38.9<br />
3/8 ODF 1.92 1.45 48.8 36.8<br />
1/2 ODF 1.98 1.45 50.3 36.8<br />
5/8 ODF – 1.53 – 38.9<br />
RCZE Chatleff Fitting 1.89 1.71 48.0 43.4<br />
*1/2 ODF inlet available on 2 ton valves only.<br />
Chatleff<br />
Fitting Option<br />
A<br />
B<br />
Top View<br />
1/4” ODF<br />
1.90”<br />
48 mm<br />
C<br />
30°<br />
Bulb Sizes<br />
THERMOSTATIC Inches mm<br />
CHARGE C D C D<br />
ZCP200 0.50 3.00 13 76<br />
ZGA 0.75 2.00 19 51<br />
Capacities<br />
Tons n psi n °F kW n bar n °C<br />
VALVE<br />
TYPE<br />
NOMINAL<br />
CAPACITY<br />
(Tons)<br />
EVAPORATOR TEMPERATURE °F<br />
40 20 0<br />
PRESSURE DROP ACROSS VALVE (psi)<br />
160 200 200<br />
RCZE-1-GA 1 1.2 1.3 1.2<br />
RCZE-1-1/2-GA 1-1/2 2.1 2.3 2.0<br />
RCZE-2-GA 2 2.7 3.0 2.7<br />
RCZE-3-GA 3 3.8 4.1 3.7<br />
RCZE-4-GA 4 5.0 5.4 4.9<br />
RCZE-5-GA 5 5.9 6.5 5.8<br />
RCZE-6-GA 6 7.1 7.8 6.3<br />
VALVE<br />
TYPE<br />
NOMINAL<br />
CAPACITY<br />
(kW)<br />
EVAPORATOR TEMPERATURE °C<br />
5 -5 -15<br />
PRESSURE DROP ACROSS VALVE (bar)<br />
11 14 14<br />
RCZE-1-GA 4.20 4.20 4.64 4.25<br />
RCZE-1-1/2-GA 7.35 7.35 8.11 7.44<br />
RCZE-2-GA 9.66 9.66 10.7 9.77<br />
RCZE-3-GA 13.4 13.4 14.8 13.6<br />
RCZE-4-GA 17.6 17.6 19.5 17.8<br />
RCZE-5-GA 21.0 21.0 23.2 21.2<br />
RCZE-6-GA 25.2 25.2 27.8 23.7<br />
LIQUID TEMPERATURE ENTERING TEV °F<br />
40 50 60 70 80 90 100 110 120 130 140<br />
CORRECTION FACTOR, CF LIQUID TEMPERATURE<br />
1.39 1.31 1.23 1.17 1.12 1.06 1.00 0.94 0.88 0.82 0.76<br />
EVAPORATOR<br />
TEMPERATURE<br />
°F<br />
PRESSURE DROP ACROSS TEV (psi)<br />
80 120 160 200 240 280 320 360<br />
CORRECTION FACTOR, CF PRESSURE DROP<br />
0° 0.71 0.87 1.00 1.12 1.22 1.32 1.41 1.50<br />
20° 0.63 0.77 0.89 1.00 1.10 1.18 1.26 1.34<br />
40° 0.63 0.77 0.89 1.00 1.10 1.18 1.26 1.34<br />
LIQUID TEMPERATURE ENTERING TEV °C<br />
5 10 15 20 25 30 35 40 45 50 55 60<br />
CORRECTION FACTOR, CF LIQUID TEMPERATURE<br />
1.46 1.39 1.32 1.25 1.18 1.11 1.04 0.97 0.89 0.81 0.72 0.62<br />
EVAPORATOR<br />
TEMPERATURE<br />
°C<br />
PRESSURE DROP ACROSS TEV (bar)<br />
8 10 11 12 13 14 16 18 20<br />
CORRECTION FACTOR, CF PRESSURE DROP<br />
5° 0.85 0.95 1.00 1.04 1.09 1.13 1.21 1.28 1.35<br />
-5° 0.76 0.85 0.89 0.93 0.96 1.00 1.07 1.13 1.20<br />
-15° 0.76 0.85 0.89 0.93 0.96 1.00 1.07 1.13 1.20