FAULT FINDING GUIDE<br />
FAULT POSSIBLE CAUSE ACTION<br />
FATAL I 2 C ERROR<br />
displayed<br />
(a)<br />
(b)<br />
Electrical noise<br />
MPU Board fault<br />
(a)<br />
(b)<br />
Check motors<br />
Replace MPU Board<br />
(c)<br />
Software error<br />
(c)<br />
Reset power<br />
Keypad does not bleep (a) Keypad damaged<br />
(a)<br />
Replace keypad<br />
(b)<br />
Keypad disconnected<br />
(b)<br />
Reconnect<br />
(c)<br />
MPU Board fault<br />
(c)<br />
Replace MPU Board<br />
Drinks cold (a) Heater fuse blown<br />
(a)<br />
Check and replace<br />
(b)<br />
Thermal cut-out tripped<br />
(b)<br />
Reset trip<br />
(c)<br />
Desired temperature<br />
incorrectly set<br />
(c)<br />
Check desired temperature<br />
setting<br />
(d)<br />
Excessive scaling in heater<br />
tank<br />
(d)<br />
Check tank and descale if<br />
necessary<br />
(e)<br />
Solid state relay fault<br />
(e)<br />
Check relay<br />
(f)<br />
Low cut-out in program<br />
incorrectly set<br />
(f)<br />
Reset low cut-out setting<br />
(g)<br />
Temperature probe wet<br />
(g)<br />
Dry probe and check<br />
for leaks.<br />
No motor operation (a) Jammed motor<br />
(a)<br />
Check motor operation<br />
(b)<br />
Power Supply failure<br />
safety trip<br />
(b)<br />
Reset power<br />
Machine inoperable;<br />
no display<br />
(a)<br />
Power Supply failure<br />
(a) Replace Power Supply<br />
Board<br />
NEVA 3 Issue 1 30/07/07 36