Chapter 2. Partitioning and Configuring the <strong>Library</strong><br />

Saving Ethernet Parameters<br />

Before any configuration changes can take effect it is necessary to reset the G2 E-QIP<br />

board. This can be accomplished through the <strong>Library</strong> Controller. Configuration changes<br />

that require a reset include:<br />

•When any Ethernet parameter is changed.<br />

•When an Ethernet protocol is enabled or disabled.<br />

•When a library partition is modified.<br />

•When any protocol configuration parameter is changed.<br />

•When any port mapping or target visibility is changed.<br />

Reset the G2 E-QIP<br />

To reset the G2 E-QIP follow the following procedure:<br />

1. From the Maintenance Toolbar select Diagnostic (Figure 2-20).<br />

o<br />

Figure 2-20 The <strong>Library</strong> Diagnostic seen.<br />

46