01.11.2014 Views

Biphasic Cuirass Ventilation

Biphasic Cuirass Ventilation

Biphasic Cuirass Ventilation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

External High-Frequency Oscillation for Hypercapnia<br />

after Upper Abdominal Surgery<br />

Shinhiro Takeda 1 , Kazuhiro Nakanishi 1 , Teruo Takano 1 , Jun Nejima 1 , Morimasa Takayama 1 ,<br />

Atsuhiro Sakamoto 2 and Ryo Ogawa 2<br />

1<br />

Division of Intensive Care and Coronary Care Unit and 2 Department of Anaesthesiology<br />

Nippon Medical School, Tokyo, Japan<br />

Seven patients were ventilated with EHFO for 2 hr at 60 oscillations/min, with cuirass<br />

pressures of 36 cm H 2<br />

O (-26 to +10), and an inspiratory to expiratory ratio of 1:1. Blood gases and<br />

cardiac functional parameters were examined during the 2 hr on EHFO.<br />

PaCO 2<br />

significantly decreased from 61+8 mm Hg to 48+7 mm Hg after 10 min on<br />

EHFO (p