RINN XCP X-Ray Alignment Instruments<br />

XCP ® Evolution Kit<br />

(X-ray beam alignment)<br />

• XCP Kit with bitewing instrument<br />

• 4 arms: 1x anterior, 2x posterior, 1x bitewing<br />

• 4 rings: 1x anterior, 2x posterior, 1x bitewing<br />

• 17 biteblocks: 4x anterior, 8x posterior, 5x bitewing<br />

(2x H#2, 1x V#2, 1x H #0/1, 1x V#1)<br />

• Instructional poster.<br />

R542001<br />

Evolution Kit (X-ray beam alignment)<br />

XCP ® Evolution Kit (X-ray beam<br />

alignment) with Endodontic Instrument<br />

XCP Kit with bitewing and endodontic instruments.<br />

Includes all the contents of R542001, plus 1x endo ring,<br />

1x endo arm, and 4x endo biteblocks.<br />

R542003<br />

Evolution Kit (X-ray beam alignment) with<br />

Endodontic Instrument<br />

Film Holder EndoRay II<br />

Bitewing Tabs Film<br />

Sold in a pack of 500.<br />

R140500<br />

Bitewing Tabs #0.1 Film<br />

Bitewing Loops Film<br />

Sold in a pack of 500.<br />

Prevent cone cutting with precise angulation and alignment of<br />

film to x-ray cone. Fits over files, clamps and rubber dams.<br />

Use for endodontic radiography without touching the subject<br />

tooth. Paralleling technique. Use with #1 or #2 film. Steam<br />

autoclave. Sold in a pack of 2.<br />

R141026 500x Bitewing Loops #0.1Film<br />

R141027 500x Bitewing Loops #2 Film<br />

R143027 1500x Bitewing Loops #2 Film<br />

Universal Collimator<br />

R540303<br />

Film Holder EndoRay II<br />

Positioning Accessories for Film<br />

Holder EndoRay II<br />

Sold indiviually.<br />

R540310<br />

R540311<br />

R540312<br />

EndoRay Arm<br />

EndoRay Basket<br />

EndoRay Ring<br />

Align the beam and prevent misfocusing of x-rays by<br />

absorbing divergent radiation, and prevent radiation leakage.<br />

Use in conjunction with XCP, XCP-DS, BAI or EndoRay II<br />

Positioning Systems for accurate alignment. Protect your<br />

patients by limiting the size of the primary x-ray beam to #2<br />

film. Quickly applies into open end of round PID. Vertical or<br />

horizontal use. Sold individually.<br />

R540853<br />

Universal Collimator<br />