4. Trial Operation<br />
4.5 Auto-Tuning<br />
Parameters such as stator resistance (Rs), stator leakage inductance (sL ), flux current (IF), rotor time<br />
constant (τr) and stator self-inductance (Ls) are indispensable for obtaining an excellent control<br />
performance in the vector control and are automatically measured and set using auto-tuning function.<br />
■ SV-<strong>iV5</strong> features two types of Auto-tuning: 1) Rotational Auto Tuning<br />
2) Standstill Auto Tuning<br />
4.5.1 Motor & encoder parameter setting for auto-tuning<br />
The Motor capacity, Basic speed, Rating voltage, Pole number, Efficiency, Rating slip and Rating current on<br />
the nameplate of the motor and the pulse number of encoder should be set before operation.<br />
LCD Display Description<br />
PAR▶ Motor select<br />
07 kW<br />
PAR▶ UserMotorSel<br />
08 kW<br />
PAR▶ Enc Pulse<br />
10 [][][]<br />
PAR▶ Base Speed<br />
17 rpm<br />
PAR▶ Rated Volt<br />
18 V<br />
PAR▶ Pole number<br />
19 []<br />
PAR▶ Efficiency<br />
20 %<br />
PAR▶ Rated-Slip<br />
21 rpm<br />
PAR▶ Rated-Curr<br />
22 A<br />
� Enter the motor capacity.<br />
� Basic capacity is same with Inverter capacity<br />
� Enter directly in the PAR_08 after selecting “User<br />
Define” if there is no Motor capacity.<br />
� Enter the motor capacity directly at PAR_08 incase<br />
that select “User Define” at PAR_07<br />
� Set the pulse numbers per revolution of pulse<br />
encoder coupled to the motor shaft.<br />
� Set the motor base speed.<br />
Note) It is not rating current of name plate.<br />
Base Speed = 120 X Base Frequency/ Pole number<br />
� Set the rated voltage of the motor.<br />
(Voltage value on the name plate)<br />
� Set the number of poles of the motor.<br />
� Set the efficiency of the motor. If you cannot find<br />
the efficiency in name plate, Do not set the<br />
Efficiency.<br />
� Set the rated slip speed of the motor.<br />
(Rated slip=synchronous speed–rated speed)<br />
� Set the rated current of the motor.<br />
4-6