Code<br />

No.<br />

Comm.<br />

Addr<br />

FUN_55 7437<br />

FUN_56 7438<br />

FUN_57 7439<br />

CODE NAME<br />

Electronic thermal level<br />

for 1 minute<br />

Electronic thermal level<br />

for continuous<br />

Switching frequency<br />

select<br />

LCD<br />

DISPLAY<br />

SETTING DATA<br />

RANGE UNIT DEFAULT<br />

5. Function Code Table<br />

Adjustment<br />

During Run<br />

ETH 1 min FUN_56 ~ 200 % 150 Yes<br />

ETH Cont<br />

50 ~ FUN_55<br />

(up to 150%)<br />

PWM Freq 2.5 ~ 10.0 kHz<br />

% 100 Yes<br />

Different<br />

according to<br />

the capacity<br />

of inverter<br />

PAGE<br />

6-44<br />

No 6-45<br />

FUN_58 743A Power on Run selection Power-on Run<br />

0 (No)<br />

1 (Yes)<br />

- 0 (No) Yes 6-46<br />

FUN_59 743B Restart after fault reset RST Restart<br />

0 (No)<br />

1 (Yes)<br />

- 0 (No) Yes 6-47<br />

FUN_60<br />

FUN_61<br />

743C<br />

743D<br />

Number of auto restart<br />

try<br />

Delay time before Auto<br />

restart<br />

Retry Number<br />

Retry Delay<br />

0 ~ 10<br />

0.0 ~ 60.0<br />

-<br />

sec<br />

0<br />

1.0<br />

Yes<br />

Yes<br />

6-48<br />

FUN_62 743E<br />

Wait time for Restart<br />

upon Stop<br />

Restart Time 0.00 ~ 10.00 sec 0.00 No<br />

FUN_63 743F<br />

Overspeed Detection<br />

Level<br />

OverSpdLevel 100.0 ~ 130.0 % 120.0 No 6-49<br />

FUN_64 7440<br />

Overspeed Detection<br />

Time<br />

OverSpd Time 0.00 ~ 2.00 sec 0.00 No<br />

FUN_65 7441 Brake Open Time 1) BKOpen Time 0.00 ~ 30.00 sec 0.00 No<br />

FUN_66 7442 Brake Open Speed 1) BKOpen Spd 0.0 ~ 500.0 rpm 0.0 No<br />

FUN_67 7443 Brake Open Current 1) Release Curr 0.0 ~ 150.0 % 20.0 No<br />

FUN_68 7444 Brake Close Time 1) BKClose Time 0.00 ~ 30.00 sec 0.00 No<br />

FUN_69 7445 Brake Close Speed 1) 6-50<br />

BKClose Spd 0.0 ~ 500.0 rpm 0.0 No<br />

FUN_70 7446<br />

Speed in batteryoperated<br />

mode 2)<br />

FUN_71 7447<br />

Battery input voltage<br />

Note 2)<br />

Batt. Speed<br />

Batt. Volt<br />

2.5 ~ 200.0<br />

12 ~ PAR_18<br />

rpm<br />

V<br />

50.0<br />

48<br />

No<br />

No<br />

6-52<br />

1) Displayed when setting the definition of multi-aux output terminal (DIO_41~DIO_43) as “Brake Output”.<br />

2) It can set for only 5.5 ~ 22 kW/2/4 products in case ‘Battery Run’ of multi-function input terminal (P1 ~ P&) is turned On.<br />