Waveform <strong>Measuring</strong> <strong>Instruments</strong><br />

Waveform<br />

<strong>Measuring</strong><br />

<strong>Instruments</strong><br />

Waveform <strong>Measuring</strong><br />

Product<br />

PB500<br />

(500 MHz passive probe)<br />

DL Series Accessories List<br />

Part No.<br />

701943<br />

500 MHz BW, 10:1, 1.5 meters<br />

Description<br />

DL9700<br />

DL9000<br />

DL7400<br />

DL1600<br />

DL1700E<br />

PBA2500<br />

(2.5 GHz active probe)<br />

701913<br />

2.5 GHz BW, 10:1, 1.2 meters<br />

PBA1500<br />

(1.5 GHz active probe)<br />

701914<br />

1.5 GHz BW, 10:1, 1.2 meters<br />

PBA1000<br />

(1.0 GHz active probe)<br />

701912<br />

1.0 GHz BW, 10:1, 1.2 meters<br />

PBD 2000<br />

(2 GHz differential probe)<br />

701923<br />

2 GHz BW, 10:1, Max. differential input voltage: ±5 V, 1.2 meters<br />

PBL5000<br />

(5 GHz low<br />

capacitance probe)<br />

400 MHz passive probe<br />

200 MHz passive probe<br />

500 MHz Miniature<br />

passive probe<br />

350 MHz Miniature<br />

passive probe<br />

701974<br />

700988<br />

700960<br />

701941<br />

701942<br />

5 GHz BW, 10:1, 20:1, 0.95 meters<br />

400 MHz BW (10:1)<br />

<strong>All</strong>ows the division ratio to be switched between 10:1 and 1:1.<br />

1.5meters<br />

200 MHz BW (10:1)<br />

<strong>All</strong>ows the division ratio to be switched between 10:1 and 1:1.<br />

1.5meters<br />

DC to 500 MHz, 10:1, 1.2 meters<br />

DC to 350 MHz, 10:1, 3.0 meters<br />

100:1<br />

High voltage probe<br />

701944<br />

400 MHz BW, 100:1, 1.2 meters<br />

100:1<br />

High voltage probe<br />

701945<br />

250 MHz BW, 100:1, 3.0 meters<br />

900 MHz FET Probe<br />

700939<br />

DC to 900 MHz, Input impedance 1.8 pF<br />

Logic probe<br />

Logic probe<br />

100 MHz<br />

differential probe<br />

200 MHz<br />

differential probe<br />

15 MHz<br />

differential probe<br />

100 MHz<br />

differential probe<br />

500 MHz<br />

differential probe<br />

Deskew signal source<br />

Current probe<br />

Current probe<br />

Current probe<br />

701980<br />

701981<br />

701921<br />

701922<br />

700925<br />

700924<br />

701920<br />

701935<br />

701933<br />

701930<br />

701931<br />

Input impedance: 1 MΩ<br />

Max. toggle frequency: 100 MHz<br />

Input impedance: 10 KΩ<br />

Max. toggle frequency: 250 MHz<br />

DC~100 MHz, 10:1, 100:1,<br />

Max. differential input voltage: ±70 V (10:1), ±700 V (100:1)<br />

DC~200 MHz, 10:1,<br />

Max. differential input voltage: ±20 V<br />

DC~15 MHz, 10:1, 100:1,<br />

Max. differential input voltage: ±500 V (100:1), ±50 V (10:1)<br />

DC~100 MHz, 100:1, 1000:1,<br />

Max. differential input voltage: ±1400 V (1000:1), ±350 V (100:1)<br />

DC~500 MHz, 10:1,<br />

Max. differential input voltage: ±12 V<br />

Output voltage: Approx. 0-5 V<br />

Output current: Approx. –100 to 0 mA<br />

DC to 50 MHz<br />

30 Arms<br />

DC to 10 MHz<br />

150 Arms<br />

DC to 2 MHz, 500 Arms<br />

Current probe<br />

701932<br />

DC to 100 MHz, 30 Arms<br />

Probe power supply<br />

701934<br />

Large current output, external probe power supply (4 outputs)<br />

50 Ω terminator<br />

Probe stand<br />

700976<br />

701919<br />

Used to connect an oscilloscope having a 1 MΩ input to an instrument having<br />

a 50 Ω output.<br />

Diameter of attachable probe : ø8 to 13mm<br />

Weight : Approx. 1.5 kg<br />