05.11.2014 Views

Measuring Instruments All Products Guide Vol.10 - Yokogawa

Measuring Instruments All Products Guide Vol.10 - Yokogawa

Measuring Instruments All Products Guide Vol.10 - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Recorders<br />

DAQMASTER<br />

Quick Start Package<br />

MX100 MW100<br />

PC-based Data Acquisition System<br />

Single Unit Data Logging<br />

Type<br />

MX100-E- /SL1<br />

High speed<br />

• 24 ch/10 ms<br />

• 60 ch/100 ms<br />

(MX110 modules connected)<br />

MX100<br />

Quick Start Package<br />

MX100-E- /SL2<br />

Simple! Compact Size! Ready to Run!<br />

Fast set up- attach sensors, connect to your network, load software, and you are ready to<br />

measure and record data<br />

• Universal inputs (DCV/TC/RTD/DI)<br />

• 100 ms scan speed<br />

• Multi-interval measurement and logging<br />

•Trending and logging software with historical viewer included<br />

Model Suffix Code Description<br />

MX100<br />

Main module<br />

Software language -E<br />

English (with MX100 standerd software)<br />

Supply voltage -1 100 VAC-240 VAC<br />

Power supply inlet and power <br />

supply cord<br />

Power supply code<br />

Options /DS Dual save function<br />

/SL1 10 ch Quick Start Package<br />

Quick Start Package<br />

/SL2 20 ch Quick Start Package<br />

/SL3 30 ch Quick Start Package<br />

Type<br />

Type<br />

MX100-E- /SL3<br />

High withstand voltage<br />

600 Vrms/VDC (continuous)<br />

3700 Vrms (1 minute)<br />

MXStandard software (comes standard with the MX100) is designed for connections to a single unit, and is ideal for small-scale data<br />

acquisition at 24 ch/10 ms or 60 ch/100 ms.<br />

The main unit is equipped with a CF card that adds to the reliability of your acquisition system by backing up data upon communication<br />

disconnections, and through the Dual recording function (optional).<br />

R&D<br />

Manufacturing<br />

facilities<br />

Equipment<br />

facilities<br />

With MXLOGGER (sold separately), you can quickly set up a large-scale data acquisition system of up to 1200 ch/20 units with no<br />

programming required.<br />

Equipped with high speed Ethernet communication (100Base-TX), enables creation of flexible measuring systems without the constraints of<br />

total cable length and connection formats.<br />

Measurement<br />

group 1<br />

Measurement<br />

group 2<br />

Measurement<br />

group 3<br />

Multi Unit Data Logging<br />

Multi Interval Data Logging<br />

Data acquisition intervals<br />

set independently by<br />

measurement group<br />

1 unit connection<br />

High reliability<br />

• Dual recording (optional)<br />

• Data backup (standard)<br />

Max. 1200 ch/system<br />

(connect 60 ch/20 units)<br />

Example<br />

1<br />

Example<br />

2<br />

Example<br />

3<br />

By assigning input modules to one of three measurement groups, you can set measuring intervals for signals from transients to temperature<br />

on a group-by-group basis.<br />

Through separate waveform observation by measurement group, you can easily find correlations in waveform changes and identify trends,<br />

improving efficiency of analysis of phenomena<br />

Web-enabled Data Acquisition and Data Logging System<br />

On-Demand, Remote <strong>Measuring</strong> System<br />

Type Sold separatelyMW100-E- /SL1<br />

Web browser monitoring<br />

& setting changes<br />

Supports Internet Explorer 5.0<br />

or later, and JAVA VM/JAVA Script<br />

Type<br />

MW100-E- /SL2<br />

Recorders<br />

46<br />

MW100<br />

Quick Start Package<br />

MW100-E- /SL3<br />

Simple! Compact Size! Ready to Run!<br />

Fast set up- attach sensors, connect to your network, confi gure with your web browser, and<br />

you are ready to measure and record data- no special software needed. Built-in data logging<br />

to high capacity Compact Flash media<br />

• Real-time data monitoring with a web browser<br />

• Universal inputs (DCV/TC/RTD/DI)<br />

• 100 ms scan speed<br />

• Multi-interval measurement and logging to high capacity CompactFlash media<br />

• Email messaging and fi le transfer via FTP<br />

Model<br />

Added<br />

Suffix Code Specifications<br />

Description<br />

Code<br />

MW100 Main module * 1, 2<br />

Language -E English (comes with MW100 Viewer Software)<br />

Supply voltage -1 100 VAC-240 VAC<br />

-2 12 to 28 VDC, with AC adapter * 3<br />

-3 12 to 28 VDC, without AC adapter * 4<br />

Power input type and power <br />

supply cord<br />

Power supply code<br />

Options /C2 RS-232 communication interface * 5, 6<br />

/C3 RS-422-A/485 communication interface * 5, 6<br />

/M1 MATH functions * 6, 7<br />

Quick Start Package<br />

/SL1<br />

/SL2<br />

/SL3<br />

*1 CF (compact flash) card not included.<br />

*2 Modbus/TCP function comes standard<br />

*3 “W” cannot be selected with “-2”<br />

*4 With -3, only W (screw terminal) can be selected<br />

10 ch Quick Start Package<br />

20 ch Quick Start Package<br />

30 ch Quick Start Package<br />

Type<br />

*5 /C2 and /C3 cannot be selected together.<br />

*6 /C2 or /C3 must be selected when using the Modbus/RTU slave function.<br />

Also, “/M1” must be selected for use of the Modbus/RTU master function.<br />

*7 /M1 must be selected when using the Modbus/TCP client function.<br />

Point a Web browser to URL of the MW100, access the MW100 at the site, and browse any data, any time.<br />

From changing settings to Starting/Stopping data acquisition, the MW100 is easy to operate with a familiar, Web browser interface.<br />

R&D<br />

Manufacturing<br />

facilities<br />

Equipment<br />

facilities<br />

Multi-User & Multi-Access<br />

Max. 60 ch/unit<br />

(widely-distributed system)<br />

Use measuring and networking technology to share a broad range of data from the field and access multiple<br />

facilities simultaneously with a Web browser to check on the status of equipment.<br />

Comes with DHCP (automatic IP address assignment) and SNTP (time correction function) for connections with<br />

Modbus-compatible instruments (requires the /M1 MATH option on the client side)<br />

Long Duration Memory & File Transmission<br />

CompactFlash:<br />

Offline<br />

CF 2 GB (60 ch/100 ms: approximately 10 days,<br />

60 ch/1 s: approximately 3 months)<br />

Drag & drop<br />

Network online (FTP: file transmission)<br />

Point a Web browser to URL of the MW100 to send MW100 data files with drag-and-drop ease<br />

Files can be sent automatically as they are created, or manually transferred with the CF card in the main unit

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!