Measuring Instruments All Products Guide Vol.10 - Yokogawa
Measuring Instruments All Products Guide Vol.10 - Yokogawa
Measuring Instruments All Products Guide Vol.10 - Yokogawa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Recorders<br />
DAQMASTER<br />
Quick Start Package<br />
MX100 MW100<br />
PC-based Data Acquisition System<br />
Single Unit Data Logging<br />
Type<br />
MX100-E- /SL1<br />
High speed<br />
• 24 ch/10 ms<br />
• 60 ch/100 ms<br />
(MX110 modules connected)<br />
MX100<br />
Quick Start Package<br />
MX100-E- /SL2<br />
Simple! Compact Size! Ready to Run!<br />
Fast set up- attach sensors, connect to your network, load software, and you are ready to<br />
measure and record data<br />
• Universal inputs (DCV/TC/RTD/DI)<br />
• 100 ms scan speed<br />
• Multi-interval measurement and logging<br />
•Trending and logging software with historical viewer included<br />
Model Suffix Code Description<br />
MX100<br />
Main module<br />
Software language -E<br />
English (with MX100 standerd software)<br />
Supply voltage -1 100 VAC-240 VAC<br />
Power supply inlet and power <br />
supply cord<br />
Power supply code<br />
Options /DS Dual save function<br />
/SL1 10 ch Quick Start Package<br />
Quick Start Package<br />
/SL2 20 ch Quick Start Package<br />
/SL3 30 ch Quick Start Package<br />
Type<br />
Type<br />
MX100-E- /SL3<br />
High withstand voltage<br />
600 Vrms/VDC (continuous)<br />
3700 Vrms (1 minute)<br />
MXStandard software (comes standard with the MX100) is designed for connections to a single unit, and is ideal for small-scale data<br />
acquisition at 24 ch/10 ms or 60 ch/100 ms.<br />
The main unit is equipped with a CF card that adds to the reliability of your acquisition system by backing up data upon communication<br />
disconnections, and through the Dual recording function (optional).<br />
R&D<br />
Manufacturing<br />
facilities<br />
Equipment<br />
facilities<br />
With MXLOGGER (sold separately), you can quickly set up a large-scale data acquisition system of up to 1200 ch/20 units with no<br />
programming required.<br />
Equipped with high speed Ethernet communication (100Base-TX), enables creation of flexible measuring systems without the constraints of<br />
total cable length and connection formats.<br />
Measurement<br />
group 1<br />
Measurement<br />
group 2<br />
Measurement<br />
group 3<br />
Multi Unit Data Logging<br />
Multi Interval Data Logging<br />
Data acquisition intervals<br />
set independently by<br />
measurement group<br />
1 unit connection<br />
High reliability<br />
• Dual recording (optional)<br />
• Data backup (standard)<br />
Max. 1200 ch/system<br />
(connect 60 ch/20 units)<br />
Example<br />
1<br />
Example<br />
2<br />
Example<br />
3<br />
By assigning input modules to one of three measurement groups, you can set measuring intervals for signals from transients to temperature<br />
on a group-by-group basis.<br />
Through separate waveform observation by measurement group, you can easily find correlations in waveform changes and identify trends,<br />
improving efficiency of analysis of phenomena<br />
Web-enabled Data Acquisition and Data Logging System<br />
On-Demand, Remote <strong>Measuring</strong> System<br />
Type Sold separatelyMW100-E- /SL1<br />
Web browser monitoring<br />
& setting changes<br />
Supports Internet Explorer 5.0<br />
or later, and JAVA VM/JAVA Script<br />
Type<br />
MW100-E- /SL2<br />
Recorders<br />
46<br />
MW100<br />
Quick Start Package<br />
MW100-E- /SL3<br />
Simple! Compact Size! Ready to Run!<br />
Fast set up- attach sensors, connect to your network, confi gure with your web browser, and<br />
you are ready to measure and record data- no special software needed. Built-in data logging<br />
to high capacity Compact Flash media<br />
• Real-time data monitoring with a web browser<br />
• Universal inputs (DCV/TC/RTD/DI)<br />
• 100 ms scan speed<br />
• Multi-interval measurement and logging to high capacity CompactFlash media<br />
• Email messaging and fi le transfer via FTP<br />
Model<br />
Added<br />
Suffix Code Specifications<br />
Description<br />
Code<br />
MW100 Main module * 1, 2<br />
Language -E English (comes with MW100 Viewer Software)<br />
Supply voltage -1 100 VAC-240 VAC<br />
-2 12 to 28 VDC, with AC adapter * 3<br />
-3 12 to 28 VDC, without AC adapter * 4<br />
Power input type and power <br />
supply cord<br />
Power supply code<br />
Options /C2 RS-232 communication interface * 5, 6<br />
/C3 RS-422-A/485 communication interface * 5, 6<br />
/M1 MATH functions * 6, 7<br />
Quick Start Package<br />
/SL1<br />
/SL2<br />
/SL3<br />
*1 CF (compact flash) card not included.<br />
*2 Modbus/TCP function comes standard<br />
*3 “W” cannot be selected with “-2”<br />
*4 With -3, only W (screw terminal) can be selected<br />
10 ch Quick Start Package<br />
20 ch Quick Start Package<br />
30 ch Quick Start Package<br />
Type<br />
*5 /C2 and /C3 cannot be selected together.<br />
*6 /C2 or /C3 must be selected when using the Modbus/RTU slave function.<br />
Also, “/M1” must be selected for use of the Modbus/RTU master function.<br />
*7 /M1 must be selected when using the Modbus/TCP client function.<br />
Point a Web browser to URL of the MW100, access the MW100 at the site, and browse any data, any time.<br />
From changing settings to Starting/Stopping data acquisition, the MW100 is easy to operate with a familiar, Web browser interface.<br />
R&D<br />
Manufacturing<br />
facilities<br />
Equipment<br />
facilities<br />
Multi-User & Multi-Access<br />
Max. 60 ch/unit<br />
(widely-distributed system)<br />
Use measuring and networking technology to share a broad range of data from the field and access multiple<br />
facilities simultaneously with a Web browser to check on the status of equipment.<br />
Comes with DHCP (automatic IP address assignment) and SNTP (time correction function) for connections with<br />
Modbus-compatible instruments (requires the /M1 MATH option on the client side)<br />
Long Duration Memory & File Transmission<br />
CompactFlash:<br />
Offline<br />
CF 2 GB (60 ch/100 ms: approximately 10 days,<br />
60 ch/1 s: approximately 3 months)<br />
Drag & drop<br />
Network online (FTP: file transmission)<br />
Point a Web browser to URL of the MW100 to send MW100 data files with drag-and-drop ease<br />
Files can be sent automatically as they are created, or manually transferred with the CF card in the main unit