Function Generators/Universal Counters<br />
Function Generators<br />
FG210/FG220/FG310/FG320/FG120/FG110<br />
http://www.yokogawa.com/tm/signalgenerator/tm-fg.htm<br />
Frequency Range 1 µHz to 15 MHz<br />
Frequency Range 1 µHz to 2 MHz<br />
Function<br />
Generators/<br />
Universal<br />
Counters<br />
FG210, FG220, FG310, FG320<br />
Synthesized Function Generators<br />
• Generating frequencies:<br />
1 µHz to 15 MHz (sine waves and square<br />
waves)<br />
1 µHz to 200 kHz (triangular, pulsed,<br />
and arbitrary)<br />
• Independent 2 channels (FG220/FG320)<br />
• Multiple sweep functions and mod u la tion<br />
functions<br />
• Intuitive operation with large LCD panel<br />
and touch screen<br />
FG200/FG300 Specifi cations<br />
• Number of signal outputs:<br />
1 (for FG210 or FG310)<br />
2 (for FG220 or FG320)<br />
• Output waveforms: sine waves<br />
Square waves (duty ratio 50% fi xed)<br />
Triangular waves (symmetry variable)<br />
Pulse waves (duty ratio variable)<br />
Arbitrary waves (FG310/FG320)<br />
• Operation mode:<br />
continuous, trigger or gate oscillation,<br />
DC output<br />
• Frequency range<br />
Sine and square waves:<br />
1 µHz to 15 MHz<br />
Triangular and pulse waves:<br />
1 µHz to 200 kHz<br />
Arbitrary waves: 1 µHz to 200 kHz<br />
• Frequency resolution:<br />
1 µHz or 9 digits max.<br />
• Max. output voltage: ±10 V<br />
(high-im ped ance load)<br />
• Output impedance: 50 Ω ± 1%<br />
• Sweep types:<br />
linear, log, linear step, log step, and<br />
arbitrary patterns (FG310/FG320)<br />
• Sweepable parameters:<br />
frequency, amplitude, offset phase, duty<br />
ra tio, frequency and amplitude<br />
• Modulation types:<br />
AM, DSB-AM, FM, phase modulation,<br />
off set modulation, or PWM<br />
• External dimensions:<br />
approx. 213 (W) × 132 (H) × 350 (D) mm<br />
•Weight: Approx. 5 kg<br />
FG120/FG110<br />
Synthesized Function Generator<br />
• Completely independent 2-channel out put<br />
(FG120)<br />
• Output waveform: sine, square, tri an gu lar,<br />
ramp and pulse<br />
• Output frequency: DC and 1 µHz to 2<br />
MHz (sine and square waves)<br />
• Max. output voltage: ±10 V<br />
• Compact (A4 size), lightweight (approx.<br />
3.6 kg) and low cost<br />
CE * : except 706011-1/-4, 706012-1/-4 models<br />
*<br />
FG120/FG110 Specifi cations<br />
• Number of signal outputs:<br />
1 (use 706011 (FG110))<br />
2 (use 706012 (FG120))<br />
• Output waveforms:<br />
sine, triangular, square wave (duty ratio<br />
50% fi xed), ramp, pulse (duty ratio 5 to<br />
95% variable)<br />
• Operation mode:<br />
continuous, trigger or gate oscillation,<br />
DC output<br />
• Output frequency range<br />
Sine and square waves:<br />
1 µHz to 2 MHz<br />
Triangular, ramp, and pulse waves:<br />
1 µHz to 100 kHz<br />
• Frequency resolution: 1 µHz or 10 digits<br />
• Max. output voltage: ±10 V*<br />
• Output impedance: 50 Ω ± 1%<br />
• GP-IB interface equipped as standard<br />
• External dimensions:<br />
approx. 213 (W) × 100 (H) × 330 (D) mm<br />
•Weight: Approx. 3.6 kg<br />
*(Maximum amplitude plus offset with highimpedance<br />
load)<br />
Universal Counters<br />
TC110/TC120<br />
http://www.yokogawa.com/tm/tc/tm-tc.htm<br />
Wide <strong>Measuring</strong> Range from 1 mHz to 2 GHz (TC120)<br />
TC110/TC120<br />
Universal Counter<br />
• <strong>Measuring</strong> frequency range:<br />
1 mHz to 2 GHz (TC120)<br />
1 mHz to 120 MHz (TC110)<br />
• Resolution of 8 digits in 1 s<br />
• Easy 1-action operation with 1 key<br />
• Convenient auto-trigger function<br />
• Measurement of revolution (TC110 only)<br />
TC110/TC120 Specifi cations<br />
• Frequencies A, B, and C<br />
Measurable range<br />
A: 1 Hz to 120 MHz (1/2-prescaler)<br />
B: 1 mHz to 60 MHz<br />
C: 100 MHz to 2 GHz (1/128-prescaler)<br />
• Period B<br />
<strong>Measuring</strong> range: 20 ns to 999.999999 s<br />
•Time interval A→B<br />
<strong>Measuring</strong> range: 60 ns to 999.999999 s<br />
• Pulse width B<br />
<strong>Measuring</strong> range: 20 ns to 999.999999 s<br />
• Duty ratio B<br />
<strong>Measuring</strong> range: 0.00000001 to<br />
0.99999999<br />
Input range: 20 ns to 999.999999 ns<br />
• Frequency ratio A/B<br />
<strong>Measuring</strong> range: A and B:<br />
1 mHz to 60 MHz<br />
•Totalization A<br />
Input frequency range: 1 mHz to 50 MHz<br />
Counting capacity: 0 to 999999999<br />
•Revolution B (TC110 only)<br />
<strong>Measuring</strong> range: 60 mrpm to 120 Mrpm<br />
• Peak voltage A and B<br />
<strong>Measuring</strong> voltage range:<br />
±5 V (ATT = x1)<br />
Frequency range: 50 Hz to 20 MHz<br />
• External dimensions:<br />
approx. 213 (W) × 100 (H) × 330 (D) mm<br />
•Weight: Approx. 3.6 kg<br />