Measuring Instruments All Products Guide Vol.10 - Yokogawa
Measuring Instruments All Products Guide Vol.10 - Yokogawa
Measuring Instruments All Products Guide Vol.10 - Yokogawa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Recorders<br />
Laboratory Recorders<br />
LR12000E/LR8100E<br />
Intelligent Pen Recorders<br />
http://www.yokogawa.com/ns/daq/daq-index_penrecorder.htm<br />
LR12000E Specifi cations<br />
LR8100E Specifi cations<br />
LR12000E<br />
Multipen Laboratory Recorder<br />
•Ten- or twelve-pen models<br />
• Universal input of voltages,<br />
thermocouples, or RTDs<br />
• Crisp, color recording and a wealth of<br />
print ing functions<br />
• High reliability owing to non-contact<br />
technologies<br />
• IC memory card (standard), fl oppy disk<br />
drive (optional)<br />
• Operating method: digital servo<br />
• Number of channels: 10 or 12<br />
• Input mode: guarded fl oating input<br />
• Measurement accuracy:<br />
0.05% of reading + 0.03% of range<br />
+ 1.0 µV<br />
(for 1 mV or more)<br />
• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />
(high sensitivity model), 12 types of<br />
thermocouples, and RTDs<br />
• Measurement cycle: 135 Hz at fastest<br />
• Chart speed: 10 to 600 mm/h or mm/min<br />
• Chart paper: effective recording width of<br />
250 mm; fan-folded, 30 m long<br />
• Recording pen: disposable felt-pen<br />
• Pen gap: about 3.5 mm, provided with<br />
phase synchronization function as standard<br />
• Printing: wire dot, ink-ribbon<br />
(monochromatic)<br />
• Display: fl uorescent display tube (5 by 7<br />
dots); 6 lines with 20 characters each<br />
• Display contents: digital values, bar graph<br />
and range<br />
• Memory: IC card slot (standard), fl oppy<br />
disk drive (optional)<br />
•Power supply: AC<br />
• Option: remote control, 12 alarm point<br />
output, communication (via GP-IB or<br />
RS-232C), fl oppy disk drive<br />
• Dimension:<br />
Approx. 438 (W) × 266 (H) × 434 (D)<br />
mm<br />
•Weight: Approx. 20 kg (for 12 pens)<br />
LR8100E<br />
Laboratory Recorder<br />
•Four-, six-, or eight-pen model<br />
• Universal input of voltages,<br />
thermocouples, or RTDs<br />
• Crisp, color recording and a wealth of<br />
print ing functions<br />
• High reliability owing to non-contact<br />
technologies<br />
• IC memory card (standard), fl oppy disk<br />
drive (optional)<br />
*<br />
• Operating method: digital servo<br />
• Number of channels: 4, 6 or 8<br />
• Input mode: guarded fl oating input<br />
• Measurement accuracy:<br />
0.05% of reading + 0.03% of range<br />
+ 1.0 µV (for 1 mV or more)<br />
• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />
(high sensitivity model), 12 types of<br />
thermocouples, and RTDs<br />
• Measurement cycle: 135 Hz at fastest<br />
• Chart speed: 10 to 1200 mm/h or mm/min<br />
• Chart paper: effective recording width of<br />
250 mm; fan-folded, 30 m long<br />
• Recording pen: disposable felt-pen<br />
• Pen gap: about 4 mm, provided with phase<br />
synchronization function as standard<br />
• Printing: wire dot, ink-ribbon<br />
(monochromatic)<br />
• Display: fl uorescent display tube (5 by 7<br />
dots); 8 lines with 20 characters each<br />
• Display contents: digital values, bar graph<br />
and range<br />
• Memory: IC card slot (standard), fl oppy<br />
disk drive (optional)<br />
•Power supply: AC or DC (optional)<br />
• Option: remote control, 8 alarm point<br />
output, communication (via GP-IB or<br />
RS-232C), fl oppy disk drive, computation,<br />
10 to 32 V DC drive<br />
• Dimension:<br />
Approx. 438 (W) × 266 (H) × 310 (D)<br />
mm<br />
•Weight: Approx. 16 kg (for 8 pens)<br />
CE * : Except the -/B model<br />
Laboratory Recorders<br />
LR4100E/LR4200E<br />
Intelligent Pen Recorders<br />
http://www.yokogawa.com/ns/daq/daq-index_penrecorder.htm<br />
Recorders<br />
LR4100E<br />
Laboratory Recorder<br />
• One-, two-, three-, or four-pen model<br />
• Universal input of voltages,<br />
thermocouples, or RTDs<br />
• Crisp, color recording and a wealth of<br />
print ing functions<br />
• High reliability owing to non-contact<br />
technologies<br />
• IC memory card (standard), fl oppy disk<br />
drive (optional)<br />
CE * : Except the -/B model<br />
LR4100E Specifi cations<br />
• Operating method: digital servo<br />
• Number of channels: 1, 2, 3, or 4<br />
• Input mode: guarded fl oating input<br />
• Measurement accuracy:<br />
0.05% of reading + 0.03% of range<br />
+ 1.0 µV(for 1 mV or more voltage<br />
range)<br />
• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />
(high sensitivity model), 12 types of<br />
thermocouples, and RTDs<br />
• Measurement cycle: 135 Hz at fastest<br />
• Chart speed: 10 to 1200 mm/h or mm/min<br />
• Chart paper: effective recording width of<br />
250 mm; fan-folded, 20 m long<br />
• Recording pen: disposable felt-pen<br />
• Pen gap: about 4 mm, provided with phase<br />
synchronization function as standard<br />
• Printing: wire dot, ink-ribbon<br />
(monochromatic)<br />
• Display: fl uorescent display tube (5 by 7<br />
dots); 4 lines with 20 characters each<br />
• Display contents: digital values, bar graph<br />
and range<br />
• Memory: IC card slot (standard), fl oppy<br />
disk drive (optional)<br />
•Power supply: AC or DC (optional)<br />
• Option: remote control, 4 alarm point<br />
output, communication (via GP-IB or<br />
RS-232C), fl oppy disk drive, computation,<br />
10 to 32 V DC drive<br />
• Dimension:<br />
Approx. 438 (W) × 199 (H) × 323 (D)<br />
mm<br />
•Weight: Approx. 14 kg (for 4 pens)<br />
* *<br />
LR4200E<br />
Flat-Bed Laboratory Recorder<br />
• One-, two-, three-, or four-pen model<br />
• Universal input of voltages,<br />
thermocouples, or RTDs<br />
• Crisp, color recording and a wealth of<br />
print ing functions<br />
• High reliability owing to non-contact<br />
technologies<br />
• IC memory card (standard)<br />
CE * : Except the -/B model<br />
LR4200E Specifi cations<br />
• Operating method: digital servo<br />
• Number of channels: 1, 2, 3, or 4<br />
• Input mode: guarded fl oating input<br />
• Measurement accuracy:<br />
0.05% of reading + 0.03% of range<br />
+ 1.0 µV (for 1 mV or more)<br />
• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />
(high sensitivity model), 12 types of<br />
thermocouples, and RTDs<br />
• Measurement cycle: 135 Hz at fastest<br />
• Chart speed: 10 to 1200 mm/h or mm/min<br />
• Chart paper: effective recording width of<br />
250 mm; fan-folded, 20 m long<br />
• Recording pen: disposable felt-pen<br />
• Pen gap: about 4 mm, provided with phase<br />
synchronization function as standard<br />
• Printing: wire dot, ink-ribbon<br />
(monochromatic)<br />
• Display: fl uorescent display tube (5 by 7<br />
dots); 4 lines with 20 characters each<br />
• Display contents: digital values, bar graph<br />
and range<br />
• Memory: IC card slot (standard)<br />
•Power supply: AC<br />
• Option: remote control, 4 alarm point<br />
output, communication (via GP-IB or<br />
RS-232C), computation, roll chart, re-roll<br />
func tion<br />
• Dimension:<br />
Approx. 448 (W) × 455 (D) × 185 (H)<br />
mm<br />
•Weight: Approx. 14 kg (with 4 pens)<br />