Recorders<br />

Laboratory Recorders<br />

LR12000E/LR8100E<br />

Intelligent Pen Recorders<br />

http://www.yokogawa.com/ns/daq/daq-index_penrecorder.htm<br />

LR12000E Specifi cations<br />

LR8100E Specifi cations<br />

LR12000E<br />

Multipen Laboratory Recorder<br />

•Ten- or twelve-pen models<br />

• Universal input of voltages,<br />

thermocouples, or RTDs<br />

• Crisp, color recording and a wealth of<br />

print ing functions<br />

• High reliability owing to non-contact<br />

technologies<br />

• IC memory card (standard), fl oppy disk<br />

drive (optional)<br />

• Operating method: digital servo<br />

• Number of channels: 10 or 12<br />

• Input mode: guarded fl oating input<br />

• Measurement accuracy:<br />

0.05% of reading + 0.03% of range<br />

+ 1.0 µV<br />

(for 1 mV or more)<br />

• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />

(high sensitivity model), 12 types of<br />

thermocouples, and RTDs<br />

• Measurement cycle: 135 Hz at fastest<br />

• Chart speed: 10 to 600 mm/h or mm/min<br />

• Chart paper: effective recording width of<br />

250 mm; fan-folded, 30 m long<br />

• Recording pen: disposable felt-pen<br />

• Pen gap: about 3.5 mm, provided with<br />

phase synchronization function as standard<br />

• Printing: wire dot, ink-ribbon<br />

(monochromatic)<br />

• Display: fl uorescent display tube (5 by 7<br />

dots); 6 lines with 20 characters each<br />

• Display contents: digital values, bar graph<br />

and range<br />

• Memory: IC card slot (standard), fl oppy<br />

disk drive (optional)<br />

•Power supply: AC<br />

• Option: remote control, 12 alarm point<br />

output, communication (via GP-IB or<br />

RS-232C), fl oppy disk drive<br />

• Dimension:<br />

Approx. 438 (W) × 266 (H) × 434 (D)<br />

mm<br />

•Weight: Approx. 20 kg (for 12 pens)<br />

LR8100E<br />

Laboratory Recorder<br />

•Four-, six-, or eight-pen model<br />

• Universal input of voltages,<br />

thermocouples, or RTDs<br />

• Crisp, color recording and a wealth of<br />

print ing functions<br />

• High reliability owing to non-contact<br />

technologies<br />

• IC memory card (standard), fl oppy disk<br />

drive (optional)<br />

*<br />

• Operating method: digital servo<br />

• Number of channels: 4, 6 or 8<br />

• Input mode: guarded fl oating input<br />

• Measurement accuracy:<br />

0.05% of reading + 0.03% of range<br />

+ 1.0 µV (for 1 mV or more)<br />

• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />

(high sensitivity model), 12 types of<br />

thermocouples, and RTDs<br />

• Measurement cycle: 135 Hz at fastest<br />

• Chart speed: 10 to 1200 mm/h or mm/min<br />

• Chart paper: effective recording width of<br />

250 mm; fan-folded, 30 m long<br />

• Recording pen: disposable felt-pen<br />

• Pen gap: about 4 mm, provided with phase<br />

synchronization function as standard<br />

• Printing: wire dot, ink-ribbon<br />

(monochromatic)<br />

• Display: fl uorescent display tube (5 by 7<br />

dots); 8 lines with 20 characters each<br />

• Display contents: digital values, bar graph<br />

and range<br />

• Memory: IC card slot (standard), fl oppy<br />

disk drive (optional)<br />

•Power supply: AC or DC (optional)<br />

• Option: remote control, 8 alarm point<br />

output, communication (via GP-IB or<br />

RS-232C), fl oppy disk drive, computation,<br />

10 to 32 V DC drive<br />

• Dimension:<br />

Approx. 438 (W) × 266 (H) × 310 (D)<br />

mm<br />

•Weight: Approx. 16 kg (for 8 pens)<br />

CE * : Except the -/B model<br />

Laboratory Recorders<br />

LR4100E/LR4200E<br />

Intelligent Pen Recorders<br />

http://www.yokogawa.com/ns/daq/daq-index_penrecorder.htm<br />

Recorders<br />

LR4100E<br />

Laboratory Recorder<br />

• One-, two-, three-, or four-pen model<br />

• Universal input of voltages,<br />

thermocouples, or RTDs<br />

• Crisp, color recording and a wealth of<br />

print ing functions<br />

• High reliability owing to non-contact<br />

technologies<br />

• IC memory card (standard), fl oppy disk<br />

drive (optional)<br />

CE * : Except the -/B model<br />

LR4100E Specifi cations<br />

• Operating method: digital servo<br />

• Number of channels: 1, 2, 3, or 4<br />

• Input mode: guarded fl oating input<br />

• Measurement accuracy:<br />

0.05% of reading + 0.03% of range<br />

+ 1.0 µV(for 1 mV or more voltage<br />

range)<br />

• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />

(high sensitivity model), 12 types of<br />

thermocouples, and RTDs<br />

• Measurement cycle: 135 Hz at fastest<br />

• Chart speed: 10 to 1200 mm/h or mm/min<br />

• Chart paper: effective recording width of<br />

250 mm; fan-folded, 20 m long<br />

• Recording pen: disposable felt-pen<br />

• Pen gap: about 4 mm, provided with phase<br />

synchronization function as standard<br />

• Printing: wire dot, ink-ribbon<br />

(monochromatic)<br />

• Display: fl uorescent display tube (5 by 7<br />

dots); 4 lines with 20 characters each<br />

• Display contents: digital values, bar graph<br />

and range<br />

• Memory: IC card slot (standard), fl oppy<br />

disk drive (optional)<br />

•Power supply: AC or DC (optional)<br />

• Option: remote control, 4 alarm point<br />

output, communication (via GP-IB or<br />

RS-232C), fl oppy disk drive, computation,<br />

10 to 32 V DC drive<br />

• Dimension:<br />

Approx. 438 (W) × 199 (H) × 323 (D)<br />

mm<br />

•Weight: Approx. 14 kg (for 4 pens)<br />

* *<br />

LR4200E<br />

Flat-Bed Laboratory Recorder<br />

• One-, two-, three-, or four-pen model<br />

• Universal input of voltages,<br />

thermocouples, or RTDs<br />

• Crisp, color recording and a wealth of<br />

print ing functions<br />

• High reliability owing to non-contact<br />

technologies<br />

• IC memory card (standard)<br />

CE * : Except the -/B model<br />

LR4200E Specifi cations<br />

• Operating method: digital servo<br />

• Number of channels: 1, 2, 3, or 4<br />

• Input mode: guarded fl oating input<br />

• Measurement accuracy:<br />

0.05% of reading + 0.03% of range<br />

+ 1.0 µV (for 1 mV or more)<br />

• <strong>Measuring</strong> range: 0.1 mV to 200 V FS<br />

(high sensitivity model), 12 types of<br />

thermocouples, and RTDs<br />

• Measurement cycle: 135 Hz at fastest<br />

• Chart speed: 10 to 1200 mm/h or mm/min<br />

• Chart paper: effective recording width of<br />

250 mm; fan-folded, 20 m long<br />

• Recording pen: disposable felt-pen<br />

• Pen gap: about 4 mm, provided with phase<br />

synchronization function as standard<br />

• Printing: wire dot, ink-ribbon<br />

(monochromatic)<br />

• Display: fl uorescent display tube (5 by 7<br />

dots); 4 lines with 20 characters each<br />

• Display contents: digital values, bar graph<br />

and range<br />

• Memory: IC card slot (standard)<br />

•Power supply: AC<br />

• Option: remote control, 4 alarm point<br />

output, communication (via GP-IB or<br />

RS-232C), computation, roll chart, re-roll<br />

func tion<br />

• Dimension:<br />

Approx. 448 (W) × 455 (D) × 185 (H)<br />

mm<br />

•Weight: Approx. 14 kg (with 4 pens)<br />