Page 12<br />
4.1.d Electrical Cutouts<br />
WS03, WS05 and SP05<br />
BOTTOM<br />
1-3/8 in [3.5 cm]<br />
7/8 in [2.2 cm]<br />
Figure 10<br />
WS10<br />
BOTTOM<br />
1-3/8 in<br />
[3.5 cm]<br />
Figure 11<br />
4.2 Placing Heat Pump<br />
4.2.a Positioning Clearances<br />
<br />
<br />
<br />
Confirm adequate clearance is provided above and around heat pump to permit access panel<br />
removal during equipment maintenance and service. Do not place objects such as shrubs, bushes,<br />
lawn furniture, chemical containers, etc. immediately adjacent or on top of heat pump. These items<br />
can prevent access and may result in damage to the heat pump.<br />
The unit should be located at least 18 inches from any wall and at least 18 inches between units to<br />
permit rear plumbing and electrical connections.<br />
Follow all applicable local, state, and national requirements relative to spacing from other objects or<br />
equipment.