Page 34<br />

FAULT CODE RULE OUT RESOLUTION<br />

Water Pressure<br />

Switch<br />

incorrectly<br />

calibrated<br />

STEP 3:<br />

See section entitled “Water Flow (Pressure) Switch<br />

Adjustment” on page 20.<br />

STEP 4:<br />

Call heat pump installer or <strong>AquaCal</strong> AutoPilot<br />

Customer Support for further assistance.<br />

“CSE” Indicator<br />

Control system error.<br />

“CEr” Indicator<br />

Communication fault.<br />

Defective control<br />

board<br />

Loose or<br />

damaged cable<br />

STEP 1:<br />

Disconnect then reconnect power to reset control. If<br />

error recurs, proceed to next step.<br />

STEP 2:<br />

Control board requires replacement. If error recurs,<br />

proceed to next step.<br />

STEP 3:<br />

Call heat pump installer or <strong>AquaCal</strong> AutoPilot<br />

Customer Support for further assistance.<br />

STEP 1:<br />

Check “Cat5” cable from control board to display<br />

assembly.<br />

STEP 2:<br />

Call heat pump installer or <strong>AquaCal</strong> AutoPilot<br />

Customer Support for further assistance.<br />

Table 14