SECTION 5 - TROUBLESHOOTING<br />
5.1 Symptom / Resolution Charts<br />
WARNING<br />
WARNING<br />
- Failure to heed the following may result in injury or death.<br />
Repairs must not be attempted by untrained unqualified individuals. If service is<br />
deemed necessary, contact installing dealer or <strong>AquaCal</strong> AutoPilot Customer<br />
Support.<br />
- Failure to heed the following may result in injury or death.<br />
Heat pump contains refrigerant under high pressure. Repairs to refrigerant circuit<br />
must not be attempted by untrained or unqualified individuals. Service must be<br />
performed only by qualified HVAC technicians. Recover refrigerant before opening<br />
system.<br />
CAUTION<br />
- Failure to heed the following may result in equipment damage.<br />
Service by un-authorized personnel will void factory warranty.<br />
Please note – Troubleshooting charts are for Main Controller version 3.0.<br />
SYMPTOM RULE OUT RESOLUTION<br />
Control Panel Not Working<br />
An external<br />
controller is<br />
being used<br />
STEP 1:<br />
See section entitled “Configuring for External Controller”<br />
on page 24 for more information on heat pump<br />
controller functionality when using external controllers.<br />
STEP 2:<br />
Call heat pump installer or <strong>AquaCal</strong> AutoPilot Customer<br />
Support for further assistance.<br />
Heat Pump Not Running<br />
No power to heat<br />
pump<br />
Incorrect mode<br />
setting<br />
Thermostat set<br />
incorrectly<br />
Error displayed<br />
STEP 1:<br />
Confirm heat pump display is illuminated.<br />
If not, confirm the main breaker (located at the<br />
power supply panel) and the disconnect switch<br />
(located near the heat pump) are both turned ON.<br />
If yes, proceed to next step.<br />
STEP 2:<br />
Confirm correct mode is selected. See “Setting<br />
Operating Mode” on page 3. If heat pump still does not<br />
turn on, proceed to next step.<br />
STEP 3:<br />
Confirm that thermostat is set above / below current<br />
water temperature depending on mode setting. See<br />
“Setting Thermostats” on page 3. If heat pump still does<br />
not turn on, proceed to next step.<br />
STEP 5:<br />
If an error code is displayed, see appropriate fault code<br />
in this section. If no fault code is displayed, proceed to<br />
next step.