SAFETY WARNING:<br />

THE INSTALLER IS RESPONSIBLE FOR PROPER<br />

INSTALLA<br />

ALLATION.<br />

THESE FIXTURES MUST BE INSTALLED BY A<br />

QUALIFIED PERSON IN ACCORD<br />

CCORDANCE<br />

WITH<br />

NATIONAL ELECTRIC CODE AND RELEVANT<br />

LOCAL CODES.<br />

READ 1990 NATIONAL ELECTRIC CODE<br />

ARTICLE 680-20 THRU 680-22 PRIOR TO<br />

INSTALLING.<br />

ATTACH WIRE TIES TO MOUNTING<br />

EARS AND SECURE TO RE-BAR<br />

<strong>NICHE</strong><br />

1. INSTALL <strong>NICHE</strong> IN PLACE AND SECURE<br />

TO RE-BAR BY WIRING TO EARS ON<br />

<strong>NICHE</strong>.<br />

2. MAKE SURE <strong>NICHE</strong> FLANGE WILL BE<br />

COMPLETELY COVERED IN PLASTER<br />

FOR A WATER-TIGHT SEAL. BE SURE<br />

THE <strong>NICHE</strong> IS LEVEL.<br />

3. ATT<br />

TTACH<br />

THE CONDUIT TO THE <strong>NICHE</strong><br />

HOUSING.<br />

NOTE:<br />

THE CONDUIT HUB MUST BE ORIENTED AT<br />

THE TOP. WHEN LOW VOLTAGE FIXTURES<br />

OR PLASTIC CONDUIT IS USED IT IS<br />

RECONNENDED THAT 1" CONDUIT<br />

BE USED.<br />

4. IF PLASTIC CONDUIT IS USED, A #8<br />

STRANDED COPPER BOND WIRE MUST<br />

BE POSITIVELY ATT<br />

TTACHED IN THE<br />

JUNCTION BOX,<br />

PULLED THROUGH<br />

THE CONDUIT, AND SECURED TO THE<br />

BONDING LUG INSIDE THE <strong>NICHE</strong>.<br />

5. TO O MEET NATIONAL ELECTRIC CODE<br />

REQUIREMENTS:<br />

"THE TERMINATION<br />

TION<br />

OF THE #8 CONDUCTOR OR IN THE FORM<br />

ING SHELL SHALL BE COVERED<br />

WITH,<br />

OR ENCAPSULATED IN, A LISTED<br />

POTTING COMPOUND TO O PROTECT<br />

SUCH CONNECTION FROM<br />

THE POS<br />

SIBLE DETERIORATING TING EFFECT OF<br />

POOL WATER."<br />

6. COVER <strong>NICHE</strong>, SHOOT T GUNITE, AND<br />

PRIME TRIM PLASTER TO FLANGE<br />

EDGE.<br />

7. INSTALL FIXTURE.<br />

POOL FINISH SURFACE (PLASTER)<br />

MUST BE CUT BACK BEHIND THE<br />

STAINLESS STEEL <strong>NICHE</strong>-CAN<br />

FLANGES, FOR A WATERTIGHT SEAL.<br />

POOL FINISH SURFACE (PLASTER)<br />

MUST BE CUT BACK BEHIND THE<br />

STAINLESS STEEL <strong>NICHE</strong>-CAN<br />

FLANGES, FOR A WATERTIGHT SEAL.<br />

Swimming pools 18" min. per NEC.<br />

Recommend 2" for Fountain<br />

WATER<br />

#8 BONDING WIRE<br />

(FOR PVC CONDUIT USES ONLY)<br />

LIGHT<br />

POOL FINISH SURFACE (PLASTER)<br />

MUST BE CUT BACK BEHIND THE<br />

STAINLESS STEEL <strong>NICHE</strong>-CAN<br />

FLANGES, FOR A WATERTIGHT SEAL.<br />

<strong>NICHE</strong><br />

<strong>NICHE</strong><br />

HYDREL is a registered trademark of Lithonia Lighting<br />

12881 BRADLEY AVENUE, SYLMAR, CALIFORNIA 91342 • PHONE: 818/362-9465 • FAX: 818/362-6548<br />

HYDREL INS'S\INS-UWL-3 10/99


<strong>4400</strong> & <strong>4800</strong> <strong>SERIES</strong> <strong>WET</strong> <strong>NICHE</strong><br />

<strong>INSTALLATION</strong> <strong>INSTRUCTIONS</strong><br />

JUNCTION BOX<br />

CONDUIT<br />

Hydrel fixtures are designed to meet 1990 National Electric Code, Article<br />

680 requirements. The N.E.C. requires that fixtures must be installed so<br />

that the fixture lens is at least 18" below normal water level. The junction<br />

box shall be located at least 8" above maximum water level, pool deck or<br />

ground, whichever is greater. The junction box shall be located not less<br />

than 4 feet from the perimeter of the pool, unless separated from the pool<br />

by a fence, wall or other permanent barrier. Junction boxes mounted<br />

above grade in the walkway around the pool shall be afforded additional<br />

protection by locating them in such places as under a diving board,<br />

adjacent to fixed structures, etc. Check local codes to assure acceptance.<br />

<strong>4400</strong> <strong>SERIES</strong><br />

TWIST AND LOCK MOUNTING<br />

<strong>4800</strong> <strong>SERIES</strong><br />

CONCRETE <strong>NICHE</strong>S, EXTENDED<br />

#8 STRANDED<br />

EQUIP. GROUND<br />

BONDING<br />

Mounting the fixture into the niche is simple and positive with the Twist and<br />

Lock feature. Fixture may be inserted directly into the niche. (No hooking a<br />

lower lug or slipping over a pin.) Fixture is inserted and given a slight<br />

clockwise twist. The retaining screw then provides a positive fixture lock.<br />

NOTE: Screw should be located at top of fixture.<br />

SOLID<br />

WIRE<br />

JUNCTION BOX AND FIXTURE <strong>INSTALLATION</strong> <strong>NICHE</strong> MOUNT<br />

(FOUNTAINS ONLY)<br />

TILE OR CONCRETE<br />

FOUNTAIN FLOOR<br />

FIXTURE<br />

JUNCTION BOX<br />

PC-21<br />

POTTING COMPOUND<br />

PER NEC680<br />

USR<br />

STRAIN RELIEF<br />

<strong>NICHE</strong><br />

EXCESS<br />

CORD COILED<br />

SO LAMP CAN<br />

BE REMOVED<br />

1" SERVOCE<br />

ENTRANCE<br />

CONDUIT<br />

HYDREL is a registered trademark of Lithonia Lighting<br />

#8 SOLID COPPER<br />

BOND WIRE<br />

CORD<br />

CONDUIT<br />

(3-90° BENDS MAX.)<br />

12881 BRADLEY AVENUE, SYLMAR, CALIFORNIA 91342 • PHONE: 818/362-9465 • FAX: 818/362-6548<br />

HYDREL INS'S\INS-UWL-3 10/99

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!