- Specify DRR image enhancement tools to improve DRR image quality Reconstruction<br />

of DRRs should be real- time or sub-second Direct printing of DRR on laser film should<br />

be possible.<br />

- Real-time displays of DRR as beam parameters are changed.<br />

- It should be possible to transfer DRR and BEV images to EPID of Linear Accerlator.<br />

- Depth Control in oblique projections must be possible<br />

- Cross-hair display on DRR to provide scale information.<br />

SUPPORT OF ASSYMMETRIC COLLIMATORS AND MULTILEAF COLLIMATORS<br />

(MLCs):<br />

- It should be possible to define this asymmetric collimator feature, where both the X-<br />

and Y-pairs of jaws are asymmetric. The software should allow multi-leaf collimator<br />

placement up to 60 pairs or more.<br />

Isocenter management:- The software should support separate isocenters for multiple target<br />

volumes or general regions.<br />

- Marked and final isocenters should be reported and displayed in the Localization<br />

package for easy confirmation of a physical simulation session.<br />

- Hardcopy of the isocenter coordinates should be possible for record of the simulation<br />

session.<br />

- No limit on number of isocenters per target.<br />

VOLUME RENDERING<br />

- 3D view and volume rendering capabilities<br />

- Post processing features like Volume Rendering, Real-time multi-axial volume<br />

reconstruction, - 3D surface rendering, Color 3D should be available.<br />

- It should allow complete 3D volume to be defined including complex 3D volumes, user<br />

selectable multi-images views, Beams Eye View, DRR etc.<br />

Data Import / Export<br />

- System should be able to export Image, volume and plan data in DICOM 3.0 standard<br />

along with all Radiotherapy specific data and private objects, DICOM RT plans and<br />

data sets.<br />

- System should be able to import DICOM RT data.<br />

- Dose Module should consist of two different types of calculation algorithm namely<br />

Collapsed Cone Convolution algorithm for photon beam dose calculation<br />

- Pencil Beam algorithm for Photon beam dose calculation<br />

- It should be possible to define the absolute dose to a specified point for each beam or<br />

MUs or time (isotope base machines).<br />