- Specify DRR image enhancement tools to improve DRR image quality Reconstruction<br />
of DRRs should be real- time or sub-second Direct printing of DRR on laser film should<br />
be possible.<br />
- Real-time displays of DRR as beam parameters are changed.<br />
- It should be possible to transfer DRR and BEV images to EPID of Linear Accerlator.<br />
- Depth Control in oblique projections must be possible<br />
- Cross-hair display on DRR to provide scale information.<br />
SUPPORT OF ASSYMMETRIC COLLIMATORS AND MULTILEAF COLLIMATORS<br />
(MLCs):<br />
- It should be possible to define this asymmetric collimator feature, where both the X-<br />
and Y-pairs of jaws are asymmetric. The software should allow multi-leaf collimator<br />
placement up to 60 pairs or more.<br />
Isocenter management:- The software should support separate isocenters for multiple target<br />
volumes or general regions.<br />
- Marked and final isocenters should be reported and displayed in the Localization<br />
package for easy confirmation of a physical simulation session.<br />
- Hardcopy of the isocenter coordinates should be possible for record of the simulation<br />
session.<br />
- No limit on number of isocenters per target.<br />
VOLUME RENDERING<br />
- 3D view and volume rendering capabilities<br />
- Post processing features like Volume Rendering, Real-time multi-axial volume<br />
reconstruction, - 3D surface rendering, Color 3D should be available.<br />
- It should allow complete 3D volume to be defined including complex 3D volumes, user<br />
selectable multi-images views, Beams Eye View, DRR etc.<br />
Data Import / Export<br />
- System should be able to export Image, volume and plan data in DICOM 3.0 standard<br />
along with all Radiotherapy specific data and private objects, DICOM RT plans and<br />
data sets.<br />
- System should be able to import DICOM RT data.<br />
- Dose Module should consist of two different types of calculation algorithm namely<br />
Collapsed Cone Convolution algorithm for photon beam dose calculation<br />
- Pencil Beam algorithm for Photon beam dose calculation<br />
- It should be possible to define the absolute dose to a specified point for each beam or<br />
MUs or time (isotope base machines).<br />