Vektor-CD Performance Catalog - Greenheck
Vektor-CD Performance Catalog - Greenheck
Vektor-CD Performance Catalog - Greenheck
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
AIR DATA<br />
LV<br />
Low Velocity<br />
<strong>Vektor</strong>-<strong>CD</strong> Size 18<br />
VEKTOR<strong>CD</strong>-18LV<br />
Inlet Airflow<br />
Static Pressure (Pa x 100)<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
Static Pressure (in. wg)<br />
RPM<br />
HP<br />
WOV<br />
Density 0.075<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
870<br />
1450<br />
1770<br />
MAX RESISTANCE CURVE<br />
950<br />
1170 1<br />
/3 hp<br />
2000<br />
¾ hp<br />
2300<br />
1½ hp<br />
2700<br />
3001<br />
3 hp<br />
3300<br />
50% WOV<br />
3600<br />
5 hp<br />
Volume (cfm x 1000)<br />
VEKTOR<strong>CD</strong>-18MV Volume (m 3 /hr x 1000)<br />
50 Cycle RPM<br />
60 Cycle RPM<br />
0<br />
0 1 2 3 4 5 6 7 8 9 10 11 12<br />
0 2 4 6 8 10 12 14 16 18 20<br />
3781<br />
7½ hp<br />
60% WOV<br />
10 hp<br />
15 hp<br />
70% WOV<br />
20 hp<br />
25 hp<br />
80% WOV<br />
90% WOV<br />
Static Pressure (Pa x 100)<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
Static Pressure (in. wg)<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
Outlet Airflow<br />
<strong>Vektor</strong>-<strong>CD</strong> 18-LV<br />
1770<br />
DO NOT SELDCT TO THE LEFT OF THIS SYSTEM CURVE<br />
3001<br />
0<br />
0 2 4 6 8 10 12 14 16<br />
Volume (cfm x 1000)<br />
0 2 4 6 8 10 12 14 16 18 20 22 24 26<br />
Volume (m 3 /hr x 1000)<br />
Note: When selecting a fan size please use the fan inlet airflow curve only ( )<br />
<strong>Vektor</strong>-<strong>CD</strong> 18-MV<br />
3781<br />
rpm - Fan Inlet Airflow<br />
rpm - Windband Outlet Airflow<br />
Density 0.075 lb/ft<br />
MV<br />
Medium Velocity<br />
Static Pressure (Pa x 100)<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
Static Pressure (in. wg)<br />
RPM<br />
HP<br />
WOV<br />
Density 0.075<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
870<br />
1450<br />
1170<br />
950<br />
1<br />
/3 hp<br />
1770<br />
2000<br />
MAX RESISTANCE CURVE<br />
¾ hp<br />
2300<br />
1½ hp<br />
2700<br />
3001<br />
3 hp<br />
3300<br />
50% WOV<br />
3600<br />
5 hp<br />
3781<br />
Volume (cfm x 1000)<br />
Volume (m 3 /hr x 1000)<br />
VEKTOR<strong>CD</strong>-18HV<br />
50 Cycle RPM<br />
60 Cycle RPM<br />
0<br />
0 1 2 3 4 5 6 7 8 9 10 11 12<br />
0 2 4 6 8 10 12 14 16 18 20<br />
7½ hp<br />
60% WOV<br />
10 hp<br />
15 hp<br />
70% WOV<br />
20 hp<br />
25 hp<br />
80% WOV<br />
90% WOV<br />
Static Pressure (Pa x 100)<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
Static Pressure (in. wg)<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
1770<br />
DO NOT SELECT TO THE LEFT OF THIS SYSTEM CURVE<br />
3001<br />
3781<br />
rpm - Fan Inlet Airflow<br />
rpm - Windband Outlet Airflow<br />
Density 0.075 lb/ft<br />
0<br />
0 2 4 6 8 10 12 14 16 18<br />
Volume (cfm x 1000)<br />
0 5 10 15 20 25 30<br />
Volume (m 3 /hr x 1000)<br />
Note: When selecting a fan size please use the fan inlet airflow curve only ( )<br />
<strong>Vektor</strong>-<strong>CD</strong> 18-HV<br />
HV<br />
High Velocity<br />
Static Pressure (Pa x 100)<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
Static Pressure (in. wg)<br />
RPM<br />
HP<br />
WOV<br />
Density 0.075<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
870<br />
1450<br />
1170<br />
1770<br />
2000<br />
2300<br />
1½ hp<br />
MAX RESISTANCE CURVE<br />
950<br />
1<br />
/3 hp<br />
¾ hp<br />
2700<br />
3000<br />
3 hp<br />
3300<br />
3600<br />
5 hp<br />
50% WOV<br />
3781<br />
Volume (cfm x 1000)<br />
60% WOV<br />
70% WOV<br />
50 Cycle RPM<br />
60 Cycle RPM<br />
80% WOV<br />
90% WOV<br />
0<br />
0 1 2 3 4 5 6 7 8 9 10 11<br />
0 2 4 6 8 10 12 14 16 18<br />
Volume (m 3 /hr x 1000)<br />
7½ hp<br />
10 hp<br />
15 hp<br />
20 hp<br />
25 hp<br />
Static Pressure (Pa x 100)<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
0<br />
Static Pressure (in. wg)<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
1770<br />
DO NOT SELECT TO THE LEFT OF THIS SYSTEM CURVE<br />
3001<br />
3781<br />
0<br />
0 2 4 6 8 10 12 14 16 18<br />
Volume (cfm x 1000)<br />
0 5 10 15 20 25 30<br />
Volume (m 3 /hr x 1000)<br />
Note: When selecting a fan size please use the fan inlet airflow curve only ( )<br />
rpm - Fan Inlet Airflow<br />
rpm - Windband Outlet Airflow<br />
Density 0.075 lb/ft<br />
18<br />
<strong>Performance</strong> certified is for installation Type A: Free inlet, Free outlet.<br />
<strong>Performance</strong> ratings do not include the effects of appurtenances<br />
(accessories). Power ratings (Bhp) do not include transmission losses.<br />
<strong>Performance</strong> ratings do not include the effects of cross winds.<br />
<strong>Performance</strong> certified is for installation Type A: Free inlet, Free outlet.<br />
<strong>Performance</strong> ratings do not include the effects of appurtenances<br />
(accessories). <strong>Performance</strong> ratings do not include the effects of cross winds.<br />
The AMCA Certified Ratings Seal applies to induced flow fan air<br />
performance and sound (AMCA Standard 260).