BATTERY<br />
The generator’s engine has a 0.5 amp charging system to charge the<br />
battery while the engine is running. If the generator is only used<br />
periodically, the battery must be charged monthly to maintain the<br />
battery service life.<br />
A lead acid battery self discharges at a rate of 0.51.0% per day. This<br />
means that the battery, if the generator is not operated in a month,<br />
can discharge as much as 30% in the same period. This could cause<br />
the engine not to crank or shorten the service life of the battery. To<br />
charge the battery, follow the procedures below.<br />
Removal:<br />
WARNING: Battery posts, terminals and related accessories contain<br />
lead and lead compounds. Wash hands after handling.<br />
1. Remove the four 6 mm<br />
cap nuts, and remove the<br />
front cover.<br />
FRONT COVER<br />
6 mm CAP NUTS<br />
2. Remove the battery holder band.<br />
3. Remove the negative ( ) cable from the battery negative ( )<br />
terminal; then remove the positive ( ) cable from the battery<br />
positive ( ) terminal.<br />
NEGATIVE ( ) CABLE<br />
POSITIVE ( ) CABLE<br />
BATTERY HOLDER BAND<br />
4. Remove the battery from the battery tray.<br />