SECTION 14<br />

ACCEPTANCE TEST PROCEDURES (cont)<br />

14.3.8.8 <strong>Co</strong>ntrol Rod Drive<br />

14.3.8.8.1 Stuck Rod (Trippable)<br />

14.3.8.8.2 Dropped Rod (Stationary Gripper)<br />

14.3.8.8.3 IRPI Blown Fuse<br />

14.3.8.9 Chemical and Volume <strong>Co</strong>ntrol<br />

14.3.8.9.1 Charging Pump Suction Header Leak<br />

14.3.8.9.2 Charging Line Leak Inside <strong>Co</strong>ntainment<br />

14.3.8.9.3 Volume <strong>Co</strong>ntrol Tank Leak<br />

14.3.8.9.4 Boric Acid Filter Plugs<br />

14.3.8.9.5 RCP #1 Seal Failure<br />

14.3.8.9.6 RCP #2 Seal Failure<br />

14.3.8.9.7 Spurious Opening of MOV-333<br />

14.3.8.9.8 Charging Pump Speed <strong>Co</strong>ntroller Failure<br />

14.3.8.9.9 Charging Pump Reduced Capacity<br />

14.3.8.10 Circulating Water<br />

14.3.8.10.1 <strong>Co</strong>ndenser Tube Leak<br />

14.3.8.11 Diesel Generator<br />

None<br />

14.3.8.12 Turbine <strong>Co</strong>ntrol<br />

14.3.8.12.1 Turbine Trip Failure<br />

14.3.8.13 Electrical Distribution<br />

14.3.8.13.1 Loss of Station Service Transformer<br />

14.3.8.13.2 Loss of Unit Aux Transformer<br />

14.3.8.14 Fire Protection<br />

14.3.8.14.1 <strong>Plant</strong> Fire<br />

14.3.8.15 Feedwater Heaters, Extractions, Drains, and Vents<br />

14.3.8.15.1 Feedwater Heater Tube Leak (HP)<br />

14.3.8.15.2 Feedwater Heater Tube Leak (LP)<br />

14.3.8.16 Main Generator<br />

14.3.8.16.1 Loss of Main Transformer<br />

14.3.8.16.2 Generator Trip Failure<br />

14.3.8.17 Gas Turbine Generator<br />

None<br />

14.3.8.18 Heating, Ventilation, and Air <strong>Co</strong>nditioning<br />

None<br />

14.3.8.19 Inplant <strong>Co</strong>mputer<br />

None<br />

14.3.8.20 Meteorological Monitoring<br />

None<br />

(12)<br />

(22)<br />

(18)<br />

(18,1b)<br />

(18,1b)<br />

(17)<br />

(17)<br />

(18)<br />

(18)<br />

(23)<br />

(3)<br />

(3)<br />

(16)<br />

CON MASTER INDEX Rev 3(wvb)<br />

Page 53 of 61<br />

Ciggi Westinghouse Electric <strong>Co</strong>rp.