SECTION 14<br />
ACCEPTANCE TEST PROCEDURES (cont)<br />
14.3.8.21 Main Generator Auxiliaries<br />
14.3.8.21.1 <strong>Co</strong>re Monitor Failure<br />
14.3.8.22 Main Turbine, Main Steam<br />
None<br />
14.3.8.23 Excore <strong>Nuclear</strong> Instrumentation<br />
14.3.8.23.1 Source Range Blown Fuse (21)<br />
14.3.8.23.2 Source Range Channel High Voltage Failure (21)<br />
14.3.8.23.3 Intermediate Range Channel <strong>Co</strong>mpensating Voltage<br />
Failure<br />
(21)<br />
14.3.8.23.4 Power Range Channel Summing and Level Amp<br />
Failure<br />
(21)<br />
14.3.8.24 <strong>Nuclear</strong> Sampling<br />
None<br />
14.3.8.25 <strong>Plant</strong> <strong>Co</strong>ntrol System<br />
14.3.8.25.1 Variable Heater Reduced Capacity (18)<br />
14.3.8.25.2 B/U Group Heater Reduced Capacity (18)<br />
14.3.8.25.3 TREF Program Failure (17)<br />
14.3.8.25.4 Rod Speed Dead Band CTL Failure (17)<br />
14.3.8.25.5 Rod Speed <strong>Co</strong>ntrol Failure (17)<br />
14.3.8.25.6 Steam Dump Turbine Trip <strong>Co</strong>ntrol Failure (17)<br />
14.3.8.25.7 Steam Dump Load Rej <strong>Co</strong>ntrol Failure (17)<br />
14.3.8.25.8 Steam Dump Arming Solenoid Failure (22)<br />
14.3.8.25.9 Pressurizer Level Programmer Failure (18)<br />
14.3.8.25.10 S/G Level Programmer Failure (22)<br />
14.3.8.25.11 Pressurizer Level <strong>Co</strong>ntroller Failure (18)<br />
14.3.8.25.12 Feedwater Flow <strong>Co</strong>ntroller Failure (22)<br />
14.3.8.25.13 Tavg Bistable Failure (22)<br />
14.3.8.25.14 Feedwater Isolation Failure (9,23)<br />
14.3.8.25.15 Wide Range RTD Faiure (22)<br />
14.3.8.25.16 Wide Range Pressure Failure (22)<br />
14.3.8.25.17 Pressurizer Level Transmitter Failure (High) (22)<br />
14.3.8.25.18 Steamline Flow Transmitter Failure (High) (22)<br />
14.3.8.25.19 Steam Generator Level Transmitter Failure (Low)(22)<br />
14.3.8.25.20 First Stage Press Transmitter Failure (Low) (22)<br />
14.3.8.25.21 Feedline Flow Transmitter Failure (Low) (22)<br />
14.3.8.25.22 S/G Press Transmitter Failure (High) (22)<br />
14.3.8.25.23 <strong>Co</strong>ntainment Press Transmitter Failure (High) (22)<br />
14.3.8.26 <strong>Plant</strong> Protection Logic<br />
14.3.8.26.1 Reactor Trip to Turbine Trip Failure (24)<br />
CON MASTER INDEX Rev 3(wvb) Page 54 of 61<br />
01991 Westinghouse Electric <strong>Co</strong>rp.