ST 16<br />
Technical data<br />
ST 16<br />
Components:<br />
Poles: 2<br />
Rated voltage:<br />
Rated current:<br />
Rated cross-section:<br />
Connection type:<br />
Power<br />
48 V<br />
25 A (for connectors only)<br />
Cable assemblies with fuse holder max. 15 A<br />
2.5 mm 2 fi ne-stranded<br />
Screw, crimp<br />
Connection options: Screw part: min. 0.5 mm mm 2 ;<br />
max. 2.5 mm 2 solid and fi ne-stranded, without ferrules.<br />
Wire stripping length:<br />
7 mm<br />
Approvals: VDE 0711 part 1<br />
(DIN EN 60598-1) in connection with VDE 0609 part 1 (DIN EN 60999),<br />
VDE 0470 part 1 (DIN EN 60529), DIN IEC 352 part 2<br />
Blade-type fuses type C according to DIN 72581 part 3<br />
Transformer: MM, ENEC, VDE, CE<br />
Type of protection: IP 20 according to DIN VDE 0470 part 1/11.92<br />
Material:<br />
Insulation:<br />
Color:<br />
Metal parts:<br />
Screw:<br />
Cable:<br />
Color:<br />
Diameter:<br />
PA 6.6 UL 94 V-0, permanent rigidity<br />
according to DIN VDE 0304, 20,000 h/5,000 h, 100/115 °C<br />
Glow wire test according to DIN VDE 0471 part 21 (IEC 695), 960 °C<br />
White<br />
Silver plated brass<br />
Steel, zinc-plated and chromated<br />
Strands 50 x 0.25 tin-plated,<br />
2 layers halogen-free, fl ame-proof<br />
White<br />
Continuous temperature: 120 °C<br />
Fire load:<br />
3.9 < d < 4.2 mm<br />
0.064 kWh/m<br />
Mounting instruction:<br />
Low-voltage lighting systems are only to be installed by a qualifi ed electrician,<br />
satisfying DIN VDE 0100 part 559 and/or part 559/A2<br />
Electronic transformer see right side.<br />
42