Performance supervision<br />

• During operation the performance deteriorates mainly due to fouling of the<br />

compressor. Dust from the air attaches to the blade surfaces and increases<br />

the flow losses.<br />

• Deterioration also comes from the wear of seals increasing leakages.<br />

©Siemens Power Generation 2003. All Rights Reserved<br />

• The <strong>control</strong> system checks the loss in performance and indicates when it is<br />

time to do a compressor wash<br />

• on line or off line<br />

• Most of the performance is regained at a off line wash, while the on line wash<br />

has less good effect but is used when it is not possible to stop<br />

• The deterioration due to wear is only reduced at overhauls, when blades and<br />

seals are exchanged<br />

25/04/2006<br />