Control system simulations<br />

• The logics are basically figured out of us, the engine designers, but the logics<br />

is programmed by others<br />

• There will be errors both in the logics and the programming<br />

• Simulations to check it can be done in simple or sophisticated ways<br />

©Siemens Power Generation 2003. All Rights Reserved<br />

• In the simple way an Excel program can be used<br />

• The gas <strong>turbine</strong> performance is calculated at small time steps<br />

•0.5 sec at fast transients (valve openings)<br />

•1 sec at normal start sequences (acceleration and trip)<br />

•10 sec at normal loading<br />

• Usually the rotor mass can be neglected (not at load rejection)<br />

25/04/2006<br />