01.12.2014 Views

OI Catalog - Olson Instruments, Inc.

OI Catalog - Olson Instruments, Inc.

OI Catalog - Olson Instruments, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

nondestructive testing platforms<br />

Concrete NDE 360 Thickness » One Platform Gauges -(CTG) Multiple » Standard NDE Tests Models<br />

The CTG line of instruments are handheld, battery powered, nondestructive systems for measuring<br />

the thickness and integrity of concrete slabs, pavements, tunnel linings, walls and other<br />

plate-like structures using the Impact Echo (IE) principle.<br />

Concrete Thickness/Flaw Gauges are<br />

dedicated platforms designed to test concrete<br />

thickness in straightforward situations that involve<br />

simple structures like slabs, pipes, or walls. All models<br />

include a telescoping pole for overhead or flatwork.<br />

Perform over 60 CTG tests in an hour on-site, without the<br />

need to core, drill, or excavate! Save time and money using<br />

<strong>Olson</strong>’s CTG Thickness/Flaw Gauges — see our Impact<br />

Echo section (see page 24) for more information about the<br />

methodology. To receive a brochure on the CTG product<br />

line, email info@<strong>Olson</strong><strong>Instruments</strong>.com, or call 303.423.1212.<br />

Standard Model<br />

Impact Echo Test Head<br />

CTG-1TF (Thickness/Flaw Model)<br />

Specifications<br />

»» Standard Thickness Range: 3.2" to 6 ft (81 mm to 1.8 m -<br />

Normal solenoid mode to thick hammer mode<br />

CTG Test Gauge<br />

Features:<br />

■■<br />

■■<br />

■■<br />

■■<br />

■■<br />

■■<br />

■■<br />

■■<br />

■■<br />

■■<br />

Ruggedized, handheld test head with integrated displacement<br />

transducer and solenoid impactor<br />

No coupling agents required for use of test head on concrete<br />

Works on cured, hardened concrete in air or on grade<br />

Works through thin, bonded paint and most types of bonded<br />

tile – checks tile bonding too<br />

Easy to read transflective LCD display for outdoors and<br />

switchable backlight for indoors<br />

Switch between English (inches) or Metric<br />

(centimeters) units with the click of a button<br />

Easy velocity calibration at known thickness location,<br />

or use <strong>Olson</strong>’s default parameters<br />

Download test time/date and results into your PC through<br />

serial port (serial cable and serial/USB cable)<br />

Thickness data table can be imported into popular<br />

spreadsheet programs<br />

Outputs thickness summary tables and data for postprocessing<br />

on a Windows PC using WinIE software<br />

»»Accuracy:<br />

± 2% at high resolution when IE velocity is<br />

calibrated on a known thickness<br />

»»Report Capability:<br />

Numerical thickness summary table<br />

downloadable to spreadsheet<br />

Raw data downloadable to PC/Notebook for flaw<br />

analyses using <strong>Olson</strong>’s Windows based WinIE software<br />

and thickness summary table<br />

»»Power:<br />

Internal rechargeable NiMH battery pack<br />

(~ 6-7 hrs of operation per charge), external battery<br />

charger (AC power unit, overnight charging), can use<br />

10 - AA size alkaline batteries or run on the AC power unit<br />

»» Learning Curve: Less than 10 minutes for thickness<br />

measurements!<br />

»»Frequency Resolution: 44.5 Hz (high) or 89 Hz (low)<br />

»»Number of Samples Acquired Per Test:<br />

256 (normal) or 512 (high resolution with zero padding)<br />

»»Processing Time for 1 Test: ~ 3 seconds<br />

»»Sampling Rates: 45,600 samples/s (normal), 14,400<br />

samples/s (thick), and 116,000 samples/s (super thin)<br />

»»Maximum Signal Frequency: 22,800 Hz (normal),<br />

7,200 Hz (thick), and 58,000 Hz (super thin)<br />

»» Weight: 4.4 lbs (2.0 kg) combined for test head and gauge<br />

»»Cable Length for Test Head: 6 ft (1.8 m)<br />

6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!