OI Catalog - Olson Instruments, Inc.
OI Catalog - Olson Instruments, Inc.
OI Catalog - Olson Instruments, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
nondestructive testing platforms<br />
Concrete NDE 360 Thickness » One Platform Gauges -(CTG) Multiple » Standard NDE Tests Models<br />
The CTG line of instruments are handheld, battery powered, nondestructive systems for measuring<br />
the thickness and integrity of concrete slabs, pavements, tunnel linings, walls and other<br />
plate-like structures using the Impact Echo (IE) principle.<br />
Concrete Thickness/Flaw Gauges are<br />
dedicated platforms designed to test concrete<br />
thickness in straightforward situations that involve<br />
simple structures like slabs, pipes, or walls. All models<br />
include a telescoping pole for overhead or flatwork.<br />
Perform over 60 CTG tests in an hour on-site, without the<br />
need to core, drill, or excavate! Save time and money using<br />
<strong>Olson</strong>’s CTG Thickness/Flaw Gauges — see our Impact<br />
Echo section (see page 24) for more information about the<br />
methodology. To receive a brochure on the CTG product<br />
line, email info@<strong>Olson</strong><strong>Instruments</strong>.com, or call 303.423.1212.<br />
Standard Model<br />
Impact Echo Test Head<br />
CTG-1TF (Thickness/Flaw Model)<br />
Specifications<br />
»» Standard Thickness Range: 3.2" to 6 ft (81 mm to 1.8 m -<br />
Normal solenoid mode to thick hammer mode<br />
CTG Test Gauge<br />
Features:<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
■■<br />
Ruggedized, handheld test head with integrated displacement<br />
transducer and solenoid impactor<br />
No coupling agents required for use of test head on concrete<br />
Works on cured, hardened concrete in air or on grade<br />
Works through thin, bonded paint and most types of bonded<br />
tile – checks tile bonding too<br />
Easy to read transflective LCD display for outdoors and<br />
switchable backlight for indoors<br />
Switch between English (inches) or Metric<br />
(centimeters) units with the click of a button<br />
Easy velocity calibration at known thickness location,<br />
or use <strong>Olson</strong>’s default parameters<br />
Download test time/date and results into your PC through<br />
serial port (serial cable and serial/USB cable)<br />
Thickness data table can be imported into popular<br />
spreadsheet programs<br />
Outputs thickness summary tables and data for postprocessing<br />
on a Windows PC using WinIE software<br />
»»Accuracy:<br />
± 2% at high resolution when IE velocity is<br />
calibrated on a known thickness<br />
»»Report Capability:<br />
Numerical thickness summary table<br />
downloadable to spreadsheet<br />
Raw data downloadable to PC/Notebook for flaw<br />
analyses using <strong>Olson</strong>’s Windows based WinIE software<br />
and thickness summary table<br />
»»Power:<br />
Internal rechargeable NiMH battery pack<br />
(~ 6-7 hrs of operation per charge), external battery<br />
charger (AC power unit, overnight charging), can use<br />
10 - AA size alkaline batteries or run on the AC power unit<br />
»» Learning Curve: Less than 10 minutes for thickness<br />
measurements!<br />
»»Frequency Resolution: 44.5 Hz (high) or 89 Hz (low)<br />
»»Number of Samples Acquired Per Test:<br />
256 (normal) or 512 (high resolution with zero padding)<br />
»»Processing Time for 1 Test: ~ 3 seconds<br />
»»Sampling Rates: 45,600 samples/s (normal), 14,400<br />
samples/s (thick), and 116,000 samples/s (super thin)<br />
»»Maximum Signal Frequency: 22,800 Hz (normal),<br />
7,200 Hz (thick), and 58,000 Hz (super thin)<br />
»» Weight: 4.4 lbs (2.0 kg) combined for test head and gauge<br />
»»Cable Length for Test Head: 6 ft (1.8 m)<br />
6