04.12.2014 Views

Planning Documents for Hybrid OR

This Planning Document was developed to enhance your knowledge of the Dräger portfolio and to provide guidance when designing a new Hybrid OR. This document contains an overview of Dräger products and their corresponding technical data. The last pages of this document show several exemplary Dräger solutions, including detailed technical drawings of the individual workplaces.

This Planning Document was developed to enhance your knowledge of the
Dräger portfolio and to provide guidance when designing a new Hybrid OR.
This document contains an overview of Dräger products and their corresponding
technical data.
The last pages of this document show several exemplary Dräger solutions,
including detailed technical drawings of the individual workplaces.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

D-441-2014<br />

ST-8934-2008<br />

D-35487-2011<br />

<strong>Planning</strong> <strong>Documents</strong><br />

<strong>for</strong> <strong>Hybrid</strong> <strong>OR</strong>


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | PREAMBLE | 3<br />

Preamble<br />

This <strong>Planning</strong> Document was developed to enhance your knowledge of the<br />

Dräger portfolio and to provide guidance when designing a new <strong>Hybrid</strong> <strong>OR</strong>.<br />

This document contains an overview of Dräger products and their corresponding<br />

technical data.<br />

The last pages of this document show several exemplary Dräger solutions,<br />

including detailed technical drawings of the individual workplaces.


4 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

INDEX OF CONTENTS<br />

INDEX OF CONTENTS<br />

OVERVIEW<br />

<strong>Hybrid</strong> <strong>OR</strong> – The concept of <strong>Hybrid</strong> <strong>OR</strong> 6<br />

Dräger – Workplace infrastructure 7<br />

DRÄGER P<strong>OR</strong>TFOLIO 8<br />

Overview Supply units 10<br />

<strong>OR</strong> lights and video systems/Gas Management Systems 11<br />

Ceiling supply units <strong>for</strong> the <strong>OR</strong> 12<br />

<strong>OR</strong> and examination lights 14<br />

Central axis system dedicated <strong>for</strong> <strong>Hybrid</strong> <strong>OR</strong> 16<br />

Display holder 18<br />

Ceiling fixtures 20<br />

Workstation components 23<br />

Gas Management Systems 26<br />

Overview anesthesia portfolio 28<br />

Accessories 30<br />

W<strong>OR</strong>KPLACE EXAMPLES 32<br />

Supply units Anesthesia/Docking 34<br />

Surgical workplace 35<br />

Display holder/<strong>OR</strong> lights 36<br />

Anesthesia devices 37<br />

GENERAL PLANNING 38<br />

General <strong>Planning</strong>: Ceiling supply units, <strong>OR</strong> lights/Cameras/Displays, 40<br />

Ceiling mount<br />

<strong>Planning</strong> an anesthesia workplace 41<br />

Solution 1: Siemens – Artis zee floor arrangement – 42<br />

supply unit arrangement with <strong>OR</strong> lights and display boom<br />

Solution 2: Siemens – Artis zee ceiling arrangement – 44<br />

supply unit arrangement with <strong>OR</strong> lights and display boom<br />

Solution 3: Siemens – Artis zee ceiling arrangement – 46<br />

supply unit MediaDocking arrangement with <strong>OR</strong> lights and display boom<br />

Solution 4: Siemens – Artis zeego 30° arrangement – 48<br />

supply unit arrangement with <strong>OR</strong> lights and display boom<br />

Solution 5: Siemens – Artis zeego parallel arrangement – 50<br />

supply unit MediaDocking arrangement with <strong>OR</strong> lights and display boom


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | INDEX OF CONTENTS | 5<br />

INDEX OF CONTENTS<br />

GENERAL PLANNING<br />

Solution 6: Philips – Allura FD 20 ceiling arrangement – 52<br />

supply unit arrangement with <strong>OR</strong> lights and display booms<br />

Solution 7: Philips – Allura FD 20 FlexMove arrangement – 54<br />

supply unit arrangement with <strong>OR</strong> lights and display booms<br />

Solution 8: Philips – Allura FD 20 FlexMove arrangement – 56<br />

supply unit arrangement with <strong>OR</strong> lights and display booms<br />

Solution 9: Philips – Allura FD 20 FlexMove arrangement – 58<br />

supply unit arrangement with <strong>OR</strong> lights and display booms<br />

CAD Drawing – Configuration 1, Movita - Radiation Protection 60<br />

CAD Drawing – Configuration 2, Movita - Pendula Cardiotechnology Type 61<br />

CAD Drawing – Configuration 3, Movita - Pendula - Radiation Protect 62<br />

CAD Drawing – Configuration 4, Polaris® 500/700 63<br />

CAD Drawing – Configuration 5, Movita - Cardiotechnology Type 64<br />

CAD Drawing – Configuration 6, Movita - Polaris® 500 - Radiation Protection 65<br />

CAD Drawing – Configuration 7, Pendula 60" - Polaris® 700 66<br />

CAD Drawing – Configuration 8, Movita - Forta Cardiotechnology Type 67<br />

CAD Drawing – Configuration 9, Polaris® 500 - Radiation Protection 68<br />

CAD Drawing – Configuration 10, Forta MD 69<br />

CAD Drawing – Configuration 11, Pendula 60" 70<br />

CAD Drawing – Configuration 12, Forta MD - Polaris® 500 - 71<br />

Radiation Protection<br />

CAD Drawing – Configuration 13, Movita - Forta Cardiotechnology Type 72<br />

CAD Drawing – Configuration 14, Radiation Protection 73<br />

CAD Drawing – Configuration 15, Pendula - Forta MD - Polaris® 700 74<br />

CAD Drawing – Configuration 16, Pendula - Forta MD - Polaris® 500 75<br />

CAD Drawing – Configuration 17, Movita 10 (Lift) 76<br />

CAD Drawing – Configuration 18, Pendula 60" - Polaris® 750 77<br />

CAD Drawing – Configuration 19, Pendula 19" - Polaris® 500 78<br />

CAD Drawing – Configuration 20, Movita 05 (Lift) 79<br />

CAD Drawing – Configuration 21, Movita 10 (Lift) 80<br />

CAD Drawing – Configuration 22, Polaris® 750 81<br />

CAD Drawing – Configuration 23, Pendula 60" 82<br />

CAD Drawing – Configuration 24, Movita 10 (Lift) 83<br />

CAD Drawing – Configuration 25, Agila 05 (Lift) - Polaris® 500 84<br />

CAD Drawing – Configuration 26, Movita 05 (Lift) - Movita AK (Lift) 85<br />

CAD Drawing – Configuration 27, Pendula 60" - Pendula 19" 86<br />

CAD Drawing – Configuration 28, Polaris® 500 87<br />

CONTACT 89


6 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

OVERVIEW<br />

<strong>Hybrid</strong> <strong>OR</strong><br />

The concept of <strong>Hybrid</strong> <strong>OR</strong>:<br />

“The fusion of surgery and imaging”<br />

OPERATING ROOM<br />

IMAGING<br />

SURGICAL W<strong>OR</strong>KPLACE<br />

Equipment<br />

– <strong>OR</strong> lights and cameras<br />

– Video Management/<strong>OR</strong>-Integration<br />

– Displays<br />

– <strong>OR</strong> tables<br />

– Navigation<br />

– <strong>OR</strong> robots<br />

– Blood gas analysis device<br />

– ECMO<br />

– ECG device<br />

– HF surgical equipment<br />

– Minimal invasive surgery<br />

equipment<br />

– Suction unit<br />

– Ultrasound diagnosis/<br />

echocardiography device<br />

– Equipment table<br />

– Defibrillator<br />

– Heart lung machine<br />

<strong>Hybrid</strong> <strong>OR</strong><br />

CARDIO/ANGIO W<strong>OR</strong>KPLACE<br />

Equipment<br />

– CT, special C-arm<br />

– Catheter trolley/tables<br />

– High-pressure injection needle<br />

– Pneumatic blood arrest<br />

ANESTHESIA W<strong>OR</strong>KPLACE<br />

– Anesthesia device<br />

– Patient monitoring and IT<br />

– Infusion/syringe pumps


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | OVERVIEW | 7<br />

Dräger<br />

Workplace infrastructure<br />

Dräger offers solutions <strong>for</strong> the entire hospital<br />

D-30018-2011


8 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Dräger<br />

portfolio<br />

D-35628-2011


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 9<br />

Dräger portfolio<br />

Dräger portfolio<br />

An overview of the Dräger portfolio <strong>for</strong> the <strong>OR</strong><br />

<strong>Planning</strong> a <strong>Hybrid</strong> <strong>OR</strong> requires a thorough understanding<br />

of the Dräger product portfolio. This<br />

chapter will help you familiarize yourself with<br />

Dräger products and devices which are relevant <strong>for</strong><br />

the operating room, such as supply units, <strong>OR</strong> lights,<br />

ceiling fixtures, gas management systems and<br />

anesthesia devices.<br />

We encourage you to take a close look at the<br />

Dräger products discussed in this chapter in order<br />

to maximize your potential planning competency.


10 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Overview<br />

Supply units<br />

D-3289-2011<br />

Ponta<br />

D-148-2010<br />

MT-5960-2008<br />

MT-6342-2008<br />

Opera®<br />

Agila<br />

Movita<br />

D-18477-2010<br />

D-36069-2011<br />

D-27741-2009<br />

Forta<br />

Linea<br />

Gemina® Duo


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 11<br />

<strong>OR</strong> lights and video systems<br />

Dräger portfolio<br />

MT-6323-2008<br />

D-58476-2012<br />

D-31307-2011<br />

D-21704-2010<br />

Video systems<br />

Polaris® 50<br />

Polaris® 100/200<br />

Polaris® 5xx/7xx<br />

Gas Management Systems<br />

D-9489-2009<br />

D-9270-2009<br />

Terminal Units<br />

EcoPharm Tower<br />

D-9368-2009<br />

MT-0001-2006<br />

D-58913-2012<br />

Medical Air Guard<br />

Gas Control Station<br />

Area Control Unit with VoluCount®


12 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Ceiling supply units <strong>for</strong> the <strong>OR</strong><br />

D-52660-2012<br />

MT-6342-2008<br />

D-18460-2010<br />

Agila<br />

Movita<br />

Forta<br />

WHAT IS WHAT?<br />

Ceiling bearing<br />

Arm system<br />

Distance tube<br />

Lifting<br />

system<br />

Media head<br />

Media column<br />

D-18369-2010<br />

D-12307-2011<br />

Workstation<br />

components<br />

D-18551-2010


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 13<br />

ARM SYSTEMS<br />

D-52660-2012<br />

D-52660-2012<br />

Single arm system<br />

Arm length: 500 mm, 750 mm, 1000 mm, 1250 mm<br />

Load capacity*: 120 kg - 270 kg<br />

Double arm system<br />

Arm length: min. 1000 mm - max. 2500 mm<br />

Load capacity*: 120 kg - 270 kg<br />

Dräger portfolio<br />

D-18369-2010<br />

Lift arm system<br />

Arm length: min. 1000 mm (lift arm) - max. 2500 mm<br />

Load capacity*: 80 kg - 270 kg<br />

*Load capacity = net load at media column/head<br />

strong<br />

medium<br />

light<br />

Arm types<br />

For single and double arm systems, you can choose between heavy-duty,<br />

medium and lightweight models. Load capacities are defined by the type<br />

of and length of arm.<br />

MT-5963-2008<br />

MT-6342-2008<br />

D-18468-2010<br />

Agila<br />

Movita<br />

Forta<br />

TECHNICAL DATA<br />

Product Agila Movita Forta<br />

Load capacity<br />

Media head 120 kg 120 kg –<br />

Column 120 kg 270 kg 270 kg<br />

Lift express/Lift 80 kg/120 kg 80 kg/180 kg –<br />

Lift speed 10/20 sec 10/20 sec 30 sec<br />

Height adjustment 600 mm 600 mm 600 mm<br />

Media outlets up to 51 up to 102 up to 32


14 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

<strong>OR</strong> and examination lights<br />

LIGHTS AND VIDEO OPTIONS<br />

D-21696-2010<br />

Video systems<br />

D-31029-2011<br />

D-58477-2012<br />

D-448-2014<br />

Polaris® 5xx/7xx<br />

Polaris® 100/200<br />

Polaris® 50<br />

TECHNICAL DATA<br />

Product Polaris® 5xx/7xx Polaris® 100/200 Polaris® 50<br />

Technology LED LED LED<br />

Light intensity 110.000 or 160.000 Lux 120.000 or 160.000 Lux 60.000 Lux<br />

Endo-light mode 3.000 Lux 300 Lux no<br />

Light field diameter 220 to 290 mm 200 mm 160 mm<br />

Color temperature 4600 K 4400 K or 5000 K or 5600 K (option) 4500 K<br />

Video options integrated SD or HD camera, external SD camera external SD camera no


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 15<br />

D-21698-2010<br />

Dräger portfolio<br />

CENTRAL AXIS MODELS<br />

Central axis system<br />

– For Polaris, camera and displays,<br />

central axes are available<br />

Swivel arms<br />

– You can choose from 1 up to 4-fold axis.<br />

Standard length: 700, 850, 1000, 1150<br />

and 1450 mm<br />

Arm system<br />

Swivel arm length (mm)<br />

1-fold central axis (ø 110 mm) 850<br />

1150<br />

1450<br />

AC 2000/3000 1-fold 750<br />

2-fold central axis 700/850<br />

3-fold central axis 700/850/1000<br />

4-fold central axis 700/850/1000/1150<br />

All central axes are freely configurable. Display holders, external cameras, X-Ray protection shields or <strong>OR</strong> lights can be mounted on each position.<br />

A display holder must be to be mounted at either the lowest or highest position.


16 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

D-90850-2013<br />

D-442-2014<br />

Central axis system dedicated <strong>for</strong> <strong>Hybrid</strong> <strong>OR</strong><br />

Several axes especially designed <strong>for</strong> use in <strong>Hybrid</strong> <strong>OR</strong> are available.<br />

You can choose between a 1 and 2-fold axis. Available lengths: 1300 to 2200 mm<br />

These axes are also useful if two mounting points are outside the LAF-field (left and right)


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 17<br />

D-22405-2010<br />

Dräger portfolio<br />

Arm system<br />

Swivel arm length (mm)<br />

1-fold central axis 1300<br />

1400<br />

–<br />

2200<br />

2-fold central axis 1150/1300<br />

1300/1450<br />

–<br />

2050/2200<br />

SPRING ARMS<br />

Light heads and display holders are<br />

mounted on swivel arms using spring arms.<br />

Spring arm length: approx. 910 mm<br />

(<strong>OR</strong> lights)


18 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Display holder<br />

D-57969-2012<br />

D-90843-2013<br />

Pendula<br />

Display holder at CSU<br />

D-90844-2013<br />

D-069-2014<br />

Display holder at central axis (up to 24")<br />

Display holder at central axis (up to 32")<br />

PENDULA – CUSTOM SOLUTIONS F<strong>OR</strong> THE HYBRID <strong>OR</strong><br />

FEATURES<br />

– Stationary ceiling mount<br />

– Spring arm adapted to Dräger arm<br />

– Freely suspended system that swings away<br />

(horizontally and vertically) in case of<br />

collisions<br />

– The swinging mount underneath the lift<br />

arm supports the automatic upright positioning<br />

of the system and protect the displays<br />

and other equipment in case of collisions<br />

– Integrated cable management<br />

– Flexible arrangement of the displays in<br />

number and size (2-8 displays (19"/21") or<br />

1 x 60" + backup screens)


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 19<br />

D-35818-2011<br />

D-57963-2012<br />

D-57972-2012<br />

Dräger portfolio<br />

Front view 3-fold<br />

Front view 60 inch<br />

Front view 8-fold<br />

D-35825-2011<br />

D-57962-2012<br />

Back view 3-fold<br />

Back view 60 inch<br />

D-450-2014<br />

D-57973-2012<br />

Back view 8-fold<br />

VARIANTS<br />

– 4 arm lengths: 1750 mm-2500 mm<br />

– 7 display frames<br />

– 2-8 displays optimized <strong>for</strong> 19";<br />

21" displays can be also mounted<br />

– 60" large display<br />

Advice: If there is an <strong>Hybrid</strong> <strong>OR</strong> with an<br />

Angiography System from Philips a large<br />

screen (FlexVision) must be used which<br />

need its own display frame!<br />

FlexVision<br />

TECHNICAL DATA<br />

Product Pendula Display holder at CSU Display arm at central axis<br />

Description Multi display holder Swivel and lift arms mounted on CSU Display arm at central axis<br />

Display sizes 19" up to 60" approx. 26" (VESA 100 adaptor), approx. 24" (larger displays<br />

max. 15 kg<br />

on request)<br />

Display quantity 1 (60") up to 8 (21") depending on column size 1 (19 to 32”) or 2 (19 to 24”)<br />

Fixation analogue to CSU fixation at CSU – Media column at central axis of <strong>OR</strong> light<br />

or separate


20 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Ceiling fixtures<br />

Ceiling fixtures <strong>for</strong> supply units<br />

PRODUCT DESCRIPTION<br />

The universal Dräger ceiling mount supports<br />

the installation of Agila, Motiva and Forta<br />

supply units as well as the Pendula. They are<br />

designed <strong>for</strong> either anchor (fig. B + D) or boltthrough<br />

(fig. A + C) mounting. The ceiling<br />

supply can be directly attached to a concrete<br />

ceiling (direct mounting, see A1 and B1 in<br />

figure below).<br />

A variable fixture kit enables mounting up to<br />

1200 mm under the concrete ceiling in order<br />

to bridge the space between it and a false<br />

ceiling. A media flange, located between the<br />

raw and false ceilings, offers enough space <strong>for</strong><br />

connecting supply voltage, medical gas, vacuum<br />

and data cables. The installation manuals<br />

are included in the delivery.<br />

PLANNING GUIDELINES<br />

Dräger ceiling supply units are validated and<br />

certified <strong>for</strong> use with these ceiling fixtures.<br />

This certification is invalidated if non-Dräger<br />

ceiling mounting systems are used.<br />

The ceiling mount must meet the following<br />

criteria:<br />

– 12.500 Nm of torque at the lower end<br />

of the fixture<br />

– 9.000 N tensile <strong>for</strong>ce at the ceiling<br />

If the building design is not compatible with<br />

a Dräger ceiling mount, a custom design can<br />

be substituted. Certification of the two conditions<br />

stated above is mandatory. The per<strong>for</strong>mance<br />

specifications of a Dräger ceiling<br />

supply unit cannot be guaranteed if a mounting<br />

design is used which does not meet the<br />

required criteria listed above. In such cases,<br />

any given approvals are automatically invalidated.<br />

Available <strong>for</strong>:<br />

– Anchor mounting: Anchor mounting is<br />

possible if the ceiling is constructed<br />

with at least 250 mm of B 25 concrete<br />

– Bolt-through mounting: Bolt-through<br />

mounting is required if the ceiling<br />

thickness is less than 250 mm or the<br />

concrete quality is less than B 25.<br />

Without ceiling fixture set<br />

With ceiling fixture set<br />

A<br />

C<br />

Nm<br />

max. 1200 mm<br />

Bolt-through mounting<br />

N<br />

B<br />

D<br />

Anchor mounting<br />

TECHNICAL DATA<br />

Product<br />

Span intermediate ceiling distance<br />

Max. torque<br />

Max. tensile <strong>for</strong>ce at the ceiling<br />

Hole pattern<br />

Ceiling fixtures<br />

up to 1.200 mm<br />

12.500 Nm<br />

9.000 N<br />

Ø 470 mm


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 21<br />

Ceiling hood/Flat cover<br />

Dräger portfolio<br />

TYPES OF CEILING COVERS<br />

D-90841-2013<br />

D-90845-2013<br />

D-90848-2013<br />

D-90849-2013<br />

D-90846-2013<br />

Ceiling hood (height: 170 mm)<br />

Flat cover (height: 2 mm)<br />

Single/double/triple CSU<br />

Dräger ceiling fixtures are designed <strong>for</strong><br />

universal compatability. You can choose<br />

between single, double or triple type.<br />

Single CSU<br />

Double CSU<br />

Double CSU with third arm<br />

OPTIONS<br />

Single Double Triple<br />

CSU<br />

CSU/CSU<br />

Light CSU /Light CSU /CSU /Light<br />

Display CSU /Display CSU /CSU /Display<br />

X-Ray protection CSU /X-Ray protection CSU /CSU /X-Ray protection


22 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Ceiling fixtures <strong>for</strong> <strong>OR</strong> lights/display arms<br />

PRODUCT DESCRIPTION<br />

The Dräger ceiling mount supports the installation<br />

of lights and display holders (on the<br />

central axis). The <strong>OR</strong> light/display arm can be<br />

fixed directly under the concrete ceiling<br />

(direct mounting). The distance tube allows<br />

mounting at heights of up to 1200 mm under<br />

a concrete ceiling in order to bridge the space<br />

above a false ceiling. The installation manuals<br />

are included with delivery.<br />

MOUNTING OPTIONS<br />

Direct mount<br />

This system is recommended as a direct<br />

mount or <strong>for</strong> use with a false ceiling up to a<br />

distance of 600 mm between the concrete<br />

and false ceiling or in combination with a laminar<br />

flow system. The suspension tube is available<br />

in five standard lengths (220/460/630/<br />

800/1000 mm). For service purposes, it<br />

should be considered that the electrical components<br />

must be installed in a switch box near<br />

the <strong>OR</strong> (max. 40 m).<br />

D-90851-2013<br />

With ceiling cover<br />

D-90851-2013<br />

With flat cover<br />

With laminar flow ceiling<br />

Distance tube<br />

This system is recommended <strong>for</strong> use with distances<br />

> 600 mm between the concrete and<br />

false ceiling or in combination with a laminar<br />

flow system. The distance tube is available in<br />

two standard lengths (600/1200 mm). For<br />

service purposes, it should be considered that<br />

the electrical components must be installed in<br />

a switch box near the <strong>OR</strong> (max. 40 m).<br />

D-90851-2013<br />

D-90851-2013<br />

With ceiling cover<br />

With flat cover<br />

With laminar flow ceiling<br />

Axis system Arm lengths Spring load arm lengths Vertical <strong>for</strong>ce (F) Torque (M)<br />

1-fold axis<br />

1f axis xxx 850 mm 930 mm 960 N 910 Nm<br />

1f axis AC2000 display 700 mm 930 mm 870 N 460 Nm<br />

1f axis AC3000 display 750 mm 930 mm 940 N 700 Nm<br />

1f axis xxx 1150 1150 mm 930 mm 1000 N 760 Nm<br />

1f axis xxx 1450 1450 mm 930 mm 1030 N 640 Nm<br />

2-fold axis<br />

2f axis xxx/xxx 700/850 mm 930 mm 1530 N 1280 Nm<br />

2f axis xxx/xxx 1150 700/1150 mm 930 mm 1400 N 1260 Nm<br />

3-fold axis<br />

3f axis xxx/xxx/xxx 700/850/1000 mm 930 mm 1920 N 1850 Nm<br />

4-fold axis<br />

4f axis xxx/xxx/xxx/xxx 700/850/1000/1150 mm 930 mm 2490 N 2680 Nm


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 23<br />

Workstation components<br />

Dräger offers a wide range of workstation components. These components are freely<br />

configurable and help to ensure an ergonomic workplace design.<br />

Dräger portfolio<br />

SHELVES<br />

D-27735-2009<br />

D-27733-2009<br />

D-27732-2009<br />

Our shelf portfolio includes a wide range of options. You can choose from different shelf sizes, the number of standard rails or<br />

add drawers according to your needs.<br />

SHELF SIZES/UASBLE SURFACE (W X D)<br />

430 x 340 mm<br />

630 x 340 mm<br />

430 x 480 mm<br />

530 x 480 mm<br />

630 x 480 mm<br />

860 x 480 mm<br />

STANDARD RAILS<br />

no rails<br />

side rails<br />

front rail<br />

control handles at front<br />

DRAWER OPTIONS<br />

1 drawer<br />

1 drawer with lock (incl. 2 keys)<br />

2 drawers<br />

2 drawers and 1 lock<br />

2 drawers and 2 locks<br />

drawers and 2 locks on a shelf<br />

(860 x 480 mm)<br />

1 drawer and 1 documentation module<br />

1 documentation module<br />

D-26256-2009


24 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

ARM TYPES<br />

INFUSION ARMS<br />

For all infusion arms, the options are almost<br />

limitless. These arms are available in both<br />

single- and double-arm configurations. Additionally,<br />

you can select the desired swivel arm<br />

length: 200/300/400 mm. All arms feature<br />

adjustable friction brakes (ball bearings) and<br />

integrated cable management.<br />

D-32268-2011<br />

Double swivel arm <strong>for</strong> 25 mm pole (infusion), mounted on a 38 mm pole<br />

MONIT<strong>OR</strong> ARMS<br />

For all monitor arms, a variety of options are<br />

available. These arms are available as lifting<br />

arms or lifting arms with additional swivel arm.<br />

You can also choose an optional keyboard holder.<br />

Additionally, you can select the desired<br />

swivel arm length: 200/300/400 mm. All<br />

arms feature adjustable friction brakes (ball<br />

bearings) and integrated cable management.<br />

D-111-2010


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 25<br />

CABLE MANAGEMENT<br />

D-26583-2009<br />

D-26600-2009<br />

Dräger portfolio<br />

Cable channel<br />

Cable boxes<br />

COL<strong>OR</strong> CODE CONCEPT<br />

D-18601-2010<br />

Handles<br />

2-1298-94, 2-1201-94, 2-1065-96<br />

D-18609-2010<br />

Control at column<br />

ACCESS<strong>OR</strong>IES<br />

In addition to the components mentioned<br />

above, further components are available<br />

(e.g. infusion poles, application rods, racks,<br />

clamping rails, equipment holders etc.).<br />

Compact rail, cable holder, rail holder


26 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Gas Management Systems<br />

Dräger Gas Management Systems (GMS) are designed to manage<br />

the hospital’s gas supply needs. Dräger offers complete gas supply<br />

systems which include all necessary components and distribution<br />

piplines.<br />

MT-0018-2006<br />

Gas Terminal Units<br />

<strong>Planning</strong> and designing Gas Management<br />

Systems <strong>for</strong> either complete hospitals or<br />

individual areas like a new IC or <strong>OR</strong> area is<br />

a challenging task. Different international<br />

standards and guidelines provide different<br />

in<strong>for</strong>mation, require different system configurations<br />

and different approaches to all the<br />

challenges occurring.<br />

Dräger is at your side when it comes to solving<br />

these challenges and optimizing the system<br />

design <strong>for</strong> the benefit of the hospital.<br />

We have more than 50 years experience in<br />

designing, building and testing Gas<br />

Management Systems.<br />

As every project is different and the systems<br />

tailor-made <strong>for</strong> the hospital, it is difficult to<br />

provide generic planning details. There<strong>for</strong>e<br />

we kindly ask you to contact your local<br />

Dräger representative <strong>for</strong> individual planning<br />

support.<br />

GAS TERMINAL UNITS<br />

The locations and quantities of gas terminal<br />

units are essential parts of the planning of<br />

every Gas Management System. Depending<br />

on the clinical procedures and applications,<br />

different gases are required in different hospital<br />

areas and the amount of units provided<br />

needs to match processes and devices used<br />

there. Dräger builds world-renowned gas terminal<br />

units since over 40 years and is offering<br />

outlets according to DIN, British Standard and<br />

other international types.<br />

D-1217-2009<br />

Alarm Management<br />

ALARM MANAGEMENT SYSTEM<br />

A complex system like a medical Gas<br />

Management System requires good operational<br />

management and provides a host of in<strong>for</strong>mation.<br />

Dräger Alarm Management Systems<br />

consolidate all this in<strong>for</strong>mation like operational<br />

and emergency alarms. Analogue operational<br />

data (e.g. pressure and flow) can also easily<br />

be integrated. All in<strong>for</strong>mation can be displayed<br />

where ever required with LED-, text- or touch<br />

display monitors and connected to integrated<br />

building management systems.<br />

D-16746-2010<br />

Distribution systems<br />

DISTRIBUTION SYSTEM<br />

Medical grade copper tubes according to ISO<br />

13348 with defined cleanliness and thorough<br />

testing regime in combination with high quality<br />

installation (e.g. inert gas shielding during<br />

welding) <strong>for</strong>m the backbone of the infrastructure<br />

which ensures that all gases are<br />

available at the required points of use. Proper<br />

system calculation according to Dräger<br />

Design Guidelines and international standards<br />

and comprehensive testing and installation<br />

ensure quality and per<strong>for</strong>mance of the overall<br />

system.


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 27<br />

D-507-2014<br />

MT-7526-2004<br />

Dräger portfolio<br />

Reliable monitoring throughout the entire system<br />

AREA CONTROL UNITS<br />

All clinical areas need to be controlled individually<br />

by Area Control Units. This includes<br />

pressure gauges <strong>for</strong> each gas and alarms <strong>for</strong><br />

pressure deviations as well as lock-off valves<br />

and emergency inlet points.<br />

MT-5164-2004<br />

MT-5206-2004<br />

D-1216-2009<br />

Vacuum pumps<br />

Compressed air system<br />

Cylinder Manifold <strong>for</strong> oxygen<br />

VACUUM SYSTEM<br />

Vacuum is indispensable <strong>for</strong> surgical application<br />

(wound field aspiration) as well as bronchus<br />

suctioning in anaesthesia and intensive<br />

care treatment. Dräger vacuum systems with<br />

triplex or quadruplex pumps fulfill the ISO<br />

7396-1 and match all requirements in terms of<br />

safety and efficiency.<br />

COMPRESSED AIR SYSTEM<br />

Medical air systems <strong>for</strong> breathing purpuoe<br />

(4/5 bar) as well as <strong>for</strong> surgical tool air (7/8<br />

bar) must fulfill the ISO 7396-1, breathing air<br />

must also comply with the European Pharmacopoiea.<br />

Dräger medical air systems combine<br />

proven design, safe operations, and efficient<br />

reliability.<br />

CYLINDER MANIFOLDS<br />

Oxygen, Nitrous Oxyde and Carbon Dioxide<br />

can be supplied by 3-fold cylinder manifolds<br />

or by a liquid oxygen tank (V.I.E.) and a 2-fold<br />

cylinder manifold with a Dräger Gas Control<br />

Station as the core of the system.


28 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

Overview anesthesia portfolio<br />

ANESTHESIA DEVICES<br />

D-11215-2010<br />

D-47654-2012<br />

MT-0818-2004<br />

Fabius® plus<br />

Fabius® plus XL<br />

Fabius® Tiro<br />

D-12281-2011<br />

MT-6421-2008<br />

D-7656-2010<br />

Fabius® GS premium<br />

Primus®<br />

Apollo®<br />

D-64715-2012<br />

D-7116-2011<br />

D-64716-2012<br />

Primus® Infinity® Empowered<br />

Perseus® A500<br />

Zeus® Infinity® Empowered


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 29<br />

MONIT<strong>OR</strong>ING & IACS<br />

D-90837-2013<br />

D-19739-2009<br />

Dräger portfolio<br />

Infinity® Delta<br />

Provide continuous monitoring and the same<br />

bedside level of care during transport<br />

Infinity® Acute Care System monitoring solution<br />

Created to meet the needs of all care areas – both<br />

at bedside and during transport<br />

VAP<strong>OR</strong>IZER AND SMARTPILOT® VIEW<br />

MT-2295-2008, D-879-2010<br />

D-7613-2011<br />

Vaporizers<br />

Designed with flexibility in mind – like Dräger<br />

anesthesia workstations<br />

SmartPilot® View<br />

Helps facilitate anesthesia induction, maintenance<br />

and recovery<br />

SPECIALTIES<br />

D-12287-2011<br />

D-9375-2009<br />

MT-1100-2007<br />

Fabius® MRI<br />

MRI-compatible anesthetic management requires a<br />

special room layout plan which con<strong>for</strong>ms to the<br />

patient‘s treatment path<br />

Fabius® Tiro M<br />

Offers the full spectrum of anesthesia ventilation to<br />

military anesthesiologists/cRNAs in the field<br />

The Surgical Display Controller enables you to<br />

display patient vital sign in<strong>for</strong>mation on a largescreen<br />

display in the Operating Room


30 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

DRÄGER P<strong>OR</strong>TFOLIO<br />

D-91557-2013<br />

Accessories<br />

Day in, day out in the hospital you are faced with enormous time and cost pressures at the same time<br />

you are taking care of the welfare of your patients. You need technical medical accessories which you<br />

can use to unlock the full potential of your equipment, which work smoothly, guarantee the best possible<br />

care of your patients and help you to improve your processes. In short: accessories you can rely on,<br />

Dräger can supply it <strong>for</strong> you.<br />

SODA LIME<br />

SENS<strong>OR</strong>S<br />

Whether <strong>for</strong> patient monitoring, care and<br />

treatment of neonates, anesthesia, intensive<br />

care, the emergency department or on the<br />

ward: each original accessory from Dräger<br />

doesn't just fulfil all the official quality standards.<br />

We also measure our accessories<br />

against our own strict Dräger quality standards.<br />

MT-2004-2008<br />

MT-2086-2007<br />

E.g. CLIC Absorber<br />

E.g. flow sensor Infinity® ID


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | DRÄGER P<strong>OR</strong>TFOLIO | 31<br />

VENTILATION<br />

D-19281-2009<br />

MT-11164-2006<br />

D-7059-2009<br />

Breathing circuits<br />

Breathing system filters and HMEs<br />

CO 2 cuvettes<br />

D-12465-2014<br />

D-957-2010<br />

D-402-2010<br />

Catheter mounts and airway connectors<br />

Breathing masks<br />

Intubation kits<br />

MONIT<strong>OR</strong>ING<br />

WARD EQUIPMENT<br />

D-32549-2011<br />

D-10282-2011<br />

D-50637-2012<br />

Dräger portfolio<br />

RAIL ACCESS<strong>OR</strong>IES AND<br />

EXAMINATION LIGHTS<br />

E.g. Masimo® Sensors<br />

E.g. medical aspiration<br />

E.g. medical examination light VarioLux®


32 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

W<strong>OR</strong>KPLACE EXAMPLES<br />

Workplace<br />

examples<br />

<strong>for</strong> <strong>Hybrid</strong> <strong>OR</strong><br />

D-443-2014


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | W<strong>OR</strong>KPLACE EXAMPLES | 33<br />

Workplace examples <strong>for</strong> the <strong>Hybrid</strong> <strong>OR</strong><br />

The following pages give an idea about the number of different<br />

workplace variants.<br />

Workplace examples<br />

The following pages show typical solutions <strong>for</strong><br />

various types of workplaces. They can be used as<br />

a starting point <strong>for</strong> new design concepts based on<br />

customer needs.<br />

Combine elements of two or more examples to<br />

develop the best possible solution <strong>for</strong> your client.


34 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

W<strong>OR</strong>KPLACE EXAMPLES<br />

Supply units<br />

ANESTHESIA<br />

D-90855-2013<br />

D-90854-2013<br />

D-90853-2013<br />

AN-CSU with lifting arm with docked anesthesia<br />

device, monitoring and infusion (docking via<br />

equipment holder or MediaDocking)<br />

AN-CSU with media head and tubes <strong>for</strong> shelves,<br />

monitoring and infusion pumps<br />

AN-CSU with long column <strong>for</strong> shelves and<br />

infusion pumps. The anesthesia device is<br />

placed beside the supply unit<br />

DOCKING<br />

D-85706-2013<br />

Equipment holder <strong>for</strong> docking carts or anesthesia devices with<br />

magnetic docking control<br />

D-18338-2010<br />

Equipment holder <strong>for</strong> docking carts and anesthesia devices with<br />

automatic connection of all media via special MediaDocking interface


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | W<strong>OR</strong>KPLACE EXAMPLES | 35<br />

SURGICAL W<strong>OR</strong>KPLACE<br />

Workplace examples<br />

D-92502-2013<br />

D-90852-2013<br />

CSU with lifting arm, short column and shelf<br />

CSU with long column and three shelves<br />

MT-221-2001<br />

D-12307-2011<br />

CSU with lifing arm, long column, MediaDocking<br />

and docked MovaCart<br />

CSU with media head and tubes <strong>for</strong> shelves and<br />

infusion pumps


36 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

W<strong>OR</strong>KPLACE EXAMPLES<br />

DISPLAY HOLDER<br />

D-57969-2012<br />

Multi display holder <strong>for</strong> up to 8 displays or one<br />

large display (60" screen size)<br />

D-16304-2009<br />

D-90843-2013<br />

D-90844-2013<br />

Short column with four separate display arms<br />

Display arm on central axis<br />

<strong>OR</strong> LIGHTS<br />

D-449-2014<br />

Single light head on central axis<br />

Double light combination with integrated HD-camera<br />

D-103620-2013<br />

Double light combination with display arm, without camera


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | W<strong>OR</strong>KPLACE EXAMPLES | 37<br />

ANESTHESIA DEVICES<br />

D-35680-2011<br />

D-85719-2013<br />

Primus® Infinity® Empowered on CSU. Connection via standard docking or<br />

MediaDocking (also as mobile version available)<br />

Perseus® A500 ceiling mount. Ergonomic anesthesia workstation<br />

with integrated remote control <strong>for</strong> ceiling supply unit<br />

D-7118-2011<br />

Workplace examples<br />

D-64716-2012<br />

Perseus® A500. Mobile flexible positioning of monitors and infusion pumps<br />

Zeus®


38 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

General<br />

planning<br />

MT-5479-2008


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 39<br />

General planning<br />

Learn more about planning a <strong>Hybrid</strong> <strong>OR</strong>.<br />

<strong>Planning</strong> a <strong>Hybrid</strong> <strong>OR</strong> is a complex and technically<br />

challenging process. This chapter will address the<br />

many questions encountered when designing a<br />

new <strong>OR</strong>.<br />

An intimate knowledge of the Dräger product<br />

portfolio and a thorough understanding of<br />

customer needs are vital prerequisites <strong>for</strong> success.<br />

General planning


40 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

General planning<br />

It is important to keep the following in mind:<br />

CEILING SUPPLY UNITS<br />

– Which anesthesia device (lifting or mobile version)?<br />

– Which surgical devices have to be placed<br />

(size, weight, media connections)?<br />

– Is a cart (MovaCart) in use which could be docked<br />

at the supply unit?<br />

– Are there infusion pumps which have to be mounted?<br />

– What is the most ergonomic placement of devices?<br />

– Select a long or short column/head/equipment rack<br />

(e.g. AN-device under or in front column)<br />

– Select an arm system (where must the supply unit to<br />

be placed, where are parking the positions?)<br />

– Select height adjustable or non-adjustable system<br />

(e.g. different staff and heights)<br />

– Select workplace components (shelves, infusion poles)<br />

– Select handles/grips <strong>for</strong> brakes/lift (from where will<br />

the units be positioned? back, front)<br />

– Select cable management (are many cables and hoses to be<br />

expected? How can they be managed? Cable boxes,<br />

cable holder, channels?)<br />

CEILING MOUNT<br />

– Design the ceiling fixture <strong>for</strong> max. load capacity (upgradeability)<br />

– Select a uni-flange <strong>for</strong> possible double CSU (upgradeability)<br />

– Design of double CSU: clarify dead swivel range<br />

of arm system > long distance tubes on rear or front side<br />

– Consider a second anesthesia CSU <strong>for</strong> TIVA<br />

(Total intravenous Anesthesia) or infusion management<br />

– Possible parking positions <strong>for</strong> supply units <strong>for</strong> <strong>OR</strong> change<br />

> stops in arm systems have to be set accordingly<br />

– For MediaDocking: The column has to be equipped with the same<br />

media outlets. If a replacement anesthesia device is necessary<br />

hoses and cables must be available to ensure media supply<br />

– Consider possible collisions of pendants with air flow ceiling<br />

curtains or other interior fixtures<br />

– Consider space (clearance height) under arm systems<br />

(arm/motor hood) and grips of <strong>OR</strong> lights, space under columns<br />

<strong>for</strong> cleaning or further devices such as patient warmer or<br />

suction systems<br />

<strong>OR</strong> LIGHTS/CAMERAS/MONIT<strong>OR</strong>S<br />

– How many light heads are required?<br />

– Which size is necessary?<br />

– Do you have a central axis?<br />

(is it possible? movement of C-Bow)<br />

or a separate mounting on two sides?<br />

– Do you need a third light at foot end?<br />

(e.g. <strong>for</strong> vein harvesting)<br />

– Do you need a small examination light?<br />

(e.g. preparation of catheter)<br />

– Do you need an integrated camera or external camera?<br />

– How will the lights be controlled?<br />

(at cardanic, wall control panel, remote control, touch screen<br />

(integrated <strong>OR</strong>))<br />

– Where will displays be placed?<br />

(size and number is important)<br />

– Select a display holder<br />

(e.g. Pendula, display holder at central axis or holder<br />

at supply unit)<br />

D-7118-2011


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 41<br />

General planning<br />

D-64683-2012<br />

<strong>Planning</strong> an anesthesia workplace<br />

ELEMENTS OF AN ANESTHESIA<br />

W<strong>OR</strong>KPLACE<br />

– Anesthesia device (mobile or at CSU)<br />

– Infusion pumps (at CSU or AN-device, separate)<br />

– Anesthesia supply unit<br />

– Anesthesia trolley<br />

– Blood gas analyser<br />

– Cellsaver<br />

– Sonography device<br />

– Space, about 2 x 4 m<br />

– Must be easily accessible and an ergonomic operation<br />

of equipment must be ensured. Specify any meaningful parking<br />

position <strong>for</strong> angiography system<br />

– Standard hose lengths up to 3 m, special lengths on request<br />

MONIT<strong>OR</strong>ING/ANESTHESIA/IT<br />

– Different workstation configurations are possible<br />

(especially with Dräger Perseus A500)<br />

– Position of control cockpit has to be clarified<br />

– Position of patient monitoring has to be clarified<br />

– Position of IT portal has to be clarified<br />

– Position of infusion pumps has to be clarified<br />

– Optimize workplace <strong>for</strong> connection to ceiling supply unit,<br />

e.g. select shelf, drawer, small appliances rod


42 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 1<br />

Siemens – Artis zee floor arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display boom


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 43<br />

This setup is optimized <strong>for</strong> a floor mounted C-Bow system. All ceiling fixtures are out of the moving range of the C-Bow.<br />

It is possible to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table.<br />

1. ANESTHESIA<br />

A double ceiling mount is selected to attach<br />

an X-Ray protection shield and the swiveling<br />

anesthesia supply unit. The anesthesia device<br />

stands in front of or beneath the supply unit.<br />

The supply unit has a long column. On this<br />

column, a shelf and an infusion pole is mounted.<br />

Additionally, there are two integrated<br />

cable channels at the front side of the column<br />

<strong>for</strong> storing cables and hoses.<br />

Devices at supply unit<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Defibrillator<br />

Infusions (or at AN-device)<br />

Additional devices supplied by unit<br />

Anesthesia device<br />

Blood gas analysis<br />

Sonographer<br />

Cell saver<br />

Endotracheal aspiration (often at AN-device)<br />

Further infusions<br />

Patient warmer<br />

2. CARDIO<br />

There is a double ceiling mount to attach a<br />

multi display holder and a supply unit <strong>for</strong> cardio.<br />

The display holder can carry 8 displays<br />

(up to 21"). The cardio supply unit is a small<br />

liftable column with one shelf.<br />

Devices at supply unit<br />

Monitoring<br />

Additional devices supplied by unit<br />

Heart lung machine HLM<br />

Hypothermia device<br />

3. SURGERY<br />

There is a triple ceiling mount to attach an<br />

X-Ray protection shield, multi display holder<br />

and a supply unit <strong>for</strong> surgery. The display<br />

holder can carry 8 displays (up to 21"). The<br />

surgery supply unit is a long, liftable column<br />

with four shelves. For storing cables and<br />

hoses, there are two cable channels at the<br />

front of the column.<br />

Devices at supply unit<br />

HF surgery device<br />

ECG<br />

Additional devices supplied by unit<br />

Surgical suction device<br />

Contrast agent injector<br />

4. <strong>OR</strong> LIGHTS<br />

A double light solution is optimal. There is a<br />

main light (160.000 lux) and a satellite<br />

(110.000 lux). Optionally, it is possible to<br />

attach a further separate ceiling mount at the<br />

foot end <strong>for</strong> a third light head (e.g. <strong>for</strong> vein harvesting).<br />

General planning


44 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 2<br />

Siemens – Artis zee ceiling arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display boom


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 45<br />

This setup is optimated <strong>for</strong> a ceiling mounted C-Bow system. All ceiling fixtures are out of the moving range of the C-Bow.<br />

It is not possbile to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. Because of the moving range of the C-Bow it is<br />

necessary to have fixations <strong>for</strong> the <strong>OR</strong> lights at the sides. The light heads need long swivel arms to reach the operation field.<br />

5. SURGERY AND CARDIO<br />

There is a double ceiling mount to attach<br />

two supply units <strong>for</strong> surgery and cardio. The<br />

surgery supply unit is a long, liftable column<br />

with four shelves. For storing cables and<br />

hoses, there are two cable channels at the<br />

front of the column. The cardio supply unit is<br />

a small, liftable column with four separate<br />

swiveling display arms (load capacity <strong>for</strong><br />

each arm: 15 kg).<br />

SURGERY<br />

Devices at supply unit<br />

HF surgery device<br />

ECG<br />

CARDIO<br />

Devices at supply unit<br />

Displays (4 x)<br />

Additional devices supplied by unit<br />

Surgical suction device<br />

Contrast agent injector<br />

Additional devices supplied by unit<br />

Heart lung machine HLM<br />

Hypothermia device<br />

6. ANESTHESIA<br />

A triple ceiling mount is selected to attach an<br />

X-Ray protection shield, the liftable anesthesia<br />

supply unit and long swivel arm <strong>for</strong> the light<br />

head (satellite: 110.000 lux). The anesthesia<br />

device is lifted and docked by the supply unit.<br />

The supply unit has a long column. On this<br />

column, a shelf and an infusion pole are<br />

mounted. Additionally, there are two integrated<br />

cable channels at the front side of the<br />

column <strong>for</strong> storing cables and hoses.<br />

Devices at supply unit<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Defibrillator<br />

Infusions (or at AN-device)<br />

Additional devices supplied by unit<br />

Anesthesia device<br />

Blood gas analysis<br />

Sonographer<br />

Cell saver<br />

Endotracheal aspiration (often at AN-device)<br />

Further infusions<br />

Patient warmer<br />

7. DISPLAY HOLDER AND <strong>OR</strong> LIGHT<br />

To attach the display holder and the <strong>OR</strong> light,<br />

a double ceiling mount is used. The display<br />

holder can hold up to 8 displays (size: up to<br />

21"). The light head (160.000 lux) is brought<br />

over the operating field with a long swivel arm.<br />

General planning


46 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 3<br />

Siemens – Artis zee ceiling arrangement – supply unit<br />

MediaDocking arrangement with <strong>OR</strong> lights and display boom


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 47<br />

This setup is optimized <strong>for</strong> a ceiling-mounted C-Bow system. All ceiling fixtures are out of the moving range of the C-Bow.<br />

It is not possible to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. Because of the moving range of the C-Bow, it is<br />

necessary to attach mounts <strong>for</strong> the <strong>OR</strong> lights on the sides. The light heads require long swivel arms to reach the operating<br />

field. The difference between solution 2 and 3 involves the docking of the anesthesia device and a MovaCart at the surgery<br />

supply unit. The supply units <strong>for</strong> surgery should have the same media outlets to enable rapid switching between anesthesia<br />

and surgery. This ensures a high degree of flexibility.<br />

12. ANESTHESIA<br />

A triple ceiling mount is selected to attach an<br />

X-Ray protection shield, the liftable anesthesia<br />

supply unit and long swivel arm <strong>for</strong> light head<br />

(satellite: 110.000 lux). The anesthesia device<br />

is lifted and docked to the supply unit (via<br />

MediaDocking). The supply unit has a long<br />

column. At this column an infusion pole is<br />

mounted.<br />

Devices at supply unit<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Defibrillator<br />

Infusions (or at AN-device)<br />

Additional devices supplied by unit<br />

Anesthesia device<br />

Blood gas analysis<br />

Sonographer<br />

Cell saver<br />

Endotracheal aspiration (often at AN-device)<br />

Further infusions<br />

Patient warmer<br />

13. SURGERY AND CARDIO<br />

There is a double ceiling mount to attach<br />

two supply units <strong>for</strong> surgery and cardio. The<br />

surgery supply unit is a long, liftable column<br />

with MediaDocking to lift a Mova-Cart<br />

(trolley with 4 shelves, 1 drawer). The cardio<br />

supply unit is a small liftable column with<br />

four separate swiveling display arms (load<br />

capacity <strong>for</strong> each arm: 15 kg).<br />

SURGERY<br />

Devices at supply unit<br />

HF surgery device<br />

ECG<br />

CARDIO<br />

Devices at supply unit<br />

Displays (4 x)<br />

Additional devices supplied by unit<br />

Surgical suction device<br />

Contrast agent injector<br />

Additional devices supplied by unit<br />

Heart lung machine HLM<br />

Hypothermia device<br />

7. DISPLAY HOLDER AND <strong>OR</strong> LIGHT<br />

For placing the display holder and the <strong>OR</strong><br />

light, a double ceiling mount is used. The<br />

display holder can carry 8 single displays<br />

(size: up to 21"). The light head (160.000 lux)<br />

is brought over the operating field by a long<br />

swivel arm.<br />

General planning


48 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 4<br />

Siemens – Artis zeego 30° arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display boom


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 49<br />

This setup is optimized <strong>for</strong> a floor-mounted multi-axis C-Bow system 30° arrangement. All ceiling fixtures are out of the<br />

moving range of the C-Bow. Here, it is possible to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. In this layout there is<br />

a third light head at the foot end. The supply units <strong>for</strong> surgery should have the same media outlets to enable rapid switching<br />

between anesthesia and surgery. This ensures a high degree of flexibility.<br />

8. ANESTHESIA AND CARDIO<br />

A triple ceiling mount is selected to attach<br />

an X-Ray protection shield, the liftable anesthesia<br />

supply unit and long swivel arm <strong>for</strong><br />

light head (satellite: 110.000 lux). The anesthesia<br />

device is lifted and docked to the supply<br />

unit (via MediaDocking). The supply unit<br />

has a long column. At this column, an infusion<br />

pole is mounted.<br />

Devices at supply unit<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Defibrillator<br />

Infusions (or at AN-device)<br />

CARDIO<br />

Devices at supply unit<br />

Displays (4 x)<br />

Additional devices supplied by unit<br />

Anesthesia device<br />

Blood gas analysis<br />

Sonographer<br />

Cell saver<br />

Endotracheal aspiration (often at AN-device)<br />

Further infusions<br />

Patient warmer<br />

Additional devices supplied by unit<br />

Heart lung machine HLM<br />

Hypothermia device<br />

9. <strong>OR</strong> LIGHT AND X-RAY PROTECTION<br />

For the <strong>OR</strong> light, a double ceiling fixation at<br />

the foot end <strong>for</strong> a third <strong>OR</strong> light and an X-Ray<br />

protection shield is used. The light head<br />

(110.000 lux) is brought over the operating<br />

field by a long swivel arm.<br />

10. SURGERY<br />

There is a single ceiling mount to attach the<br />

surgery supply unit. This unit is a long, liftable<br />

column with MediaDocking to lift a MovaCart<br />

(trolley with 4 shelves, 1 drawer).<br />

SURGERY<br />

Devices at supply unit<br />

HF surgery device<br />

ECG<br />

Additional devices supplied by unit<br />

Surgical suction device<br />

Contrast agent injector<br />

11. DISPLAY HOLDER<br />

A separate ceiling mount is used <strong>for</strong> placing<br />

the display holder. The display holder can<br />

carry a single display (size: 60”).<br />

General planning


50 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 5<br />

Siemens – Artis zeego parallel arrangement – supply unit<br />

MediaDocking arrangement with <strong>OR</strong> lights and display<br />

boom


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 51<br />

This setup is optimized <strong>for</strong> a floor-mounted, multi-axis C-Bow system (parallel arrangement) All ceiling fixtures are out of the<br />

moving range of the C-Bow. It is possible to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. Here, a symmetric layout with<br />

side-mounted light heads was chosen. The supply units <strong>for</strong> surgery should have the same media outlets to enable rapid<br />

switching between anesthesia and surgery. This ensures a high degree of flexibility.<br />

14. X-RAY PROTECTION<br />

For the X-Ray protection shield, there are two<br />

single ceiling mounts at the head and foot<br />

ends.<br />

15. ANESTHESIA/CARDIO<br />

A double ceiling mount is selected to attach<br />

a liftable anesthesia supply unit and a multi<br />

display holder. The anesthesia device is lifted<br />

and docked to the supply unit (via Media-<br />

Docking). The supply unit has a long column.<br />

On this column, an infusion pole is mounted.<br />

This supply unit is also used as a cardio unit<br />

to supply the Hlmor hypothermia device. The<br />

display holder can carry 8 single displays<br />

(size: up to 21").<br />

Devices at supply unit<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Defibrillator<br />

Infusions (or at AN-device)<br />

Additional devices supplied by unit<br />

Anesthesia device<br />

Blood gas analysis<br />

Sonographer<br />

Cell saver<br />

Endotracheal aspiration (often at AN-device)<br />

Further infusions<br />

Patient warmer<br />

Heart lung machine HLM<br />

Hypothermia device<br />

16. SURGERY<br />

There is a double ceiling mount to attach the<br />

surgery supply unit and a multi display holder.<br />

This unit is a long, liftable column with<br />

MediaDocking to lift a MovaCart (trolley with<br />

4 shelves, 1 drawer). The display holder can<br />

carry 8 single displays (size: up to 21").<br />

SURGERY<br />

Devices at supply unit<br />

HF surgery device<br />

ECG<br />

Additional devices supplied by unit<br />

Surgical suction device<br />

Contrast agent injector<br />

General planning


52 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 6<br />

Philips – Allura FD 20 ceiling arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display booms


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 53<br />

This setup is optimized <strong>for</strong> a ceiling mounted C-Bow system (basic arrangement) All ceiling fixtures are out of the moving<br />

range of the C-Bow. It is not possible to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. There<strong>for</strong>e you need to have long<br />

swivel arms <strong>for</strong> the <strong>OR</strong> lights to reach the operating field. This layout offers a basic setup which can be upgraded with further<br />

supply units if needed. X-Ray protection shields are not shown in this layout. These can be mounted at the ceiling or mobile lead<br />

glass walls can be used.<br />

17. ANESTHESIA<br />

A single ceiling mount is selected to attach a<br />

liftable anesthesia supply unit. The anesthesia<br />

device is lifted and docked to the supply unit.<br />

The supply unit has a long column. On this<br />

column, an infusion pole is mounted.<br />

Devices at supply unit<br />

Anesthesia device<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Endotracheal aspiration<br />

Additional devices supplied by unit<br />

Cell saver<br />

Blood gas analysis<br />

Sonographer<br />

Further infusions<br />

Patient warmer<br />

18. DISPLAY HOLDER AND <strong>OR</strong> LIGHT<br />

For placing the display holder and the <strong>OR</strong><br />

light, a double ceiling mount is used. The<br />

display holder can carry 8 single displays<br />

(size: up to 21”). The light head (160.000<br />

lux) is brought over the operating field by a<br />

long swivel arm.<br />

19. DISPLAY HOLDER AND <strong>OR</strong> LIGHT<br />

For placing the display holder and the <strong>OR</strong><br />

light, a double ceiling mount is used. The<br />

display holder can carry 8 single displays<br />

(size: up to 21”). The light head (110.000<br />

lux) is brought over the operating field by a<br />

long swivel arm.<br />

20. CARDIO<br />

There is a single ceiling mount to attach a<br />

supply unit <strong>for</strong> cardio. The cardio supply unit<br />

is a small liftable column with two separate<br />

swiveling display arms (load capacity <strong>for</strong><br />

each arm: 15 kg) and a shelf.<br />

Devices at supply unit<br />

Displays (2 x)<br />

HF surgery device<br />

Additional devices supplied by unit<br />

Heart lung machine<br />

Hypothermia device<br />

Surgical suction device<br />

Contrast agent injector<br />

General planning


54 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 7<br />

Philips – Allura FD 20 FlexMove arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display booms


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 55<br />

This setup is optimized <strong>for</strong> a ceiling mounted C-Bow system (basic arrangement) All ceiling fixtures are out of the moving range<br />

of the C-Bow. In this configuration we have a FlexMove system. This system has an additional movement range (x/y – movement)<br />

which has to be taken into consideration during planning. For this additional function there are wide rails at the ceiling. It is not<br />

possible to have a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. There<strong>for</strong>e you need to have long swivel arms <strong>for</strong> the <strong>OR</strong> lights to<br />

reach the operating field. This layout offers a basic setup which can be upgraded with further supply units if needed. X-Ray<br />

protection shields are not shown in this layout. These can be mounted at the ceiling or mobile lead glass walls can be used.<br />

19. DISPLAY HOLDER AND <strong>OR</strong> LIGHT<br />

<strong>for</strong> placing the display holder and the <strong>OR</strong> light,<br />

a double ceiling mount is used. The display<br />

holder can carry 8 single displays (size:<br />

up to 21”). The light head (110.000 lux) is<br />

brought over the operating field by a long<br />

swivel arm.<br />

20. CARDIO<br />

There is a single ceiling mount to attach a<br />

supply unit <strong>for</strong> cardio. The cardio supply unit<br />

is a small liftable column with two separate<br />

swiveling display arms (load capacity <strong>for</strong><br />

each arm: 15 kg) and a shelf.<br />

Devices at supply unit<br />

Displays (2 x)<br />

HF surgery device<br />

Additional devices supplied by unit<br />

Heart lung machine<br />

Hypothermia device<br />

Surgical suction device<br />

Contrast agent injector<br />

21. ANESTHESIA<br />

A single ceiling mount is selected to attach a<br />

liftable anesthesia supply unit. The anesthesia<br />

device is lifted and docked to the supply<br />

unit. The supply unit has a long column. On<br />

this column, an infusion pole is mounted.<br />

Devices at supply unit<br />

Anesthesia device<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Endotracheal aspiration<br />

Additional devices supplied by unit<br />

Cell saver<br />

Blood gas analysis<br />

Sonographer<br />

Further infusions<br />

Patient warmer<br />

22. <strong>OR</strong> LIGHT<br />

The light head (160.000 lux) is mounted<br />

separately and is brought over the operating<br />

field by a long swivel arm.<br />

23. DISPLAY HOLDER<br />

For placing the display holder a single<br />

ceiling mount is used. The display holder can<br />

carry 8 single displays (size: up to 21”).<br />

General planning


56 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 8<br />

Philips – Allura FD 20 FlexMove arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display booms


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 57<br />

This setup is optimized <strong>for</strong> a ceiling mounted C-Bow system. All ceiling fixtures are out of the moving range of the C-Bow. In this<br />

configuration we have a FlexMove system. This system has an additional movement range (x/y – movement) which has to be<br />

taken into consideration during planning. For this additional function there are wide rails at the ceiling. It is not possible to have<br />

a central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. There<strong>for</strong>e you need to have long swivel arms <strong>for</strong> the <strong>OR</strong> lights to reach the<br />

operating field. Compared to Solution no. 7 there is an additional supply unit and <strong>OR</strong> light at feet end <strong>for</strong> second surgical team<br />

(e.g. vessel stripping <strong>for</strong> bypasses interventions)<br />

19. DISPLAY HOLDER AND <strong>OR</strong> LIGHT<br />

For placing the display holder and the <strong>OR</strong><br />

light, a double ceiling mount is used. The display<br />

holder can carry 8 single displays (size:<br />

up to 21”). The light head (110.000 lux) is<br />

brought over the operating field by a long<br />

swivel arm.<br />

20. CARDIO<br />

There is a single ceiling mount to attach a<br />

supply unit <strong>for</strong> cardio. The cardio supply unit<br />

is a small liftable column with two separate<br />

swiveling display arms (load capacity <strong>for</strong><br />

each arm: 15 kg) and a shelf.<br />

Devices at supply unit<br />

Displays (2 x)<br />

Additional devices supplied by unit<br />

Heart lung machine<br />

Hypothermia device<br />

Surgical suction device<br />

HF surgery device<br />

22. <strong>OR</strong> LIGHT<br />

The light head (160.000 lux) is mounted<br />

separately and is brought over the operating<br />

field by a long swivel arm.<br />

23. DISPLAY HOLDER<br />

For placing the display holder a single<br />

ceiling mount is used. The display holder can<br />

carry 8 single displays (size: up to 21”).<br />

24. ANESTHESIA<br />

A single ceiling mount is selected to attach<br />

a liftable anesthesia supply unit. The anesthesia<br />

device is lifted and docked to the supply<br />

unit. The supply unit has a long column.<br />

25. SURGERY AND <strong>OR</strong> LIGHT<br />

A double ceiling mount is selected to attach<br />

a liftable supply unit and an <strong>OR</strong> light. The<br />

supply unit has a short thin column and has<br />

one shelf <strong>for</strong> a device. The light head<br />

(110.000 lux) is used by secondary surgical<br />

team.<br />

Devices at supply unit<br />

Anesthesia device<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Endotracheal aspiration<br />

Devices at supply unit<br />

HF surgery device<br />

Additional devices supplied by unit<br />

Cell saver<br />

Blood gas analysis<br />

Sonographer<br />

Further infusions<br />

Patient warmer<br />

Additional devices supplied by unit<br />

Contrast agency injector<br />

Surgical suction device<br />

General planning


58 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Solution 9<br />

Philips – Allura FD 20 FlexMove arrangement – supply unit<br />

arrangement with <strong>OR</strong> lights and display booms


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 59<br />

This setup is optimized <strong>for</strong> a ceiling mounted C-Bow system. All ceiling fixtures are out of the moving range of the C-Bow. In this<br />

configuration we have a FlexMove system. This system has an additional movement range (x/y – movement) which has to be taken<br />

into consideration during planning. For this additional function there are wide rails at the ceiling. It is not possible to have a<br />

central axis <strong>for</strong> <strong>OR</strong> lights over the <strong>OR</strong> table. There<strong>for</strong>e you need to have long swivel arms <strong>for</strong> the <strong>OR</strong> lights to reach the operating<br />

field. This layout can be upgraded later with further supply units if needed. X-Ray protection shields are not shown in this layout.<br />

These can be mounted at the ceiling or mobile lead glass walls can be used. We have two separate fixation points at the ceiling<br />

<strong>for</strong> the operating lights which increases flexibility. Due to positioned display holder at the feet end it’s possible to swop the sides<br />

<strong>for</strong> different interventions.<br />

21. ANESTHESIA<br />

A single ceiling mount is selected to attach a<br />

liftable anesthesia supply unit. The anesthesia<br />

device is lifted and docked to the supply unit.<br />

The supply unit has a long column. On this<br />

column, an infusion pole is mounted.<br />

Devices at supply unit<br />

Anesthesia device<br />

Monitoring (or at AN-device)<br />

IT/Documentation (or at AN-device)<br />

Pacemaker<br />

Endotracheal aspiration<br />

Additional devices supplied by unit<br />

Cell saver<br />

Blood gas analysis<br />

Sonographer<br />

Further infusions<br />

Patient warmer<br />

22. <strong>OR</strong> LIGHT<br />

The light head (160.000 lux) is mounted<br />

separately and is brought over the operating<br />

field by a long swivel arm.<br />

26. CARDIO & INFUSIONS<br />

There is a double ceiling mount to attach a<br />

supply unit <strong>for</strong> cardio and infusions. The<br />

cardio supply unit is a small liftable column<br />

with two separate swiveling display arms<br />

(load capacity <strong>for</strong> each arm: 15 kg). The supply<br />

unit <strong>for</strong> infusions is realized by an horizontal<br />

media head with an equipment rack<br />

below. On this rack are three shelves placed<br />

<strong>for</strong> devices.<br />

Devices at supply unit<br />

CARDIO<br />

Displays (2 x)<br />

INFUSIONS<br />

Defibrillator<br />

HF surgery device<br />

Monitoring<br />

Infusions<br />

Additional devices supplied by unit<br />

Heart lung machine<br />

Hypothermia device<br />

Surgical suction device<br />

Contrast agent injector<br />

Further infusions<br />

27. DISPLAY HOLDERS<br />

For placing the display holders a double ceiling<br />

mount is used. The display holder can<br />

carry 8 single displays (size: up to 21”) or<br />

one large display. The double ceiling mount<br />

enables a side change by the displays in<br />

case of changing interventions or setups.<br />

28. <strong>OR</strong> LIGHT<br />

The light head (110.000 lux) is mounted<br />

separately and is brought over the operating<br />

field by a long swivel arm.<br />

General planning


60 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

CAD Drawings – Configuration 1<br />

In this chapter, all configurations shown in “Workplace Solutions” are listed.<br />

The numbers correspond to the numbers in the ground plans.<br />

Movita - Radiation Protection


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 61<br />

Configuration 2<br />

General planning<br />

Movita - Pendula Cardiotechnology Type


62 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 3<br />

Movita - Pendula - Radiation Protect


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 63<br />

Configuration 4<br />

General planning<br />

Polaris® 500/700


64 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 5<br />

Movita - Cardiotechnology Type


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 65<br />

Configuration 6<br />

General planning<br />

Movita - Cardiotechnology Type


66 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 7<br />

Pendula 60" - Polaris® 700


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 67<br />

Configuration 8<br />

General planning<br />

Movita - Forta Cardiotechnology Type


68 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 9<br />

Polaris® 500 - Radiation Protection


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 69<br />

Configuration 10<br />

General planning<br />

Forta MD


70 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 11<br />

Pendula 60"


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 71<br />

Configuration 12<br />

General planning<br />

Forta MD - Polaris® 500 - Radiation Protection


72 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 13<br />

Movita - Forta Cardiotechnology Type


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 73<br />

Configuration 14<br />

General planning<br />

Radiation Protection


74 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 15<br />

Pendula - Forta MD - Polaris® 700


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 75<br />

Configuration 16<br />

General planning<br />

Pendula - Forta MD - Polaris® 500


76 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 17<br />

Movita 10 (Lift)


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 77<br />

Configuration 18<br />

General planning<br />

Pendula 60" - Polaris® 750


78 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 19<br />

Pendula 19" - Polaris® 500


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 79<br />

Configuration 20<br />

General planning<br />

Movita 05 (Lift)


80 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 21<br />

Movita 10 (Lift)


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 81<br />

Configuration 22<br />

General planning<br />

Polaris® 750


82 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 23<br />

Pendula 60"


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 83<br />

Configuration 24<br />

General planning<br />

Movita 10 (Lift)


84 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 25<br />

Agila 05 (Lift) - Polaris® 500


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 85<br />

Configuration 26<br />

General planning<br />

Movita 05 (Lift) - Movita AK (Lift)


86 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> |<br />

GENERAL PLANNING<br />

Configuration 27<br />

Pendula 60" - Pendula 19"


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | GENERAL PLANNING | 87<br />

Configuration 28<br />

General planning<br />

Polaris® 500


88 |<br />

PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong>


PLANNING DOCUMENTS F<strong>OR</strong> HYBRID <strong>OR</strong> | CONTACT | 89<br />

Contact<br />

For planners and architects:<br />

CONTACT F<strong>OR</strong> PROJECTS AND TECHNICAL PLANNING:<br />

Marco Patzer<br />

Project Engineer<br />

+49 451 882 2419<br />

marco.patzer@draeger.com<br />

Sebastian Rahn<br />

Project Engineer<br />

+49 451 882 2446<br />

sebastian.rahn@draeger.com<br />

WEB:<br />

www.draeger.com/planning<br />

Subject to change.<br />

Not all products are available in all parts of the world.<br />

More in<strong>for</strong>mation: www.draeger.com


C<strong>OR</strong>P<strong>OR</strong>ATE HEADQUARTERS<br />

Drägerwerk AG & Co. KGaA<br />

Moislinger Allee 53–55<br />

23558 Lübeck, Germany<br />

www.draeger.com<br />

Manufacturer:<br />

Dräger Medical GmbH<br />

Moislinger Allee 53–55<br />

23558 Lübeck, Germany<br />

As of August 2015:<br />

Dräger Medical GmbH changes<br />

to Drägerwerk AG & Co. KGaA.<br />

REGION EUROPE CENTRAL<br />

AND EUROPE N<strong>OR</strong>TH<br />

Dräger Medical GmbH<br />

Moislinger Allee 53–55<br />

23558 Lübeck, Germany<br />

Tel +49 451 882 0<br />

Fax +49 451 882 2080<br />

info@draeger.com<br />

REGION EUROPE SOUTH<br />

Dräger Médical S.A.S.<br />

Parc de Haute Technologie d’Antony 2<br />

25, rue Georges Besse<br />

92182 Antony Cedex, France<br />

Tel +33 1 46 11 56 00<br />

Fax +33 1 40 96 97 20<br />

dlmfr-contact@draeger.com<br />

REGION MIDDLE EAST, AFRICA<br />

Dräger Medical GmbH<br />

Branch Office<br />

P.O. Box 505108<br />

Dubai, United Arab Emirates<br />

Tel +971 4 4294 600<br />

Fax +971 4 4294 699<br />

contactuae@draeger.com<br />

REGION ASIA / PACIFIC<br />

Draeger Medical<br />

South East Asia Pte Ltd.<br />

25 International Business Park<br />

#04-27/29 German Centre<br />

Singapore 609916, Singapore<br />

Tel +65 6572 4388<br />

Fax +65 6572 4399<br />

asia.pacific@draeger.com<br />

REGION CENTRAL<br />

AND SOUTH AMERICA<br />

Dräger Panama Comercial S. de R.L.<br />

Complejo Business Park,<br />

V tower, 10th floor<br />

Panama City<br />

Tel +507 377 9100<br />

Fax +507 377 9130<br />

contactcsa@draeger.com<br />

90 68 051 | 1411-2 | Communications & Sales Marketing | AW | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2014 Drägerwerk AG & Co. KGaA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!