access control<br />

<strong>EZ</strong> I/O <strong>Controller</strong>s<br />

Overview<br />

<strong>EZ</strong> I/O controllers provide eight supervised alarm inputs and<br />

four change-over relay outputs. A tamper input is also included<br />

for the panel enclosure.<br />

<strong>EZ</strong> I/O <strong>Controller</strong>s – (IP)<br />

Features<br />

• 8 supervised alarm inputs<br />

• 4 change-over relay outputs<br />

• IP and RS485 versions available<br />

• Power over Ethernet (PoE) Plus supported<br />

• Panel tamper protection<br />

• Real-time processing at the controller<br />

• On-board information LEDs<br />

• Individual battery back-up<br />

• Data configuration retained for up to 100Hrs. after<br />

main battery exhaustion<br />

• Up to 4,000 event buffer if off-line<br />

• No system limit for the number of controllers<br />

IP I/O controllers employ their own IP address and connect<br />

directly to the <strong>SAT</strong>EON PC network via an IP switch. No other<br />

connection is required in order to work with <strong>SAT</strong>EON.<br />

PoE Plus is supported by including a Grosvenor Technology<br />

PoE splitter which includes individual fuses for battery overload<br />

and battery charging circuits.<br />

There is no limit to the number of IP controllers that can connect<br />

to a <strong>SAT</strong>EON system.<br />

<strong>EZ</strong> I/O <strong>Controller</strong>s – (RS485)<br />

<strong>EZ</strong> RS485 I/O controllers can be connected in-line with up to<br />

thirty-two controller nodes to form a <strong>SAT</strong>EON ‘Comms Line’.<br />

<strong>EZ</strong> RS485 controllers are interconnected via a 2-wire Comms<br />

Line (2-wire plus braid), and connect to the <strong>SAT</strong>EON PC<br />

network via an IP Line Header.<br />

There is no limit to the number of RS485 Comms Lines that can<br />

be connected to a <strong>SAT</strong>EON system.<br />

Power Supply and Enclosures<br />

<strong>EZ</strong> controllers install into a Grosvenor Technology enclosure<br />

or other equivalent of your choice. The Grosvenor enclosure<br />

includes an integral 2.5A PSU of which 2A is available for<br />

peripherals.<br />

Grosvenor Technology Ltd, Millars Three, Southmill Road, Bishop’s Stortford, Herts, CM23 3DH. UK<br />

Tel: +44 (0)1279 838000 Email: sales@grosvenortechnology.co.uk Fax: +44 (0)1279 504776<br />

www.grosvenortechnology.co.uk<br />

<strong>DS</strong>-<strong>SAT</strong>-<strong>003</strong>/01 <strong>SAT</strong>EON <strong>EZ</strong> I/O <strong>Controller</strong>s


access control<br />

<strong>EZ</strong> I/O <strong>Controller</strong>s<br />

Dimensions (H x W x D)<br />

105mm x 129mm x 37mm H, W, D<br />

(board only)<br />

381 mm x 275 mm x 75 mm H, W, D<br />

(with <strong>EZ</strong>-ENC-2A-230V enclosure)<br />

Weight<br />

162g (IP board only)<br />

156g (RS485 board only)<br />

2.5 kg (<strong>EZ</strong>-ENC-2A-230V enclosure)<br />

Operating Temperatures<br />

0°C to 50°C<br />

Power Requirement<br />

230V AC 50 Hz 84VA (IP controller)<br />

230V AC 50Hz 24VA (RS485 controller):<br />

Battery Back-Up (12V 7Ah)<br />

Battery duration will depend upon the type of controller<br />

and the <strong>com</strong>bined rating of peripherals connected. A 7Ah<br />

battery will typically provide up to 4 hours reserve, and in<br />

addition, the <strong>EZ</strong> board will maintain its configuration for up<br />

to 100 hours after battery exhaustion.<br />

Panel Tamper<br />

Included<br />

Communication (IP I/O <strong>Controller</strong>)<br />

RJ45 Ethernet 10/100 BASE-T<br />

Communication Speed (IP I/O <strong>Controller</strong>)<br />

10/100 Mbps<br />

TCP/IP (IP I/O <strong>Controller</strong>)<br />

DHCP supported<br />

Optional Encryption (IP I/O <strong>Controller</strong>)<br />

Rijndael Advanced Encryption Standard (AES)<br />

Certifi cation<br />

BS EN 50133-1 + A1 1997 – Emissions and immunity<br />

standard for access control systems<br />

BS EN 55022 class B 1998 – Emissions standard for<br />

information technology equipment<br />

BS EN 50133-1 + A1 1997 – Immunity standard for access<br />

control systems<br />

BS EN 61000-4-2 1995 – ESD requirements<br />

BS EN 61000-4-3 + A1 2006 – Radiated susceptibility<br />

BS EN 61000-4-4 1995 – Electrical fast transient burst<br />

requirements<br />

BS EN 61000-4-5 1995 – Surges requirements<br />

BS EN 61000-4-6 1996 – Conducted susceptibility<br />

BS EN 61000-4-11 1994 – Voltage dips and interruptions<br />

Following the provisions of EU EMC Directives 89/336/EEC<br />

and 92/31/EEC<br />

Ordering Information<br />

<strong>EZ</strong>-<strong>SAT</strong>-<strong>IO</strong>12-E<br />

IP I/O <strong>Controller</strong> - Board Only<br />

<strong>EZ</strong>-<strong>SAT</strong>-<strong>IO</strong>12-485<br />

RS485 I/O <strong>Controller</strong> - Board Only<br />

<strong>EZ</strong>-ENC-2A-230V<br />

Enclosure/Panel c/w 230V 2A Mains PSU<br />

<strong>EZ</strong>-LH-ENET-485<br />

IP Line Header for RS485 Comms Line<br />

<strong>EZ</strong>-POE-PSU<br />

PoE Splitter c/w fused circuits for lock (not used with I/O<br />

board), battery overload and battery charging<br />

Communication (RS485 I/O <strong>Controller</strong>)<br />

2-wire twisted pair RS485. For long runs or in harsh<br />

electrical environments use screened or braided pair.<br />

Communication Speed (RS485 I/O <strong>Controller</strong>)<br />

19.2 kbaud<br />

Firmware Flash Memory<br />

Dual 512 Kbit<br />

RAM Memory<br />

4 Mbit.<br />

Grosvenor Technology Ltd, Millars Three, Southmill Road, Bishop’s Stortford, Herts, CM23 3DH. UK<br />

Tel: +44 (0)1279 838000 Email: sales@grosvenortechnology.co.uk Fax: +44 (0)1279 504776<br />

www.grosvenortechnology.co.uk<br />

<strong>DS</strong>-<strong>SAT</strong>-<strong>003</strong>/01 <strong>SAT</strong>EON <strong>EZ</strong> I/O <strong>Controller</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!