Reliability Tests: Life Test<br />

The life test is designed to demonstrate the MTBF evaluation. Every time the test<br />

is stopped to change parameter, components etc. you have to start from the<br />

beginning.<br />

• 55 inverters and 3 CDDs<br />

• Connected to 59.2Vdc (Vmp = 51.5Vdc), Imp = 6.2A<br />

• AC out put 230VAC, 50Hz grid<br />

• Constant 55°C ambient temperature<br />

• All inverters producing maximum continuous output power<br />

No failures recorded<br />

Date<br />

Number of DUT<br />

Hours worked<br />

(Each DUT)<br />

MTBF<br />

Demonstrated<br />

(hours)<br />

Total On/Off cycles Number of failure<br />

Life Test Status<br />

19/09/2012 - 19/10/2012 18 456:00:00 101267 456 0 20.50%<br />

22/10/2012 - 04/11/2012 55 278:16:49 289908 278 0 59.00%<br />

04/11/2012 - 15/11/2012 55 264:00:00 469050 542 0 95.00%<br />

15/11/2012 - 22/11/2012 55 175:27:05 587799 717 0 119.09%<br />

22/11/2012 - 28/11/2012 55 142:24:09 687548 860 0 138.75%